Fuse
Panels- rectifiers-Hendry AC Distribution Unit- Hendry Fuse Panels-Hendry Distribution
Panels- Hendry Rectifiers
American
Tech Supply carries a complete line fuse panels and rectifiers including Hendry
AC Distribution Panels, Hendry fuse panels, Hendry rectifiers for very application
from the telephone closet to the network room to your co-location data center.
The AC Distribution unit utilizes one master circuit breaker and up to five single-
or double-pole circuit breakers. The unit consists of one to five outputs depending
on the number of circuit breakers used. Each breaker position distributes a maximum
output of 14 A, and the panel distributes a maximum current of 80 A. The AC Distribution
unit is rack-mounted in standard 19" or 23" mounting widths
Call
us today for a price quote at (866) 650-DATA
Hendry
AC Distribution Panels- Hendry Rectifiers
Hendry Fuse
Panels
For
power distribution up to 200 Amps. Hendry fuse panels use Type 70, GMT, KTK-type
and TPA fuses and are available with input circuit breakers.
DESCRIPTION
Hendry's
AC Distribution unit is a modular assembly that provides optional AC power distribution
for Hendry or other manufacturers' power systems. The unit is configured for a
110/240 VAC single-phase input.
The
AC Distribution unit utilizes one master circuit breaker and up to five single-
or double-pole circuit breakers. The unit consists of one to five outputs depending
on the number of circuit breakers used. Each breaker position distributes a maximum
output of 14 A, and the panel distributes a maximum current of 80 A. The AC Distribution
unit is rack-mounted in standard 19" or 23" mounting widths.
STANDARD FEATURES
* Circuit Breaker Configuration- One circuit breaker input and one to five circuit
breaker outputs.
* Mounting Adapters- Allows 19" unit to be mounted in
a 23" rack mounting width.
* Highly Reliable Circuitry- MTBF exceeds
200,000 hours.
SPECIFICATIONS
CIRCUIT BREAKERS/UNIT- 6 (max.)
CAPACITY/CIRCUIT BREAKER-
Input- 100 A two-pole; Output- 20 A two-pole
PANEL CAPACITY- 14 A (max.) per
output breaker; 80 A total
OPERATING VOLTAGE- 110/240 VAC or 208 VAC @ 50-60
Hz
ENVIRONMENTAL TEMPERATURE RANGE- -18 to +43° C
INPUT POWER CONNECTION-
#6-0 AWG barrel terminal block
OUTPUT POWER CONNECTION- 3-position Mate-N-Lok
connectors
CHASSIS GROUND CONNECTION- 2 (#10) screws
RACK MOUNTING WIDTH-
19" or 23"
RACK MOUNTING UNIT- 2 RMU (2 RMU also fits 3.50"
space)
WEIGHT- 8.5 lbs
MATERIAL- Cold-rolled steel
FINISH- Telephone
gray, polyurethane, textured powder coating.
*
GR-63-CORE COMPLIANT
* GR-487-CORE COMPLIANT
* GR-1089-CORE COMPLIANT
* UL 1950, UL 50 & UL 94 COMPLIANT
8035
EBE Custom EBE External Battery Enclosure for VRLA Batteries
The
08035 Custom External Battery Enclosure (EBE) for VRLA batteries is designed for
housing valve regulated lead acid battery backup systems in outdoor environments
where dirt, dust, oil, water and other contaminants may be a factor. This lockable
cabinet is ideal for restricted access applications. For added security, all hardware
is internal. Each of the six battery shelves accommodates a single -48 VDC, 90
Amp-hour string of VRLA batteries for up to 540 Amp-hours of backup time. Bus
bars provide a single-point connection to customer equipment. This cabinet is
available with an optional heater and air conditioner which allows for operation
of the batteries in ambient temperatures ranging from -40 to +50 degrees C.
trans.gif
STANDARD FEATURES
* UL and Bellcore Compliant.
* Equivalent NEMA Type 3S on battery enclosure.
* Equivalent NEMA Type 3R on HVAC area.
* Two-point, key- and pad-lockable
latch on front-access door.
* Rubber bulb gasket on all openings.
* Heavy
duty lifting tabs are removable.
* Wind stay on front-access door.
* Vents
allow for hydrogen diffusion.
* Solar shields on sides, rear and top are standard.
* Intrusion alarms are included.
* Dust filters can be removed for cleaning.
* Cable entry system allows watertight configurable seal for cables.
* Order
VRLA battery system separately. Contact Hendry.
* Battery Management is available
with a Hendry power system. Contact Hendry.
8035
EBE Custom EBE External Battery Enclosure for NiCAD Batteries
The
08035 Custom External Battery Enclosure (EBE) for NiCad batteries is designed
for housing nickel-cadmium battery backup systems in environ-ments where dirt,
dust, oil, water and other contami-nants may be a factor. This lockable cabinet
is ideal for restricted access applications. Each of the four battery shelves
accommodates a single -48 VDC, 125 Amp-hour string of NiCad batteries for up to
500 Amp-hours of backup time. NiCad batteries are available with a single-point
watering system and integral flame arrestor for ease of maintenance and protection.
NiCad batteries are designed to operate at nominal temperatures ranging from -20
to +40 degrees C and tolerate extremes to +70 degrees C. Insulation and optional
heaters allow for operation of the system in extreme environments ranging down
to -50 degrees C.
trans.gif
STANDARD FEATURES
* UL and Bellcore Compliant.
* Equivalent NEMA Type 3S on battery enclosure.
* Two-point, key- and pad-lockable latch on front-access door.
* Rubber bulb
gasket on all openings.
* Heavy duty lifting eyes are removable.
* Wind
stay on front-access door.
* Vents allow for hydrogen diffusion.
* Instrusion
alarm is included.
* Dust filter can be removed for cleaning.
* Cable
entry system allows watertight configurable seal for cables.
* Order NiCad
battery system separately. Contact Hendry.
* Battery Management is available
with a Hendry power system. Contact Hendry.
trans.gif
SPECIFICATIONS
FRAME- .187" cold-rolled steel
SHELVES- .120"
cold-rolled steel
HOUSING & DOOR- .125" 5052 aluminum
MAIN ENCLOSURE-
36"W x 30"D x 72"H
INSULATION- 1/4"-thick, foil-faced
foam
FINISH- UV resistant, almond, polyurethane, smooth powder coating
West
Coast (866) 342-3721 ------East
Coast (866) 650-DATA
We