Product Overview
Suitable Applications: | Intercom/PA systems, Sound/Audio systems |
Construction Details
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 2 | 12 AWG | 19×25 | TC – Tinned Copper |
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | PVC – Polyvinyl Chloride | 0.014 in (0.36 mm) | 0.119 in (3.02 mm) | Black, White |
Material |
---|
No Shield |
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.025 in (0.64 mm) | 0.320 in |
Overall Cable Diameter (Nominal): | 0.320 in |
Electrical Characteristics
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Max. Current |
---|---|---|
1.7 Ohm/1000ft | 32 pF/ft (100 pF/m) | 12 Amps per Conductor at 25ºC |
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
UL Temperature | Operating |
---|---|
105°C | -30°C to 105°C |
Stationary Min. | Installation Min. |
---|---|
3.2 in (81 mm) | 3.2 in |
Max. Pull Tension: | 152 lbs (68.9 kg) |
Bulk Cable Weight: | 59 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Outdoor – Water Exposure, Indoor, Outdoor |
Flammability / Reaction to Fire: | UL1685 UL Loading |
NEC / UL Compliance: | Article 725, CL3 |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
History
Update and Revision: | Revision Number: 0.395 Revision Date: 03-04-2024 |
Part Numbers
Item # | Color | Putup Type | Length | UPC |
---|---|---|---|---|
5000U1 0101000 | Black | Reel | 1,000 ft | 612825154785 |
5000U1 0081000 | Gray | Reel | 1,000 ft | 612825154778 |