Product Overview
Suitable Applications: | Thick Ethernet (IEEE 802.3 10BASE5) |
Construction Details
Size | Stranding | Nom. Diameter | Material |
---|---|---|---|
12 AWG | Solid | 0.086 in | BC – Bare Copper |
Material | Nom. Insulation Diameter | Color Code |
---|---|---|
FEP – Fluorinated Ethylene Propylene (Foam) | 0.245 in (6.22 mm) | Clear |
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|---|---|---|---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
2 | Braid | Tinned Copper (TC) | 90% | |
3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
4 | Braid | Tinned Copper (TC) | 90% |
Material | Nom. Diameter |
---|---|
PVDF – Polyvinylidene Fluoride | 0.365 in (9.27 mm) |
Overall Cable Diameter (Nominal): | 0.365 in (9.27 mm) |
Electrical Characteristics
Frequency | Nom. Attenuation |
---|---|
1 MHz | 0.18 dB/100ft |
5 MHz | 0.37 dB/100ft |
10 MHz | 0.52 dB/100ft |
50 MHz | 1.15 dB/100ft |
100 MHz | 1.65 dB/100ft |
200 MHz | 2.45 dB/100ft |
400 MHz | 3.80 dB/100ft |
700 MHz | 5.60 dB/100ft |
900 MHz | 6.80 dB/100ft |
1000 MHz | 7.20 dB/100ft |
Frequency | Max. Power Rating |
---|---|
1 MHz | 15,900 W |
5 MHz | 6,928 W |
10 MHz | 4,802 W |
50 MHz | 1,992 W |
100 MHz | 1,344 W |
200 MHz | 900 W |
400 MHz | 602 W |
700 MHz | 438 W |
900 MHz | 382 W |
1,000 MHz | 361 W |
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|---|---|---|---|
1.4 Ohm/1000ft | 1.5 Ohm/1000ft (4.9 Ohm/km) | 26.0 pF/ft (85.3 pF/m) | 50 Ohm | 78% |
UL Voltage Rating | Voltage Rating |
---|---|
300 V (CMP) | 600 V |
Mechanical Characteristics
UL Temperature | Operating |
---|---|
150°C | -25°C to +150°C |
Installation Min. |
---|
6.0 in (150 mm) |
Max. Pull Tension: | 255 lbs (116 kg) |
Bulk Cable Weight: | 137 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor – Plenum, Indoor |
Sustainability: | CA Prop 65 |
Flammability / Reaction to Fire: | NFPA 262 |
CPR Compliance: | CPR Euroclass: Eca |
NEC / UL Compliance: | CL2P, CMP |
CEC / C(UL) Compliance: | CMP |
IEEE Compliance: | IEEE 802.3 10Base5 |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance: | UKCA Mark |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Other Standard Compliance(s): | DEC Part No. 17-00324-00 |
Non-Plenum Number: | 9880 |
Product Notes
Notes: | Ring-band stripes every 2.5 meters to aid users in tap placement. |
History
Update and Revision: | Revision Number: 0.497 Revision Date: 11-27-2023 |
Part Numbers
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
89880 0031000 | Orange | Reel | 1,000 ft | 612825221364 | C |
89880 0031640 | Orange | Reel | 1,640 ft | 612825221371 | C Z |