Discontinued Products
Showing 9817–9840 of 10717 results
-
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1487CB60) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
- Typical Straight Section
- Flat Sealing Plate
- Angle Sealing Plate
- Barrier Kit
- Swivel Nipple
- Flexible Fitting
- Adjustable Fitting
- Cross Fitting
- Cut-Off Fitting (Lay-In)
- Cut-Off Fitting (Non Lay-In)
- Nipple
- 45 degree Elbow Top Opening
- 45 degree Elbow Inside Opening
- 45 degree Elbow Outside Opening
- 90 degree Elbow Top Opening
- 90 degree Elbow Inside Opening
- 90 degree Elbow Outside Opening
- Tee Fitting Top Opening
- Tee Fitting Outside and Top Opening
- Reducers
- Box Connector
- 12″ Transposition Sections Clockwise & Counter-Clockwise
- Drop Hanger
- Bracket Hanger
- Cover Plate
- Junction Box
SKU: 1487CB60 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485BS9) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
- Typical Straight Section
- Flat Sealing Plate
- Angle Sealing Plate
- Barrier Kit
- Swivel Nipple
- Flexible Fitting
- Adjustable Fitting
- Cross Fitting
- Cut-Off Fitting (Lay-In)
- Cut-Off Fitting (Non Lay-In)
- Nipple
- 45 degree Elbow Top Opening
- 45 degree Elbow Inside Opening
- 45 degree Elbow Outside Opening
- 90 degree Elbow Top Opening
- 90 degree Elbow Inside Opening
- 90 degree Elbow Outside Opening
- Tee Fitting Top Opening
- Tee Fitting Outside and Top Opening
- Reducers
- Box Connector
- 12″ Transposition Sections Clockwise & Counter-Clockwise
- Drop Hanger
- Bracket Hanger
- Cover Plate
- Junction Box
SKU: 1485BS9 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485BSM) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
- Typical Straight Section
- Flat Sealing Plate
- Angle Sealing Plate
- Barrier Kit
- Swivel Nipple
- Flexible Fitting
- Adjustable Fitting
- Cross Fitting
- Cut-Off Fitting (Lay-In)
- Cut-Off Fitting (Non Lay-In)
- Nipple
- 45 degree Elbow Top Opening
- 45 degree Elbow Inside Opening
- 45 degree Elbow Outside Opening
- 90 degree Elbow Top Opening
- 90 degree Elbow Inside Opening
- 90 degree Elbow Outside Opening
- Tee Fitting Top Opening
- Tee Fitting Outside and Top Opening
- Reducers
- Box Connector
- 12″ Transposition Sections Clockwise & Counter-Clockwise
- Drop Hanger
- Bracket Hanger
- Cover Plate
- Junction Box
SKU: 1485BSM -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485BH) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
- Typical Straight Section
- Flat Sealing Plate
- Angle Sealing Plate
- Barrier Kit
- Swivel Nipple
- Flexible Fitting
- Adjustable Fitting
- Cross Fitting
- Cut-Off Fitting (Lay-In)
- Cut-Off Fitting (Non Lay-In)
- Nipple
- 45 degree Elbow Top Opening
- 45 degree Elbow Inside Opening
- 45 degree Elbow Outside Opening
- 90 degree Elbow Top Opening
- 90 degree Elbow Inside Opening
- 90 degree Elbow Outside Opening
- Tee Fitting Top Opening
- Tee Fitting Outside and Top Opening
- Reducers
- Box Connector
- 12″ Transposition Sections Clockwise & Counter-Clockwise
- Drop Hanger
- Bracket Hanger
- Cover Plate
- Junction Box
SKU: 1485BH -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485BL2) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
- Typical Straight Section
- Flat Sealing Plate
- Angle Sealing Plate
- Barrier Kit
- Swivel Nipple
- Flexible Fitting
- Adjustable Fitting
- Cross Fitting
- Cut-Off Fitting (Lay-In)
- Cut-Off Fitting (Non Lay-In)
- Nipple
- 45 degree Elbow Top Opening
- 45 degree Elbow Inside Opening
- 45 degree Elbow Outside Opening
- 90 degree Elbow Top Opening
- 90 degree Elbow Inside Opening
- 90 degree Elbow Outside Opening
- Tee Fitting Top Opening
- Tee Fitting Outside and Top Opening
- Reducers
- Box Connector
- 12″ Transposition Sections Clockwise & Counter-Clockwise
- Drop Hanger
- Bracket Hanger
- Cover Plate
- Junction Box
SKU: 1485BL2 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485BL1) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
- Typical Straight Section
- Flat Sealing Plate
- Angle Sealing Plate
- Barrier Kit
- Swivel Nipple
- Flexible Fitting
- Adjustable Fitting
- Cross Fitting
- Cut-Off Fitting (Lay-In)
