Product Overview
Suitable Applications: |
RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, …); Low Voltage Digital Control (24v,
); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Pairs |
24 |
7×32 |
TC – Tinned Copper |
2 |
Material |
Nominal Diameter |
Diameter +/- Tolerance |
PE – Polyethylene |
1.73 mm |
0.05 mm |
Number |
Color |
Pair 1 |
White/Blue & Blue/White |
Pair 2 |
White/Orange & Orange/White |
Type |
Layer |
Material |
Material Trade Name |
Coverage [%] |
Thickness of Foil |
Drainwire AWG |
Tape |
1 |
Bi-Laminate (Alum+Poly) |
Beldfoil® (Z-Fold®) |
100% |
9 / 23 µm |
AWG24/7 |
Braid |
2 |
Tinned Copper (TC) |
|
90% |
|
|
Material |
Color |
Nominal Diameter |
Nominal Wall Thickness |
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
Chrome (RAL 7037) |
8.40 mm |
1.0 mm |
Construction and Dimensions
Lay Direction |
Twists |
Left Hand |
12 twist/ft |
Description |
2 pairs and 2 fillers twisted to cable core |
Electrical Characteristics
Nominal Conductor DCR |
Nominal Outer Shield DCR |
78.7 Ohm/km |
7.2 Ohm/1000ft |
Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
42 pF/m |
75.5 pF/m |
Frequency [MHz] |
Nominal Characteristic Impedance |
1 |
120 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] |
Nom. Insertion Loss |
1 MHz |
1.97 dB/100m |
Max. Delay Skew |
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
66 ns/100m |
5.2 ns/m |
66% |
Max. Recommended Current [A] |
2.1 Amps per Conductor |
Temperature Range
Installation Temperature Range: |
-15°C To +80°C |
Storage Temperature Range: |
-45°C To +80°C |
Operating Temperature Range: |
-20°C To +80°C |
Operating Temp Range (Flexible Install): |
-15°C To +80°C |
Operating Temp Range (Fixed Install): |
-45°C To +80°C |
Mechanical Characteristics
Oil Resistance: |
IEC 60811-404 |
Min. Bend Radius During Installation: |
88 mm |
Standards
CPR Euroclass: |
Cca-s1a,d1,a1 |
CENELEC Compliance: |
EN 50290-2-20 |
Other Specification: |
DMX-512 |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor – Euroclass Cca |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Indoor: |
Yes |
Suitability – Non-Halogenated: |
Yes |
Suitability – Oil Resistance: |
Yes |
Suitability – Sunlight Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
IEC Flammability: |
IEC 60332-1-2 |
IEC 60754-1 – Halogen Amount: |
Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: |
2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: |
4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: |
80% |
Related Part Numbers
Item # |
Color |
Put-Up Type |
Length |
EAN |
9842LW.00500 |
Chrome |
Reel |
500 m |
8719605193681 |
History
Update and Revision: |