Features & Benefits
- Reliable network performance: Designed for mission-critical situations that require constant uptime, whether indoor or outside
- Best-in-class system noise immunity: Achieved through outstanding cable balance, is less susceptible to RFI/EMI in noisy environments
- Reduce installation time and costs: 10GXW is the smallest and lightest horizontal Category 6A cable available
- Unparalleled performance: Full 100m channel length under 100W PoE load without derating up to 60°C using 10GXS cables
- Designed to Last: Higher pulling tensions and tighter bend radii offered by Bonded-Pair Cables
Specifications
Product Overview
Suitable Applications |
Industrial Ethernet cables are used for interconnecting Industrial Ethernet Switches, programmable logic controller and transmitting industrial protocol data signals. These cables are suitable for transmitting 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, 500MHz Category 6A. These are highly durable & ruggedized cables for both indoor and outdoor use meeting IEC 60332-3-22 and IEC 60754-1 & 2 |
---|
Construction Details
Conductor
Element | Size | Stranding | Material | No. of Pairs |
---|---|---|---|---|
Conductor(s) | 23 AWG | Solid | BC – Bare Copper | 4 |
Insulation
Element | Material | Nom. Insulation Diameter | Color Code |
---|---|---|---|
Conductor(s) | PO – Polyolefin (Foam) | 1.4 mm (0.055 in) | Blue & White, Orange & White, Green & White, Brown & White |
Inner Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Inner Jacket
Material | Nom. Diameter |
---|---|
LSZH – Low Smoke Zero Halogen (SHF1) | 8 mm (0.31 in) |
Outer Shield
Shield Type | Material | Coverage |
---|---|---|
Braid | Tinned Copper (TC) | 65% |
Armor
Armor Type & Material | Armor Material Diameter |
---|---|
SWB – Steel Wire Braid Armor | 0.2 mm (0.0079 in) |
Outer Jacket
Material | Nom. Diameter |
---|---|
LSZH – Low Smoke Zero Halogen (SHF1) | 10.6 mm (0.417 in) |
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|---|
95 Ohm/km (29 Ohm/1000ft) | 160 pF/100m |
Table Notes |
Mutual capacitance : |
---|
Delay
Max. Delay Skew | Nom. Velocity of Prop. |
---|---|
45 ns/100m | 78% |
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. PSANEXT [dB] | Min. PSAACRF [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2.1 dB/100m | 75.3 | 72.3 | 68 | 65 | 20 | 67 | 67 | 40 | 35 |
4 | 3.8 dB/100m | 66.3 | 63.3 | 56 | 53 | 23 | 67 | 66.2 | 34 | 23 |
10 | 5.9 dB/100m | 60.3 | 57.3 | 48 | 45 | 25 | 67 | 58.2 | 30 | 15 |
16 | 7.5 dB/100m |
57.2