- Cut-Off Fitting (Non Lay-In)
- Nipple
- 45 degree Elbow Top Opening
- 45 degree Elbow Inside Opening
- 45 degree Elbow Outside Opening
- 90 degree Elbow Top Opening
- 90 degree Elbow Inside Opening
- 90 degree Elbow Outside Opening
- Tee Fitting Top Opening
- Tee Fitting Outside and Top Opening
- Reducers
- Box Connector
- 12″ Transposition Sections Clockwise & Counter-Clockwise
- Drop Hanger
- Bracket Hanger
- Cover Plate
- Junction Box
SKU: 1485BL1 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485BK) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
- Typical Straight Section
- Flat Sealing Plate
- Angle Sealing Plate
- Barrier Kit
- Swivel Nipple
- Flexible Fitting
- Adjustable Fitting
- Cross Fitting
- Cut-Off Fitting (Lay-In)
- Cut-Off Fitting (Non Lay-In)
- Nipple
- 45 degree Elbow Top Opening
- 45 degree Elbow Inside Opening
- 45 degree Elbow Outside Opening
- 90 degree Elbow Top Opening
- 90 degree Elbow Inside Opening
- 90 degree Elbow Outside Opening
- Tee Fitting Top Opening
- Tee Fitting Outside and Top Opening
- Reducers
- Box Connector
- 12″ Transposition Sections Clockwise & Counter-Clockwise
- Drop Hanger
- Bracket Hanger
- Cover Plate
- Junction Box
SKU: 1485BK -
Discontinued Products
Eclipse Command System – NEMA 12 ECP Series – (ECPP2024) (DISCONTINUED)
Application
- Designed to enclose electronic controls, instruments and components in indoor environments where dirt, dust, oil and water may be present.
- Ideal for use with suspension systems.
- Multiple mounting provisions and full front mounting space provide for ideal operator interface.
- Smooth flush surfaces and attractive finishes compliment high tech equipment.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12 and 13
- IEC 60529, IP54
Construction
- Formed from 16 gauge steel.
- Smooth, continuously welded seams ground smooth.
- Door stiffeners are designed to also permit additional mounting options.
- Formed lip on enclosure to exclude flowing liquids and contaminants.
- Reversible rear door is secured with slotted quarter turn fasteners.
- Door frames have zinc die-cast corners with extrusion pressed aluminum profiles.
- Door front panels are 3mm aluminum.
- Oil resistant gaskets are permanently secured.
- Bonding stud provided on door and grounding stud installed in enclosure.
- Quarter turn latches formed from mild steel.
- Formed steel hinge with stainless steel hinge pins.
- Fastening is recommended with optional Tara Plus or 50/80 suspension systems.
- Optional red handle easily mounts horizontally to bottom of enclosure front frame. Order separately.
- Heavy duty re-inforcing plate included.
Finish
- Finished in RAL 7040 gray powder coating.
- Door panel is natural aluminum.
Accessories
- Optional Inner Panel
- Optional Handle
- Window Kits
- Tara Plus Suspension System
- Heavy Duty 50/80 mm Suspension Systems
- Climate Control
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Optional Panel Part No. H W D Part No. ECP12126 12.00 12.00 6.00 ECPP1212 ECP12168 12.00 16.00 8.00 ECPP1216 ECP161610 16.00 16.00 10.00 ECPP1616 ECP162010 16.00 20.00 10.00 ECPP1620 ECP20246 20.00 24.00 6.00 ECPP2024 ECP202412 20.00 24.00 12.00 ECPP2024 SKU: ECPP2024 -
Discontinued Products
Eclipse Command System – NEMA 12 ECP Series – (ECPP1620) (DISCONTINUED)
Application
- Designed to enclose electronic controls, instruments and components in indoor environments where dirt, dust, oil and water may be present.
- Ideal for use with suspension systems.
- Multiple mounting provisions and full front mounting space provide for ideal operator interface.
- Smooth flush surfaces and attractive finishes compliment high tech equipment.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12 and 13
- IEC 60529, IP54
Construction
- Formed from 16 gauge steel.
- Smooth, continuously welded seams ground smooth.
- Door stiffeners are designed to also permit additional mounting options.
- Formed lip on enclosure to exclude flowing liquids and contaminants.
- Reversible rear door is secured with slotted quarter turn fasteners.
- Door frames have zinc die-cast corners with extrusion pressed aluminum profiles.
