1874A – Category 6+ Cable, 4 Bonded-Pairs, U/UTP, CMP


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE
Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor
Size Stranding Material No. of Pairs
23 AWG Solid BC – Bare Copper 4
Insulation
Material Color Code
FEP – Fluorinated Ethylene Propylene White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Bonded-Pair: Yes
Outer Jacket
Material Material Trade Name Nom. Diameter Ripcord
PVC – Polyvinyl Chloride Flamarrest® 0.365 x 0.165 in Yes
Overall Cable Diameter (Nominal): 0.365 x 0.165 in

Electrical Characteristics

Electricals
Max. Conductor DCR Max. Capacitance Unbalance
75 Ohm/km (23 Ohm/1000ft) 49 pF/100m
Delay
Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
100 MHz 537.6 ns/100m 25 ns/100m 72%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) [Ohm] Max./Min. Fitted Impedance [Ohm]
1 1.9 dB/100m 75.3 75.3 73.4 73.4 67.8 64.8 20.0 100 ± 12 100 ± 15
4 3.7 dB/100m 66.3 66.3 62.6 62.6 55.7 52.8 23.0 100 ± 12 100 ± 15
8 5.3 dB/100m 61.8 61.8 56.5 56.5 49.7 46.7 24.5 100 ± 12 100 ± 15
10 5.9 dB/100m 60.3 60.3 54.4 54.4 47.8 44.8 25.0 100 ± 12 100 ± 15
16 7.5 dB/100m 57.2 57.2 49.7 49.7 43.7 40.7 25.0 100 ± 12 100 ± 8
20 8.4 dB/100m 55.8 55.8 47.3 47.3 41.8 38.8 25.0 100 ± 12 100 ± 8
25 9.5 dB/100m 54.3 54.3 44.9 44.9 39.8 36.8 24.3 100 ± 15 100 ± 8
31.25 10.6 dB/100m 52.9 52.9 42.2 42.2 37.9 34.9 23.6 100 ± 15 100 ± 8
62.5 15.4 dB/100m 48.4 48.4 33.0 33.0 31.8 28.9 21.5 100 ± 15 100 ± 8
100 19.8 dB/100m 45.3 45.3 25.5 25.5 27.8 24.8 21.0 100 ± 15 100 ± 8
155 25.1 dB/100m 42.4 42.4 17.3 17.3 24.0 21.0 21.0 100 ± 15 100 ± 8
200 29.0 dB/100m 40.8 40.8 11.8 11.8 21.7 18.8 21.0 100 ± 15 100 ± 8
250 32.8 dB/100m 39.3 39.3 6.5 6.5 19.8 16.8 18.0 100 ± 20 100 ± 8
300 36.4 dB/100m 38.1 38.1 1.7 1.7 18.3 15.3 18.0 100 ± 20 100 ± 8
310 39.8 dB/100m 37.1 37.1 -2.6 -2.6 16.9 13.9 17.0 100 ± 22 100 ± 8
350 43.0 dB/100m 36.3 36.3 15.8 12.8 14.0 100 ± 32 100 ± 8
400 46.0 dB/100m 35.5 35.5 14.7 11.7 14.0 100 ± 32 100 ± 8
500 48.9 dB/100m 34.8 34.8 13.8 10.8 14.0 100 ± 32 100 ± 8
550 51.8 dB/100m 34.2 34.2 13.0 10.0 14.0 100 ± 32 100 ± 8
Voltage
UL Voltage Rating
300 V (CMP)

Mechanical Characteristics

Temperature
UL Temperature Operating Installation Storage
75°C -20°C To +75°C 0°C To +50°C -20°C To +75°C
Bend Radius
Stationary Min. Installation Min.
0.5 in (13 mm) 1.75 in (44.5 mm)
Max. Pull Tension: 40 lbs (18 kg)
Bulk Cable Weight: 35 lbs/1000ft

Standards and Compliance

Environmental Suitability: Plenum, Indoor
Sustainability: Product Lens™, Environmental Product Declaration (EPD) Available
Flammability / Reaction to Fire: NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca; CPR UKCA Class: Eca
NEC / UL Compliance: Article 800, CMP
CEC / C(UL) Compliance: CMP
ICEA Compliance: S-116-732
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA Compliance: ANSI/NEMA WC-66
Data Category: Category 6
TIA/EIA Compliance: ANSI/TIA-568.2-D Category 6
Third Party Performance Verification: Category 6
ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61156-5
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)
Non-Plenum Number: 1872A

Product Notes

Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 350 MHz are for Engineering Information Only. Print Includes Descending Footage Markings from Max. Put-Up Length to 0.

History

Update and Revision: Revision Number: 0.574 Revision Date: 12-12-2023

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
1874A 0101000 Black Reel 1,000 ft 612825125631 C
1874A D151000 Blue Reel 1,000 ft 612825125488 C
1874A D15A1000 Blue Reel-in-Box 1,000 ft 612825125471
1874A F6H1000 Gray Reel 1,000 ft 612825125501 C
1874A F6HA1000 Gray Reel-in-Box 1,000 ft 612825125495
1874A 005A1000 Green Reel-in-Box 1,000 ft 612825125570
1874A 8771000 Natural Reel 1,000 ft 612825125655 C
1874A 877A1000 Natural Reel-in-Box 1,000 ft 612825125648
1874A 003A1000 Orange Reel-in-Box 1,000 ft 612825125532
1874A 0071000 Purple Reel 1,000 ft 612825125600 C
1874A 007A1000 Purple Reel-in-Box 1,000 ft 612825125594
1874A 002A1000 Red Reel-in-Box 1,000 ft 612825125518
1874A 0091000 White Reel 1,000 ft 612825125624 C
1874A 009A1000 White Reel-in-Box 1,000 ft 612825125617
1874A 004A1000 Yellow Reel-in-Box 1,000 ft 612825125556