Product Overview
Suitable Applications: | Instrumentation and computer cable; For EIA RS-232 data transmission applications |
Physical Characteristics (Overall)
AWG | Stranding | Material | No. of Pairs |
---|---|---|---|
24 | 7×32 | TC – Tinned Copper | 6 |
Conductor Count: | 12 |
Material | Nominal Diameter | Diameter +/- Tolerance |
---|---|---|
PE – Polyethylene | 1.12 mm | 0.05 mm |
Number | Color |
---|---|
Pair 1 (central) | Black & Red |
Pair 2 | Black & White |
Pair 3 | Black & Green |
Pair 4 | Black & Blue |
Pair 5 | Black & Yellow |
Pair 6 | Black & Brown |
Type | Material | Material Trade Name | Thickness of Foil | Drainwire Material | Drainwire AWG |
---|---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 9 / 23 µm | TC – Tinned Copper | AWG24/7 |
Material | Nominal Diameter | Nominal Wall Thickness |
---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 7.5 mm | 0.9 mm |
Construction and Dimensions
Description |
---|
6 pairs twisted to cable core |
Electrical Characteristics
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|---|
78.7 Ohm/km | 52.5 Ohm/km |
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|---|
98.4 pF/m | 164 pF/m |
Frequency [MHz] | Nominal Characteristic Impedance |
---|---|
N/A | 75 Ohm |
Element | Max. Recommended Current [A] |
---|---|
Conductor(s) | 1.5 Amps per Conductor |
Voltage Rating [V] |
---|
300 V |
Temperature Range
Installation Temperature Range: | -15°C To +80°C |
Storage Temperature Range: | -45°C To +80°C |
Operating Temp Range (Flexible Install): | -15°C To +80°C |
Operating Temp Range (Fixed Install): | -45°C To +80°C |
Mechanical Characteristics
Oil Resistance: | IEC 60811-404 |
Max. Pull Tension: | 300 N |
Min. Bend Radius During Installation: | 75 mm |
Standards
CPR Euroclass: | Dca-s2,d1,a1 |
CENELEC Compliance: | EN 50290-2-20 |
Applicable Environmental and Other Programs
Environmental Space: | Indoor – Euroclass Dca |
Suitability
Suitability – Sunlight Resistance: | Yes |
Flammability, LS0H, Toxicity Testing
IEC Flammability: | IEC 60332-1-2, IEC 60332-3-24 |
IEC 60754-1 – Halogen Amount: | Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
Related Part Numbers
Item # | Color | Put-Up Type | Length | EAN |
---|---|---|---|---|
9506NH.00152 | Chrome | Reel | 152 m | 8719605021427 |
9506NH.00305 | Chrome | Reel | 305 m | 8719605021434 |
9506NH.00500 | Chrome | Reel | 500 m | 8719605021441 |
9506NH.001000 | Chrome | Reel | 1,000 m | 8719605021410 |
History