Features & Benefits
- Built to Last: Enjoy peace of mind in the field with a reliable, ruggedized solution that lasts over time
- Consistent Performance: Designed for high-volume data transfer after installation to maintain maximum uptime
- Extensive Product Portfolio: Choose the best cable for your application with a wide variety of options to meet your needs
Specifications
Product Overview
Suitable Applications |
RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, …); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. |
---|
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 4 | 24 AWG | 7×32 | TC – Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Pair(s) | PE – Polyethylene | 0.022 in (0.56 mm) | 0.068 in (1.7 mm) | White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe, White/Green Stripe & Green/White Stripe, White/Brown Stripe & Brown/White Stripe |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7×32) TC |
Braid | Tinned Copper (TC) | 90% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.035 in (0.89 mm) | 0.390 in (9.91 mm) |
Table Notes |
Jacket OD +/- 0.030 |
---|---|
Overall Cable Diameter (Nominal) |
0.390 in (9.91 mm) |
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|---|
Pair(s) | 24 Ohm/1000ft | 12.8 pF/ft (42.0 pF/m) | 23 pF/ft | 120 Ohm | 66% | 1.54 Amps per Conductor at 25ºC |
Nom. Outer Shield DCR |
2.1 Ohm/1000ft (6.9 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|---|---|
Pair(s) | 1 | 0.6 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CM), 30 V (UL AWM 2919) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
80°C | -30°C to +80°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
4 in (100 mm) | 4 in (100 mm) |
Max. Pull Tension |
110 lbs (50 kg) |
---|---|
Bulk Cable Weight |
71 lbs/1000ft |
Standards and Compliance
Environmental Suitability |
Indoor |
||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flammability / Reaction to Fire |
UL 1685 UL Loading, IEC 60332-1-2 |
||||||||||||||||||||||||
CPR Compliance |
CPR Euroclass: Fca Part Numbers
|
Belden Industrial Ethernet Cable Brochure
Belden Industrial Ethernet Cable Selector