- Door front panels are 3mm aluminum.
- Oil resistant gaskets are permanently secured.
- Bonding stud provided on door and grounding stud installed in enclosure.
- Quarter turn latches formed from mild steel.
- Formed steel hinge with stainless steel hinge pins.
- Fastening is recommended with optional Tara Plus or 50/80 suspension systems.
- Optional red handle easily mounts horizontally to bottom of enclosure front frame. Order separately.
- Heavy duty re-inforcing plate included.
Finish
- Finished in RAL 7040 gray powder coating.
- Door panel is natural aluminum.
Accessories
- Optional Inner Panel
- Optional Handle
- Window Kits
- Tara Plus Suspension System
- Heavy Duty 50/80 mm Suspension Systems
- Climate Control
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Optional Panel Part No. H W D Part No. ECP12126 12.00 12.00 6.00 ECPP1212 ECP12168 12.00 16.00 8.00 ECPP1216 ECP161610 16.00 16.00 10.00 ECPP1616 ECP162010 16.00 20.00 10.00 ECPP1620 ECP20246 20.00 24.00 6.00 ECPP2024 ECP202412 20.00 24.00 12.00 ECPP2024 SKU: ECPP1620 -
Discontinued Products
Eclipse Command System – NEMA 12 ECP Series – (ECPP1616) (DISCONTINUED)
Application
- Designed to enclose electronic controls, instruments and components in indoor environments where dirt, dust, oil and water may be present.
- Ideal for use with suspension systems.
- Multiple mounting provisions and full front mounting space provide for ideal operator interface.
- Smooth flush surfaces and attractive finishes compliment high tech equipment.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12 and 13
- IEC 60529, IP54
Construction
- Formed from 16 gauge steel.
- Smooth, continuously welded seams ground smooth.
- Door stiffeners are designed to also permit additional mounting options.
- Formed lip on enclosure to exclude flowing liquids and contaminants.
- Reversible rear door is secured with slotted quarter turn fasteners.
- Door frames have zinc die-cast corners with extrusion pressed aluminum profiles.
- Door front panels are 3mm aluminum.
- Oil resistant gaskets are permanently secured.
- Bonding stud provided on door and grounding stud installed in enclosure.
- Quarter turn latches formed from mild steel.
- Formed steel hinge with stainless steel hinge pins.
- Fastening is recommended with optional Tara Plus or 50/80 suspension systems.
- Optional red handle easily mounts horizontally to bottom of enclosure front frame. Order separately.
- Heavy duty re-inforcing plate included.
Finish
- Finished in RAL 7040 gray powder coating.
- Door panel is natural aluminum.
Accessories
- Optional Inner Panel
- Optional Handle
- Window Kits
- Tara Plus Suspension System
- Heavy Duty 50/80 mm Suspension Systems
- Climate Control
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Optional Panel Part No. H W D Part No. ECP12126 12.00 12.00 6.00 ECPP1212 ECP12168 12.00 16.00 8.00 ECPP1216 ECP161610 16.00 16.00 10.00 ECPP1616 ECP162010 16.00 20.00 10.00 ECPP1620 ECP20246 20.00 24.00 6.00 ECPP2024 ECP202412 20.00 24.00 12.00 ECPP2024 SKU: ECPP1616 -
Discontinued Products
Eclipse Command System – NEMA 12 ECP Series – (ECPP1216) (DISCONTINUED)
Application
- Designed to enclose electronic controls, instruments and components in indoor environments where dirt, dust, oil and water may be present.
- Ideal for use with suspension systems.
- Multiple mounting provisions and full front mounting space provide for ideal operator interface.
- Smooth flush surfaces and attractive finishes compliment high tech equipment.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12 and 13
- IEC 60529, IP54
Construction
- Formed from 16 gauge steel.
- Smooth, continuously welded seams ground smooth.
- Door stiffeners are designed to also permit additional mounting options.
- Formed lip on enclosure to exclude flowing liquids and contaminants.
- Reversible rear door is secured with slotted quarter turn fasteners.
- Door frames have zinc die-cast corners with extrusion pressed aluminum profiles.
- Door front panels are 3mm aluminum.
- Oil resistant gaskets are permanently secured.
- Bonding stud provided on door and grounding stud installed in enclosure.
- Quarter turn latches formed from mild steel.
- Formed steel hinge with stainless steel hinge pins.
- Fastening is recommended with optional Tara Plus or 50/80 suspension systems.
- Optional red handle easily mounts horizontally to bottom of enclosure front frame. Order separately.
- Heavy duty re-inforcing plate included.
