8762ELV – Electronic, 2 C #20 Str TC, PE ins, OS, LSNH Jkt, 300V, B2ca


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Instrumentation and computer cable; For data transmission applications

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
20 7×28 TC – Tinned Copper 1
Conductor Count: 2
Insulation
Material Nominal Diameter Diameter +/- Tolerance Nominal Wall Thickness
PE – Polyethylene 1.78 mm 0.05 mm 0.016 in
Color Chart
Number Color
Pair 1 Black & Clear
Outer Shield
Type Material Material Trade Name Coverage [%] Thickness of Foil Drainwire Material Drainwire AWG Drainwire Construction n x D
Tape Bi-Laminate (Alum+Poly) Beldfoil® (Z-Fold®) 100% 9 / 12 µm TC – Tinned Copper AWG20/7 7×28
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH – Low Smoke Zero Halogen (Flame Retardant) 6.0 mm 1.15 mm

Construction and Dimensions

Stranding
Twists
6 twist/ft

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
31.2 Ohm/km
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
88.6 pF/m 160.8 pF/m
Inductance
Nominal Inductance Nominal Pair Inductance
0.18 µH/ft 0.591 µH/m
Impedance
Nominal Characteristic Impedance
56 Ohm
Delay
Nominal Velocity of Propagation (VP) [%]
66%
Current
Element Max. Recommended Current [A]
Conductor(s) 3.9 Amps per Conductor
Voltage
Voltage Rating [V]
300 V

Temperature Range

Installation Temperature Range: -15°C To +80°C
Storage Temperature Range: -45°C To +80°C
Operating Temp Range (Flexible Install): -15°C To +80°C
Operating Temp Range (Fixed Install): -45°C To +80°C

Mechanical Characteristics

Oil Resistance: IEC 60811-404
Max. Pull Tension: 210 N
Min. Bend Radius During Installation: 60 mm
Min. Bend Radius/Minor Axis: 2 in

Standards

CPR Euroclass: B2ca-s1,d1,a1
CENELEC Compliance: EN 50290-2-20

Applicable Environmental and Other Programs

Environmental Space: Indoor – Euroclass B2ca
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Indoor: Yes
Suitability – Non-Halogenated: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

IEC Flammability: IEC 60332-1-2
IEC 60754-1 – Halogen Amount: Zero
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 2.5 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
IEC 61034-2 – Smoke Density Min. Transmittance: 60%

Plenum/Non-Plenum

Plenum (Y/N): No

History

Update and Revision: Revision Number: 0.35 Revision Date: 02-15-2024