Product Overview
Suitable Applications: | 4-pair 24AWG halogen-free multi-core cable; For analogue audio |
Physical Characteristics (Overall)
AWG | Stranding | Material | Construction n x D |
---|---|---|---|
24 | 7×32 | TC – Tinned Copper | 7×0.20 mm |
Conductor Count: | 8 |
Total Number of Pairs: | 4 |
Type | Material | Nominal Diameter | Diameter +/- Tolerance |
---|---|---|---|
Insulation | PE – Polyethylene | 1.02 mm | 0.05 mm |
Number | Color |
---|---|
Pair 1 t/m 4 | Red & Black |
Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D | Drainwire Position |
---|---|---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | Stranded tinned copper | 24 | 7×0.20 mm | Under shielding foil |
Table Notes: | Aluminum inside |
Material | Nominal Diameter |
---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 2.86 mm |
Table Notes: | Jacket single element, elements are numbered 1 – 4 |
Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | TC – Tinned Copper | 7xAWG26 | 7×0.40 mm |
Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
---|---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 8.90 mm | 0.40 mm | 1.00 mm |
Construction and Dimensions
Description |
---|
1 center filler + 4 pairs |
Min Elongation at Breakof Jacket: | 125 % |
Min Tensile Strength of Jacket: | 9 MPa |
Electrical Characteristics
Max. Conductor DCR | Nominal Inner Shield DCR |
---|---|
88.5 Ohm/km | 52 Ohm/km |
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
---|---|
92 pF/m | 180 pF/m |
Nominal Inductance |
---|
0.75 µH/m |
Temperature Range
Other Temp Range: | -30 to +70 °C |
Mechanical Characteristics
Max. Pull Tension: | 246 N |
Min. Bend Radius During Installation: | 89 mm |
Min. Bend Radius During Operation: | 133.5 mm |
Standards
CPR Euroclass: | Dca-s1,d1,a1 |
CENELEC Compliance: | EN 50290-2-20 |
Applicable Environmental and Other Programs
Environmental Space: | Indoor – Euroclass Dca |
EU Directive 2011/65/EU (RoHS 2): | Yes |
Flammability, LS0H, Toxicity Testing
IEC Flammability: | IEC 60332-1-2, IEC 60332-3-24 |
IEC 60754-1 – Halogen Amount: | Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
Related Part Numbers
Item # | Color | Put-Up Type | Length | EAN |
---|---|---|---|---|
1510ECH.00500 | Black | Reel | 500 m | 8719605001702 |
History
Update and Revision: | Revision Number: 0.190 Revision Date: 12-22-2023 |