Features & Benefits
- Built to Last: Enjoy peace of mind in the field with a reliable, ruggedized solution that lasts over time
- Consistent Performance: Designed for high-volume data transfer after installation to maintain maximum uptime
- Extensive Product Portfolio: Choose the best cable for your application with a wide variety of options to meet your needs
Specifications
Product Overview
Suitable Applications |
extreme temp, exposure to oil and gasoline, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. |
---|---|
Patent |
This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | No. of Pairs |
---|---|---|---|---|
Pair(s) | 24 | Solid | BC – Bare Copper | 4 |
Conductor Count |
8 |
---|---|
Total Number of Pairs |
4 |
Insulation
Element | Material | Nominal Diameter | Nominal Wall Thickness |
---|---|---|---|
Pair(s) | FEP – Fluorinated Ethylene Propylene | 0.044 in | 0.011 in |
Bonded-Pair |
Yes |
---|
Color Chart
Number | Color |
---|---|
1 | Blue & White/Blue |
2 | Orange & White/Orange |
3 | Green & White/Green |
4 | Brown & White/Brown |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
---|---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC – Tinned Copper | 24 |
Outer Jacket
Material | Nominal Diameter |
---|---|
FEP – Fluorinated Ethylene Propylene | 0.231 in |
Electrical Characteristics
Conductor DCR
Max. Conductor DCR | Max. DCR Unbalance |
---|---|
29.7 Ohm/1000ft | 3.0 % |
Capacitance
Max. Capacitance Unbalance | Nom.Mutual Capacitance |
---|---|
66 pF/ft | 15 pF/ft |
Delay
Max. Delay | Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
---|---|---|
510 ns/100m | 25 ns/100m | 72% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) |
---|---|---|---|---|---|---|---|---|---|
1 MHz | 2 dB/100m | 65.3 dB | 65.3 dB | 63.3 dB | 63.3 dB | 63.8 dB | 60.8 dB | 20 dB | 100 ± 12 Ohm |
4 MHz | 4 dB/100m | 56.3 dB | 56.3 dB | 52.3 dB | 52.3 dB | 51.7 dB | 48.7 dB | 23.6 dB | 100 ± 12 Ohm |
8 MHz
Resources |
Belden Industrial Ethernet Cable Brochure
Belden Industrial Ethernet Cable Selector