Product Overview
Suitable Applications: | Intercom/PA Systems, Sound/Audio Systems |
Construction Details
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Triad(s) | 1 | 20 AWG | 7×28 | TC – Tinned Copper |
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Triad(s) | PP – Polypropylene | 0.008 in (0.20 mm) | 0.054 in (1.4 mm) | Black & Red & White |
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (Solid) TC |
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|---|---|---|
PVC – Polyvinyl Chloride | 0.017 in (0.43 mm) | 0.149 in | Yes |
Overall Cable Diameter (Nominal): | 0.149 in |
Electrical Characteristics
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
---|---|---|---|
11.1 Ohm/1000ft | 38 pF/ft (120 pF/m) | 65 pF/ft (210 pF/m) | 3.75 Amps per Conductor at 25ºC |
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
UL Temperature | Operating |
---|---|
75°C | -20°C To +75°C |
Stationary Min. | Installation Min. |
---|---|
1.49 in (37.8 mm) | 1.49 in |
Max. Pull Tension: | 42.9 lbs (19.5 kg) |
Bulk Cable Weight: | 17 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor – Riser, Indoor |
Flammability / Reaction to Fire: | UL1666 Riser, FT4 |
NEC / UL Compliance: | Article 800, CMR |
CEC / C(UL) Compliance: | CMG |
European Directive Compliance: | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Plenum Number: | 6401FH |
History
Update and Revision: | Revision Number: 0.62 Revision Date: 03-04-2024 |
Part Numbers
Item # | Color | Putup Type | Length | UPC |
---|---|---|---|---|
5401FH 0081000 | Gray | Reel | 1,000 ft | 612825162063 |
5401FH 008U1000 | Gray | UnReel | 1,000 ft | 612825162100 |