7834BNC – Category 6+ Cable, 4 Bonded-Pairs, U/UTP, LSZH Jkt, Indoor


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base – T (Gigabit Ethernet), 100 Base – T, 10Base – T, FDDI, ATM

Construction Details

Conductor
Size Stranding Material No. of Pairs
23 AWG Solid BC – Bare Copper 4
Insulation
Material Nom. Insulation Diameter Color Code
PE – Polyethylene 1.15 mm (0.0453 in) Blue & White with Blue Strip, Orange & White with Orange Strip, Green & White with Green Strip, Brown & White with Brown Strip
Bonded-Pair: Yes
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant) 6.3 mm (0.25 in)

Electrical Characteristics

Electricals
Max. Conductor DCR Max. Mutual Capacitance Max. Capacitance Unbalance Nom. Characteristic Impedance
95 Ohm/km 56 pF/m (17 pF/ft) 160 pF/100m 100 Ohm
Delay
Max. Delay Skew Nom. Velocity of Prop.
40 ns/100m 67%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) [dB/100m] Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 2.0 80.3 78.3 78.3 76.3 74 71 23 40 35
4 3.7 71.3 69.3 67.6 65.6 62 59 26 34 23
10 5.7 65.3 63.3 59.6 57.6 54 51 28 30 15
16 7.2 62.2 60.2 55.0 53.0 49.9 46.9 28 28 10.9
31.3 10.2 57.9 55.9 47.7 45.7 44.1 41.1 26.6 25.1 5.1
62.5 14.6 53.4 51.4 38.8 36.8 38.1 35.1 24.5 22
100 18.8 50.3 48.3 31.5 29.5 34 31 23.1 20
125 21.2 48.8 46.8 27.6 25.6 32.1 29.1 22.4 19
200 27.4 45.8 43.8 18.4 16.4 28 25 21 17
250 31.1 44.3 42.3 13.2 11.2 26 23 20.3 16
350 37.6 42.1 40.1 23.1 20.1 19.3
500 46.3 39.8 37.8 20 17 19.3
650 54.0 38.1 36.1 17.7 14.7 19.3
Table Notes: The cable performance between 1 MHz and 4 MHz,Frequency range exceeding 250MHz is achieved by design only and it is therefore not necessary to test for this performance below 4 MHz. Reference standard: ISO/IEC 61156-5
ed. 2.0 (2009)
The value of transmission performance is typical.

Mechanical Characteristics

Temperature
Operating
-30°C To +60°C
Bend Radius
Installation Min.
8*D
Bulk Cable Weight: 46 kg/km (31 lbs/1000ft)

Standards and Compliance

Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-3-22
ISO/IEC Compliance: IEC 61156-5, ISO/IEC 11801, IEC 61034-2 – Smoke Density Min Transmittance = 60%
CENELEC Compliance: EN 50173-1
European Halogen Free Standards: IEC 60754-1 – Halogen Amount = HCL+HBr ? 0.5%, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3

History

Update and Revision: Revision Number: 0.20 Revision Date: 12-12-2023

Part Numbers

Variants
Item # Color Putup Type Length
7834BNC 006A1000 Blue Reel in Box 1,000 ft
7834BNC 006U1000 Blue Unreel 1,000 ft
7834BNC 008U1000 Gray Unreel 1,000 ft
7834BNC 008A1000 Gray Reel in Box 1,000 ft