Product Overview
Suitable Applications: | extreme high/low temperature environments; chemical resistant; outdoor and burial applications; low voltage analog signals (4-20ma, 0-10v, …); low voltage control (24v, ); line level audio; voice communications; panel wiring |
Construction Details
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 4 | 18 | 19×30 | TC – Tinned Copper |
Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|
FEP – Fluorinated Ethylene Propylene | 0.0065 in (0.17 mm) | 0.042 in (1.1 mm) | Black, White, Red, Green |
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
FEP – Fluorinated Ethylene Propylene | 0.009 in (0.23 mm) | 0.156 in |
Electrical Characteristics
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Max. Current |
---|---|---|
6.4 Ohm/1000ft | 21 pF/ft (69 pF/m) | 11.52 Amps per Conductor at 25ºC |
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
Operating |
---|
-70°C To +200°C |
Stationary Min. | Installation Min. |
---|---|
1.56 in (39.6 mm) | 1.56 in |
Max. Pull Tension: | 82 lbs (37 kg) |
Bulk Cable Weight: | 28 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Outdoor, Burial |
Flammability / Reaction to Fire: | NFPA 262 |
CPR Compliance: | CPR Euroclass: Eca |
NEC / UL Compliance: | Article 800, CL3P, CMP |
CEC / C(UL) Compliance: | CMP |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance: | UKCA Mark |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Non-Plenum Number: | 8489 |
History
Update and Revision: | Revision Number: 0.358 Revision Date: 11-27-2023 |
Part Numbers
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
88489 0021000 | Red | Reel | 1,000 ft | 612825217046 | C |