AccuTube® 200/250 µm Rollable Ribbon Indoor/Outdoor Building Cable


Item Number
AccuTube RR Building Cable

Description
AccuTube® 200/250 µm Rollable Ribbon Indoor/Outdoor Building Cable


Applications
Outdoor/Indoor

Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare
Item Number
AccuTube RR Building Cable

Description
AccuTube® 200/250 µm Rollable Ribbon Indoor/Outdoor Building Cable


Applications
Outdoor/Indoor

Cable Weight 634 (kg/km)
Cable Weight 425 (lb/kft)
Storage Temperature -40 to 70 (ºC)
Storage Temperature -40 to 158 (ºF)
Construction Loose Tube
Performance Standard

The AccuTube RR Indoor/Outdoor Building Cable meets all or portions
of Telcordia GR-20 CORE Issue 4 and ANSI/ICEA S-87-640. Dual-rated
cables are UL listed as compliant with NEC Article 770 as Type OFNR.

Fiber Count 1728
Cable Outer Diameter 1 (in)
Cable Outer Diameter 25.4 (mm)
Maximum Long Term Load 1412 (N)
Maximum Long Term Load 333 (lb)
Installation Temperature -20 to 60 (ºC)
Installation Temperature -4 to 140 (ºF)
Operation Temperature -40 to 70 (ºC)
Operation Temperature -40 to 158 (ºF)
Cable Type Rollable Ribbon
Aerial or Underground Underground (Duct)
Maximum Tensile Rating 2670 (N)
Maximum Tensile Rating 600 (lb)
Core Tube 0.28 (Inch)
Core Tube 7.2 (mm)
CPR Rating B2ca-s1a, d0, a1
DoP Lookup ATIO-1728-A-D
Static Condition/Unloaded 10 x OD (in)
Dynamic Condition/Loaded 40 x OD (in)
Storage Coils 40 x OD (in)
Compressive Strength 220 (N/cm max)

Brand

OFS Optics