Suitable Applications: RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, …); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Pair(s) 2 24 AWG 7×32 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) FEP – Fluorinated Ethylene Propylene (Foam) 0.019 in (0.48 mm) 0.062 in (1.6 mm) White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 24 AWG (7×32) TC
Braid Tinned Copper (TC) 90%
Outer Jacket
Material Nom. Thickness Nom. Diameter
PVC – Polyvinyl Chloride 0.015 in (0.38 mm) 0.273 in (6.93 mm)
Overall Cable Diameter (Nominal): 0.273 in (6.93 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Pair(s) 24 Ohm/1000ft 12 pF/ft (39 pF/m) 22 pF/ft 120 Ohm 76% 3.2 Amps per Conductor at 25ºC
Nom. Outer Shield DCR: 2.4 Ohm/1000ft (7.9 Ohm/km)
High Frequency (Nominal/Typical)
Element Frequency [MHz] Nom. Insertion Loss (Attenuation)
Pair(s) 1 0.6 dB/100ft
Voltage
UL Voltage Rating
300 V (CMP)

Mechanical Characteristics

Temperature
UL Temperature Operating
75°C 0°C to +75°C
Bend Radius
Stationary Min. Installation Min.
2.75 in (69.9 mm) 2.75 in (69.9 mm)
Max. Pull Tension: 56.7 lbs (25.7 kg)
Bulk Cable Weight: 38 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor
Flammability / Reaction to Fire: NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca
NEC / UL Compliance: Article 800, CMP
CEC / C(UL) Compliance: CMP
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)
Non-Plenum Number: 9842

History

Update and Revision: Revision Number: 0.540 Revision Date: 12-22-2023

Part Numbers

Variants
Item # Color UPC Footnote
82842 8771000 Natural 612825198192 C
82842 877500 Natural 612825198208 C
82842 8775000 Natural 612825198215

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)