1875GB – CAT6+ Patch Bonded-Pair, 4pr, UTP, PVC Jkt, CMR


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Premise Patch Cable Designed for Attenuation Stability in High Humidity Environments, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, Noisy Environments, For T568-B Wiring

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
24 7×32 TC – Tinned Copper 4
Conductor Count: 8
Total Number of Pairs: 4
Insulation
Material
PO – Polyolefin
Bonded-Pair: Yes
Color Chart
Number Color
1 White/Brown Stripe & Brown
2 White/Blue Stripe & Blue
3 White/Green Stripe & Green
4 White/Orange Stripe & Orange
Outer Jacket
Material Nominal Diameter Ripcord
PVC – Polyvinyl Chloride 0.365 x 0.165 in No

Electrical Characteristics

Conductor DCR
Max. Conductor DCR Max. DCR Unbalance
90 Ohm/km 3 %
Capacitance
Max. Capacitance Unbalance Nom.Mutual Capacitance
49.2 pF/100m 15 pF/ft
Delay
Frequency [MHz] Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
100 MHz 537.6 ns/100m 25 ns/100m 70%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance
1 MHz 2.0 dB/100m 74.3 dB 72.3 dB 70.3 dB 70.3 dB 67.8 dB 64.8 dB 20.0 dB 100 ± 12 Ohm 100 ± 15 Ohm
4 MHz 4.1 dB/100m 65.3 dB 63.3 dB 59.2 dB 59.2 dB 55.7 dB 52.8 dB 23.0 dB 100 ± 12 Ohm 100 ± 15 Ohm
8 MHz 5.8 dB/100m 60.3 dB 58.8 dB 53.0 dB 53.0 dB 49.7 dB 46.7 dB 24.5 dB 100 ± 12 Ohm 100 ± 15 Ohm
10 MHz 6.5 dB/100m 59.3 dB 57.3 dB 51.0 dB 51.0 dB 47.8 dB 44.8 dB 25.0 dB 100 ± 12 Ohm 100 ± 15 Ohm
16 MHz 8.2 dB/100m 56.3 dB 54.3 dB 46.0 dB 46.0 dB 43.7 dB 40.7 dB 25.0 dB 100 ± 12 Ohm 100 ± 8 Ohm
20 MHz 9.3 dB/100m 54.8 dB 52.8 dB 43.5 dB 43.5 dB 41.7 dB 38.7 dB 25.0 dB 100 ± 12 Ohm 100 ± 8 Ohm
25 MHz 10.4 dB/100m 53.4 dB 51.4 dB 41.0 dB 42.0 dB 39.8 dB 36.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 8 Ohm
31.25 MHz 11.7 dB/100m 51.9 dB 49.9 dB 38.2 dB 38.2 dB 37.9 dB 34.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 8 Ohm
62.5 MHz 17.0 dB/100m 47.4 dB 45.4 dB 28.4 dB 28.4 dB 31.8 dB 28.9 dB 21.5 dB 100 ± 15 Ohm 100 ± 8 Ohm
100 MHz 22.0 dB/100m 44.3 dB 42.3 dB 25.0 dB 25.0 dB 27.8 dB 24.8 dB 21.0 dB 100 ± 15 Ohm 100 ± 8 Ohm
155 MHz 30.2 dB/100m 41.5 dB 39.5 dB 14.0 dB 14.0 dB 23.9 dB 20.9 dB 21.0 dB 100 ± 15 Ohm 100 ± 8 Ohm
200 MHz 34.8 dB/100m 39.8 dB 37.8 dB 10.0 dB 10.0 dB 21.7 dB 18.8 dB 21.0 dB 100 ± 15 Ohm 100 ± 8 Ohm
250 MHz 39.6 dB/100m 38.3 dB 36.3 dB 3.0 dB 3.0 dB 19.8 dB 16.8 dB 18.0 dB 100 ± 20 Ohm 100 ± 8 Ohm
300 MHz 46.7 dB/100m 37.2 dB 35.2 dB 18.2 dB 15.2 dB 18.0 dB 100 ± 20 Ohm 100 ± 8 Ohm
310 MHz 47.6 dB/100m 36.9 dB 34.9 dB 17.9 dB 14.9 dB 18.0 dB 100 ± 20 Ohm 100 ± 8 Ohm
350 MHz 51.1 dB/100m 36.2 dB 34.2 dB 16.9 dB 13.9 dB 17.0 dB 100 ± 22 Ohm 100 ± 8 Ohm
400 MHz 55.3 dB/100m 35.3 dB 33.3 dB 15.7 dB 12.7 dB 14.0 dB 100 ± 32 Ohm 100 ± 8 Ohm
500 MHz 63.3 dB/100m 33.8 dB 31.8 dB 13.8 dB 10.8 dB 14.0 dB 100 ± 32 Ohm 100 ± 8 Ohm
Voltage
UL Voltage Rating
300 V RMS

Temperature Range

Installation Temperature Range: 0°C To +50°C
UL Temp Rating: 75°C
Storage Temperature Range: -20°C To +75°C
Operating Temperature Range: -20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight: 28 lbs/1000ft
Max. Pull Tension: 40 lbs
Min. Bend Radius During Installation: 3.75 in
Min. Bend Radius/Minor Axis: 0.5 in

Standards

NEC/(UL) Compliance: CMR
CEC/C(UL) Compliance: CMR
ISO/IEC Compliance: 11801 ed 2.2 (2011) Class E Patch
CPR Euroclass: Eca
Data Category: Category 6
ANSI Compliance: S-116-732-2013 Category 6 Patch, ANSI/NEMA WC-66 Category 6 Patch
TIA/EIA Compliance: ANSI/TIA-568-C.2 Category 6 Patch
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Third Party Performance Verification: Category 6 Patch

Applicable Environmental and Other Programs

Environmental Space: Riser
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: Yes
EU CE Mark: Yes
EU REACH SVHC Compliance (yyyy-mm-dd): 2017-07-10
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Aerial: No
Suitability – Burial: No
Suitability – Hazardous Locations: No
Suitability – Indoor: Yes
Suitability – Non-Halogenated: No
Suitability – Oil Resistance: No
Suitability – Outdoor: No
Suitability – Sunlight Resistance: No

Flammability, LS0H, Toxicity Testing

CSA/C(UL) Flammability: FT4
UL Flammability: UL 1666 Riser
IEC Flammability: IEC 60332-1-2
UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): No

Related Part Numbers

Variants
Item # Color Put-Up Type Length UPC
1875GB 0101000 Black Reel 1,000 ft 612825125754
1875GB 0061000 Blue Reel 1,000 ft 612825125723
1875GB 006A1000 Blue Reel-in-Box 1,000 ft 612825125716
1875GB F2V1000 Gray Reel 1,000 ft 612825125662
1875GB F6H1000 Gray Reel 1,000 ft 612825125679
1875GB 0051000 Green Reel 1,000 ft 612825125709
1875GB 005A1000 Green Reel-in-Box 1,000 ft 612825125693
1875GB 007A1000 Purple Reel-in-Box 1,000 ft 612825125730
1875GB 0091000 White Reel 1,000 ft 612825125747
1875GB 0041000 Yellow Reel 1,000 ft 612825125686
Footnote: C – CRATE REEL PUT-UP.

Product Notes

Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 350 MHz are information only. Print Includes Descending Footage Markings. Conductor strands are bonded together.

History

Update and Revision: Revision Number: 0.511 Revision Date: 12-12-2023