2142A – Category 6A Indoor/Outdoor Cable, 4 Pair, F/UTP, CMR/CMX


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Indoor/Outdoor, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, Noisy Enivronments, HDBaseT
Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor
Size Stranding Material No. of Pairs
23 AWG Solid BC – Bare Copper 4
Insulation
Material Color Code
PO – Polyolefin White & Blue, White & Orange, White & Green, White & Brown
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 26 AWG (7×34) TC
Outer Jacket
Separator Material Nom. Diameter Ripcord
Center Member (Patented EquiSpline®) PVC – Polyvinyl Chloride 0.300 in (7.62 mm) Yes
Overall Cable Diameter (Nominal): 0.300 in (7.62 mm)

Electrical Characteristics

Electricals
Max. Conductor DCR Max. Capacitance Unbalance
82 Ohm/km (25 Ohm/1000ft) 45 pF/100m
Delay
Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
100 MHz 537.6 ns/100m 45 ns/100m 65%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. PSNEXT [dB] Min. PSACR [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) [Ohm] Max./Min. Fitted Impedance [Ohm] Min. PSANEXT [dB] Min. PSAACRF [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 2.1 dB/100m 75.3 73.2 79.8 20.0 100 ± 15 105 ± 10 75.0 77.0 40.0 43.0
4 3.8 dB/100m 66.3 62.5 67.8 23.0 100 ± 15 100 ± 15 75.0 76.2 40.0 41.0
8 5.3 dB/100m 61.8 56.5 61.7 24.5 100 ± 15 100 ± 15 75.0 70.1 40.0 24.9
10 5.9 dB/100m 60.3 54.4 59.8 25.0 100 ± 15 100 ± 15 75.0 68.2 40.0 23.0
16 7.4 dB/100m 57.2 49.8 55.7 25.0 100 ± 15 100 ± 15 75.0 64.1 38.0 18.9
20 8.3 dB/100m 55.8 47.4 53.8 25.0 100 ± 15 100 ± 15 75.0 62.2 37.0 17.0
25 9.3 dB/100m 54.3 45.0 51.8 24.3 100 ± 15 100 ± 15 75.0 60.2 36.0 15.0
31.25 10.4 dB/100m 52.9 42.5 49.9 23.6 100 ± 15 100 ± 10 75.0 58.3 35.1 13.1
62.5 14.8 dB/100m 48.4 33.6 43.9 21.5 100 ± 15 100 ± 10 73.6 52.3 32.0
100 18.9 dB/100m 45.3 26.4 39.8 20.1 100 ± 15 100 ± 10 70.5 48.2 30.0
200 27.0 dB/100m 40.8 13.8 33.8 18.9 100 ± 22 100 ± 10 66.0 42.2 27.0
250 30.4 dB/100m 39.3 9.0 31.8 17.3 100 ± 32 100 ± 10 64.5 40.2 26.0
300 33.5 dB/100m 38.1 4.6 30.3 16.8 100 ± 32 100 ± 10 63.3 38.7 25.2
350 36.3 dB/100m 37.1 0.8 28.9 16.3 100 ± 32 100 ± 10 62.3 37.3 24.6
400 39.0 dB/100m 36.3 27.8 15.9 100 ± 32 100 ± 10 61.5 36.2 24.0
450 41.5 dB/100m 35.5 26.7 15.5 100 ± 32 100 ± 10 60.7 35.1 23.5
500 43.9 dB/100m 34.8 25.8 15.2 100 ± 32 100 ± 10 60.0 34.2 23.0
550 46.2 dB/100m 33.2 25.0 14.9 100 ± 32 100 ± 10 59.4 33.4
600 48.4 dB/100m 32.6 24.2 14.7 100 ± 32 100 ± 10 58.8 32.6
625 49.5 dB/100m 32.4 23.9 14.5 100 ± 32 100 ± 10 58.6 32.3
750 54.7 dB/100m 32.2 22.3 14.0 100 ± 32 100 ± 10 57.4 30.7
860 58.9 dB/100m 31.3 21.1 13.6 100 ± 32 100 ± 10 56.5 29.5
Voltage
UL Voltage Rating
300 V (CMR), 300 V (CMX-Outdoor)

Mechanical Characteristics

Temperature
UL Temperature Operating Installation Storage
90°C -40°C To +75°C -20°C To +75°C -40°C To +75°C
Bend Radius
Stationary Min. Installation Min.
2.5 in (64 mm) 3.0 in (76 mm)
Max. Pull Tension: 25 lbs (11 kg)
Bulk Cable Weight: 42 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Aerial – When supported by messenger wire
Flammability / Reaction to Fire: UL 1666 Riser, FT4, IEEE 1202 Vertical Tray Flame Test
NEC / UL Compliance: Article 800, CMR, CMX-Outdoor
CEC / C(UL) Compliance: CMX-Outdoor
ICEA Compliance: S-116-732, S-56-434, S-99-689, S-100-685
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA Compliance: ANSI/NEMA WC-66
Data Category: Category 6A
TIA/EIA Compliance: ANSI/TIA-568.2-D Category 6A
ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61156-5
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC Compliance: China RoHS II (GB/T 26572-2011)
Plenum Number: 10GX53F / 10GX63F
Non-Plenum Number: 10GX52F / 10GX62F

Product Notes

Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 625MHz for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0.

History

Update and Revision: Revision Number: 0.328 Revision Date: 12-12-2023

Part Numbers

Variants
Item # Color UPC
2142A 0101000 Black 612825401056

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)