Suitable Applications: OSP-Outdoor, CM-LS, Low Smoke, Indoor/Outdoor, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422
Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
24 Solid BC – Bare Copper 4
Conductor Count: 8
Total Number of Pairs: 4
Insulation
Material
PO – Polyolefin
Bonded-Pair: N/A
Color Chart
Number Color
1 White/Blue Stripe & Blue
2 White/Orange Stripe & Orange
3 White/Green Stripe & Green
4 White/Brown Stripe & Brown
Water Penetration: GR 421?CORE para. 4.3.5.1, ANSI/ICEA S?107?704 para. 8.2.1, ANSI/ICEA S-99-689
Outer Jacket
Material Material Trade Name Nominal Diameter Ripcord
LSZH – Low Smoke Zero Halogen (Flame Retardant) Haloarrest® 0.251 in No

Electrical Characteristics

Conductor DCR
Max. Conductor DCR Max. DCR Unbalance
93.8 Ohm/km 5.0 %
Capacitance
Max. Capacitance Unbalance Nom.Mutual Capacitance
330 pF/100m 15 pF/ft
Delay
Frequency [MHz] Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
100 MHz 537.6 ns/100m 45 ns/100m 68%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance
1 MHz 2.0 dB/100m 65.3 dB 62.3 dB 63.3 dB 60.3 dB 63.8 dB 60.8 dB 20.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
4 MHz 4.1 dB/100m 56.3 dB 53.3 dB 52.2 dB 49.2 dB 51.8 dB 48.8 dB 23.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
8 MHz 5.8 dB/100m 51.8 dB 48.8 dB 46.0 dB 43.0 dB 45.7 dB 42.7 dB 24.5 dB 100 ± 15 Ohm 100 ± 15 Ohm
10 MHz 6.5 dB/100m 50.3 dB 47.3 dB 43.8 dB 40.8 dB 43.8 dB 40.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
16 MHz 8.2 dB/100m 47.2 dB 44.2 dB 39.0 dB 36.0 dB 39.7 dB 36.7 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
20 MHz 9.3 dB/100m 45.8 dB 42.8 dB 36.5 dB 33.5 dB 37.8 dB 34.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
25 MHz 10.4 dB/100m 44.3 dB 41.3 dB 33.9 dB 30.9 dB 35.8 dB 32.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 15 Ohm
31.25 MHz 11.7 dB/100m 42.9 dB 39.9 dB 31.2 dB 28.2 dB 33.9 dB 30.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 15 Ohm
62.5 MHz 17.0 dB/100m 38.4 dB 35.4 dB 21.4 dB 18.4 dB 27.9 dB 24.9 dB 21.5 dB 100 ± 15 Ohm 100 ± 15 Ohm
100 MHz 22.0 dB/100m 35.3 dB 32.3 dB 13.3 dB 10.3 dB 23.8 dB 20.8 dB 20.1 dB 100 ± 15 Ohm 100 ± 15 Ohm
155 MHz 28.1 dB/100m 32.4 dB 29.4 dB 4.4 dB 1.4 dB 20.0 dB 17.0 dB 18.8 dB
200 MHz 32.4 dB/100m 30.8 dB 27.8 dB 17.8 dB 14.8 dB 18.0 dB
Voltage
UL Voltage Rating
300 V RMS

Temperature Range

Installation Temperature Range: -20°C To +75°C
UL Temp Rating: 75°C
Storage Temperature Range: -40°C To +75°C
Operating Temperature Range: -40°C To +75°C

Mechanical Characteristics

Cold Bend Test: -20°C Compliance per UL 1581
Bulk Cable Weight: 35 lbs/1000ft
Max. Pull Tension: 25 lbs
Min. Bend Radius During Installation: 2.5 in
Min. Bend Radius/Minor Axis: 1.0 in

Standards

NEC/(UL) Compliance: CM-LS
CEC/C(UL) Compliance: CM-LS
ISO/IEC Compliance: 11801 ed 2.2 (2011) Class D
Data Category: Category 5e
ANSI Compliance: S-90-661-2012 Category 5e, ANSI/NEMA WC-63.1 Category 5e
TIA/EIA Compliance: ANSI/TIA-568-C.2 Category 5e
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3

Applicable Environmental and Other Programs

Environmental Space: Indoor/Outdoor
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: Yes
EU CE Mark: Yes
EU REACH SVHC Compliance (yyyy-mm-dd): 2017-07-10

Suitability

Suitability – Aerial: Yes – When supported by messenger wire
Suitability – Burial: Yes – Engineered burial only
Suitability – Hazardous Locations: No
Suitability – Indoor: Yes
Suitability – Non-Halogenated: Yes
Suitability – Oil Resistance: No
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL 1685 (UL Loading-Limited Smoke)
UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): No

Related Part Numbers

Variants
Item # Color UPC
2137A 0101000 Black 612825321255

Product Notes

Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values over 100 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Suitable for use in Buildings in Wet Locations. Not Suitable for Direct Burial. Fully Water Blocked and Sunlight Resistant (Black Jacket Only).

History

Update and Revision: Revision Number: 0.321 Revision Date: 12-12-2023