Suitable Applications: rs-232 extended distance applications; rs-422 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, …); low voltage digital control (24v, …); line level audio; panel wiring

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Pair(s) 2 24 AWG 7×32 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) PE – Polyethylene (Foam) 0.013 in (0.33 mm) 0.049 in (1.2 mm) Western Electric Standard
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 24 AWG (7×32) TC
Braid Tinned Copper (TC) 65%
Outer Jacket
Material Nom. Thickness Nom. Diameter
PVC – Polyvinyl Chloride 0.035 in (0.89 mm) 0.270 in (6.86 mm)
Overall Cable Diameter (Nominal): 0.270 in (6.86 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Pair(s) 24 Ohm/1000ft 12.5 pF/ft (41.0 pF/m) 22 pF/ft (72 pF/m) 100 Ohm 78% 1.8 Amps per Conductor at 25ºC
Voltage
UL Voltage Rating
300 V (CM), 30 V (UL AWM 2919)

Mechanical Characteristics

Temperature
UL Temperature Operating
80°C -30°C to +80°C
Bend Radius
Stationary Min. Installation Min.
2.7 in (69 mm) 2.7 in (69 mm)
Max. Pull Tension: 36 lbs (16 kg)
Bulk Cable Weight: 34 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor (Not Riser or Plenum), Indoor
Flammability / Reaction to Fire: UL 1685 FT4 Loading, IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca; CPR UKCA Class: Eca
NEC / UL Compliance: Article 800, CM
AWM Compliance: AWM 2919
CEC / C(UL) Compliance: CM
European Directive Compliance: EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)
Plenum Number: 88102

Product Notes

Notes: Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight.

History

Update and Revision: Revision Number: 0.501 Revision Date: 12-22-2023

Part Numbers

Variants
Item # Color Putup Type Length UPC/EAN Footnote
8102.0030 Chrome Reel 30 m 8719605017680
8102 060100 Chrome Reel 100 ft 612825194743
8102.01152 Chrome Reel 152 m 8719605017703
8102.00305 Chrome Reel 305 m 8719605017697
8102 060500 Chrome Reel 500 ft 612825194774 C
8102 0601000 Chrome Reel 1,000 ft 612825194750 C
8102.001000 Chrome Reel 1,000 m 8719605017673
8102 0605000 Chrome Reel 5,000 ft 612825194781 C
8102 06010000 Chrome Reel 10,000 ft 612825194767 C Y

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)