Product Overview
Suitable Applications: | Monitor/Detection, Control Circuits, Initiating Circuits, Notification Circuits |
Construction Details
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 3 | 18 AWG | 7×26 | TC – Tinned Copper |
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | PVC – Polyvinyl Chloride | 0.009 in (0.23 mm) | 0.064 in (1.6 mm) | Black, Red, White |
Material |
---|
No Shield |
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|---|---|---|
PVC – Polyvinyl Chloride | 0.015 in (0.38 mm) | 0.168 in | Yes |
Overall Cable Diameter (Nominal): | 0.168 in |
Electrical Characteristics
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Max. Current |
---|---|---|
6.4 Ohm/1000ft | 34 pF/ft (110 pF/m) | 5 Amps per Conductor at 25ºC |
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
UL Temperature | Operating |
---|---|
75°C | -20°C To +75°C |
Stationary Min. | Installation Min. |
---|---|
1.68 in (42.7 mm) | 1.68 in |
Max. Pull Tension: | 67 lbs (30 kg) |
Bulk Cable Weight: | 24 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor – Plenum, Indoor |
Flammability / Reaction to Fire: | NFPA 262 (UL 910), FT6 |
NEC / UL Compliance: | Article 800, CMP |
CEC / C(UL) Compliance: | CMP |
European Directive Compliance: | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Non-Plenum Number: | 5301UH |
History
Update and Revision: | Revision Number: 0.51 Revision Date: 12-20-2022 |
Part Numbers
Item # | Color | Putup Type | Length | UPC |
---|---|---|---|---|
6301UH 8771000 | Natural | Reel | 1,000 ft | 612825175230 |
6301UH 877U1000 | Natural | UnReel | 1,000 ft | 612825175261 |