Product Overview
Suitable Applications: | Speaker cable for use in indoor or outdoor applications |
Physical Characteristics (Overall)
Stranding | Material | Cross Section | Construction n x D |
---|---|---|---|
Stranded | BC-OFHC – Oxygen-Free Bare Copper (High Conductivity) | 1.50 mm² | 30×0.25 mm |
Conductor Count: | 2 |
Type | Material | Nominal Diameter | Diameter +/- Tolerance |
---|---|---|---|
Insulation | LSZH – Low Smoke Zero Halogen (Flame Retardant) | 2.30 mm | 0.07 mm |
Number | Color |
---|---|
Wire 1 | Black |
Wire 2 | Red |
Material | Nominal Diameter | Diameter +/- Tolerance |
---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 6.80 mm | 0.25 mm |
Table Notes: | Flexible with Matte Finish |
Construction and Dimensions
Description |
---|
2 wires twisted |
Electrical Characteristics
Max. Conductor DCR |
---|
13 Ohm/km |
Min Insulation Resistance: | 200 MOhm*km |
Voltage Rating [V] |
---|
300 V |
Temperature Range
Storage Temperature Range: | -30°C to +70°C |
Operating Temp Range (Flexible Install): | -5°C To +60°C |
Operating Temp Range (Fixed Install): | -30°C To +70°C |
Mechanical Characteristics
Max. Pull Tension: | 200 N |
Standards
CPR Euroclass: | Cca-s1,d1,a1 |
Applicable Environmental and Other Programs
Environmental Space: | Indoor/Outdoor – Euroclass Cca |
Flammability, LS0H, Toxicity Testing
IEC Flammability: | IEC 60332-1-2 |
IEC 60754-1 – Halogen Amount: | Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
Related Part Numbers
Item # | Color | Put-Up Type | Length | EAN |
---|---|---|---|---|
70045LW.00500 | Black | Reel | 500 m | 8719605170378 |
History
Update and Revision: | Revision Number: 0.62 Revision Date: 02-15-2024 |