Product Overview
Suitable Applications: | Intercom/PA Systems, Sound/Audio Systems, Control Systems |
Physical Characteristics (Overall)
AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
---|---|---|---|---|
18 | 7×26 | BC – Bare Copper | 1.22 mm | 4 |
Conductor Count: | 8 |
Total Number of Pairs: | 4 |
Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
---|---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 1.72 mm | 0.05 mm | 0.26 mm |
Number | Color |
---|---|
Pair 1 | Black & Red |
Pair 2 | Black & White |
Pair 3 | Black & Green |
Pair 4 | Black & Blue |
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
---|---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC – Tinned Copper | AWG24/7 |
Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
---|---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 9.5 mm | 1.2 mm | Yes |
Table Notes: | Ripcord provided under sheath |
Construction and Dimensions
Description |
---|
4 pairs twisted |
Electrical Characteristics
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|---|
21.3 Ohm/km | 21.9 Ohm/km |
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|---|
125 pF/m | 224 pF/m |
Max. Recommended Current [A] |
---|
3.5 Amps per Conductor |
Voltage Rating [V] |
---|
300 V |
Temperature Range
Installation Temperature Range: | -20°C To +70°C |
Storage Temperature Range: | -30°C to +70°C |
Operating Temperature Range: | -20°C To +70°C |
Mechanical Characteristics
Max. Pull Tension: | 320 N |
Min. Bend Radius During Installation: | 95 mm |
Min Setting Radius: | 47 mm |
Standards
CPR Euroclass: | Cca-s1,d1,a1 |
Applicable Environmental and Other Programs
Environmental Space: | Indoor – Euroclass Cca |
Flammability, LS0H, Toxicity Testing
IEC Flammability: | IEC 60332-1-2 |
IEC 60754-1 – Halogen Amount: | Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
History
Update and Revision: | Revision Number: 0.12 Revision Date: 12-22-2023 |