10GXE02 – 10GX Category 6A Enhanced Cable, 4 Pair, S/FTP, LSZH Indoor CPR Eca


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Horizontal and building backbone cable; Support current and future Category 6A and 6 applications, such as: 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM

Construction Details

Conductor
Element Size Stranding Material No. of Pairs No. of Elements
Individual Shielded Pair 23 AWG Solid BC – Bare Copper 4 8
Insulation
Element Material Nom. Insulation Diameter Color Code
Individual Shielded Pair PE – Polyethylene (Foam) 1.32 mm (0.0520 in) White & Blue, White & Orange, White & Green, White & Brown
Cable Core
Description
4 pairs twisted together
Inner Shield
Element Shield Type Material Coverage
Individual Shielded Pair Tape Bi-Laminate (Alum+Poly) 100%
Table Notes: Aluminum facing outside
Outer Shield
Shield Type Material Coverage
Braid Tinned Copper (TC) 30%
Outer Jacket
Material Nom. Diameter Ripcord
LSZH – Low Smoke Zero Halogen (Flame Retardant) 7.0 mm (0.28 in) Yes
Overall Cable Diameter (Nominal): 7.0 mm (0.28 in)

Electrical Characteristics

Electricals
Max. Conductor DCR Max. Mutual Capacitance Max. Capacitance Unbalance Nom. Characteristic Impedance
95 Ohm/km 56 pF/m (17 pF/ft) 160 pF/100m 100 Ohm
Delay
Max. Delay Skew Nom. Velocity of Prop.
45 ns/100m 77%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. PSANEXT [dB] Min. PSAACRF [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 2.1 dB/100m 75.3 72.3 73.2 70.2 68 65 20 67 67 40 35
4 3.8 dB/100m 66.3 63.3 62.5 59.5 56 53 23 67 66.2 34 23
10 5.9 dB/100m 60.3 57.3 54.4 51.4 48 45 25 67 58.2 30 15
16 7.5 dB/100m 57.2 54.2 49.8 46.8 43.9 40.9 25 67 54.1 28 10.9
31.2 10.5 dB/100m 52.9 49.9 42.4 39.4 38.1 35.1 23.6 67 48.3 25.1 5.1
62.5 15 dB/100m 48.4 45.4 33.4 30.4 32.1 29.1 21.5 65.6 42.3 22
100 19.1 dB/100m 45.3 42.3 26.2 23.2 28 25 20.1 62.5 38.2 20
125 21.5 dB/100m 43.8 40.8 22.3 19.3 26.1 23.1 19.4 61 36.3 19
200 27.6 dB/100m 40.8 37.8 13.2 10.2 22 19 18 58 32.2 17
250 31.1 dB/100m 39.3 36.3 8.3 5.3 20 17 17.3 56.5 30.2 16
300 34.3 dB/100m 38.1 35.1 3.9 0.9 18.5 15.5 17.3 55.3 28.7
500 45.3 dB/100m 34.8 31.8 -10.4 -13.4 14 11 17.3 52 24.2
625 51.2 dB/100m 33.4 30.4 -17.8 -20.8 12.1 9.1 17.3 50.6 22.3
Table Notes: Limits below 4 MHz and at 625 MHz are for information only.
Reference standard: IEC 61156-5
Transfer Impedance
Frequency Max. Transfer Impedance
1 Mhz Max. 50 mOhm/m
10 Mhz Max. 100 mOhm/m
30 Mhz Max. 200 mOhm/m
100 Mhz Max. 1000 mOhm/m
Transfer Impedance Class: Grade 2
Screening Class: Type Ib
Table Notes: Coupling Attenuation
Voltage
Voltage Rating
72 V DC

Mechanical Characteristics

Temperature
Operating Installation
-30°C to +60°C 0°C To +50°C
Bend Radius
Stationary Min. Installation Min.
29 mm (1.1 in) 58 mm
Max. Pull Tension: 85 N (19 lbf)
Bulk Cable Weight: 52 kg/km

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Eca
Flammability / Reaction to Fire: IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca; CPR UKCA Class: Eca
IEEE Compliance: PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data Category: Category 6A
TIA/EIA Compliance: ANSI/TIA 568.2-D
ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61034-2 – Smoke Density Min Transmittance = 60%
CENELEC Compliance: EN 50173-1, Segregation class according EN50174-2 = d
European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
European Directive Compliance: EU CE Mark
UK Regulation Compliance: UKCA Mark

Product Notes

Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system.

History

Update and Revision: Revision Number: 0.312 Revision Date: 01-17-2024

Part Numbers

Variants
Item # Color Putup Type Length EAN
10GXE02.10500 Black Reel 500 m 8719605222268
10GXE02 006305M Blue Reel 305 m
10GXE02.06500 Blue Reel 500 m 8719605000385
10GXE02 006500M Blue Reel 500 m
10GXE02.08100 Gray Reel 100 m 8719605000408
10GXE02.K8100 Gray Reel 100 m 8719605147868
10GXE02 008305M Gray Reel 305 m
10GXE02.08500 Gray Reel 500 m 8719605000415
10GXE02 008500M Gray Reel 500 m
10GXE02.05500 Green Reel 500 m 8719605222077
10GXE02.03500 Orange Reel 500 m 8719605130068
10GXE02.07305 Purple Reel 305 m
10GXE02 007305M Purple Reel 305 m
10GXE02.07500 Purple Reel 500 m 8719605000392
10GXE02 007500M Purple Reel 500 m
10GXE02.02500 Red Reel 500 m 8719605195012
10GXE02 009305M White Reel 305 m
10GXE02.09500 White Reel 500 m 8719605222251
10GXE02 009500M White Reel 500 m
10GXE02 004305M Yellow Reel 305 m
10GXE02.04500 Yellow Reel 500 m 8719605195029
10GXE02 004500M Yellow Reel 500 m