Product Overview
Suitable Applications: | Variable Frequency Drives (VFD); AC Motor and Drive Systems |
Construction Details
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 3 | 10 AWG | 105×30 | TC – Tinned Copper |
Ground Wire | 1 | 10 AWG | 105×30 | TC – Tinned Copper |
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | XLPE – Cross-Linked Polyethylene (Thermoset) | 0.046 in (1.2 mm) | 0.212 in (5.38 mm) | ICEA Chart M4 |
Ground Wire | PVC – Polyvinyl Chloride | 0.046 in (1.2 mm) | 0.212 in (5.38 mm) | Green/Yellow Stripe |
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Tri-Laminate (Alum+Poly+Alum) | 100% | 10 AWG (105×30) TC |
Braid | Tinned Copper (TC) | 85% |
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|---|---|---|
PVC – Polyvinyl Chloride | 0.073 in (1.9 mm) | 0.690 in (17.5 mm) | Yes |
Overall Cable Diameter (Nominal): | 0.690 in (17.5 mm) |
Electrical Characteristics
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|---|
Conductor(s) | 0.969 Ohm/1000ft | 23 pF/ft (75 pF/m) | 42 pF/ft (140 pF/m) | 80 Ohm | 55% | 40 Amps per Conductor at 30ºC (per NEC) |
1.080 Ohm/1000ft (3.543 Ohm/km) | 40 Amps per Conductor at 30ºC (per NEC) |
UL Voltage Rating | Voltage Rating |
---|---|
1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) | 1000 V (AWM I/II A/B) |
Mechanical Characteristics
UL Temperature | Operating |
---|---|
90°C Dry, 90°C Wet | -40°C To +90°C |
Stationary Min. | Installation Min. |
---|---|
8.3 in (210 mm) | 8.3 in (210 mm) |
Max. Pull Tension: | 762 lbs (346 kg) |
Bulk Cable Weight: | 353 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance, Burial |
Sustainability: | CA Prop 65 |
Flammability / Reaction to Fire: | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
NEC / UL Compliance: | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
AWM Compliance: | AWM I/II A/B |
CEC / C(UL) Compliance: | CIC, TC |
ICEA Compliance: | S-95-658 |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Other Standard Compliance(s): | P-07-KA070003-MSHA |
History
Update and Revision: | Revision Number: 0.606 Revision Date: 12-22-2023 |
Part Numbers
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
29503 010100 | Black | Reel | 100 ft | 612825136880 | |
29503 010250 | Black | Reel | 250 ft | 612825136910 | C Z |
29503 010500 | Black | Reel | 500 ft | 612825136941 | C Z |
29503 0101000 | Black | Reel | 1,000 ft | 612825136897 | C Z |
29503 0105000 | Black | Reel | 5,000 ft | 612825136958 | C Z |