Finish
- Finished in RAL 7040 gray powder coating.
- Door panel is natural aluminum.
Accessories
- Optional Inner Panel
- Optional Handle
- Window Kits
- Tara Plus Suspension System
- Heavy Duty 50/80 mm Suspension Systems
- Climate Control
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Optional Panel Part No. H W D Part No. ECP12126 12.00 12.00 6.00 ECPP1212 ECP12168 12.00 16.00 8.00 ECPP1216 ECP161610 16.00 16.00 10.00 ECPP1616 ECP162010 16.00 20.00 10.00 ECPP1620 ECP20246 20.00 24.00 6.00 ECPP2024 ECP202412 20.00 24.00 12.00 ECPP2024 SKU: ECPP1216 -
Discontinued Products
Eclipse Command System – NEMA 12 ECP Series – (ECPP1212) (DISCONTINUED)
Application
- Designed to enclose electronic controls, instruments and components in indoor environments where dirt, dust, oil and water may be present.
- Ideal for use with suspension systems.
- Multiple mounting provisions and full front mounting space provide for ideal operator interface.
- Smooth flush surfaces and attractive finishes compliment high tech equipment.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12 and 13
- IEC 60529, IP54
Construction
- Formed from 16 gauge steel.
- Smooth, continuously welded seams ground smooth.
- Door stiffeners are designed to also permit additional mounting options.
- Formed lip on enclosure to exclude flowing liquids and contaminants.
- Reversible rear door is secured with slotted quarter turn fasteners.
- Door frames have zinc die-cast corners with extrusion pressed aluminum profiles.
- Door front panels are 3mm aluminum.
- Oil resistant gaskets are permanently secured.
- Bonding stud provided on door and grounding stud installed in enclosure.
- Quarter turn latches formed from mild steel.
- Formed steel hinge with stainless steel hinge pins.
- Fastening is recommended with optional Tara Plus or 50/80 suspension systems.
- Optional red handle easily mounts horizontally to bottom of enclosure front frame. Order separately.
- Heavy duty re-inforcing plate included.
Finish
- Finished in RAL 7040 gray powder coating.
- Door panel is natural aluminum.
Accessories
- Optional Inner Panel
- Optional Handle
- Window Kits
- Tara Plus Suspension System
- Heavy Duty 50/80 mm Suspension Systems
- Climate Control
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Optional Panel Part No. H W D Part No. ECP12126 12.00 12.00 6.00 ECPP1212 ECP12168 12.00 16.00 8.00 ECPP1216 ECP161610 16.00 16.00 10.00 ECPP1616 ECP162010 16.00 20.00 10.00 ECPP1620 ECP20246 20.00 24.00 6.00 ECPP2024 ECP202412 20.00 24.00 12.00 ECPP2024 SKU: ECPP1212 -
Discontinued Products
Type 4, 4X Polycarbonate Pushbutton Enclosure 1554 PB Series – (1554YPL) (DISCONTINUED)
Discontinued ProductsType 4, 4X Polycarbonate Pushbutton Enclosure 1554 PB Series – (1554YPL) (DISCONTINUED)
Standards
- IP66
- NEMA 4, 4X, 6, 6P, 12 & 13
- 6 pushbutton enclosures do not meet Type 6/6P
- UL94 5VA
Construction
- Electronic instrument enclosures, designed for mounting printed circuit boards or DIN rail mounted components.
- The polycarbonate material carries a UL flammability rating of UL94 5V and is suitable for outdoor use.
- Lid and mounting holes are located outside of the gasket seal.
- Lid is secured with self captivating M4 stainless steel machine screws (included), threaded into integral stainless steel bushings (for repetitive assembly & disassembly).
- Heavy duty 16 gauge galvanized steel panels available (see chart)
- All stainless steel hardware to avoid corrosion caused by dissimilar metals.
- Gasket is a preformed, high temperature U.L. listed silicone rubber. Gasket is replaceable.
- Gasketed lid with two piece “tongue & groove” construction provides protection against access of oil, dust and water.
- Internal DIN rail mounting tabs.
- Threaded (M3) integral brass inserts & standoffs designed for M3.5 or #6 self tapping screws for P.C. board or inner panel mounting in all but the smallest size.
- Vertical P.C. card guides (for 1.5 mm thick P.C. boards) are molded in all but the smallest size
Finish
- Color is light gray (RAL 7035)
Accessories
- Optional Inner Panel
- Heavy duty panels for mounting components
- Galvanized 16 ga. steel.
- Includes mounting hardware.
- Optional Mounting Feet
- Part No. 1554FT
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)