Construction Details
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 1 | 22 AWG | 7×30 | TC – Tinned Copper |
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Pair(s) | PP – Polypropylene | 0.0135 in (0.343 mm) | 0.056 in (1.4 mm) | Black and Red |
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7×30) TC |
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 0.035 in (0.89 mm) | 0.185 in |
Overall Cable Diameter (Nominal): | 0.185 in. |
Electrical Characteristics
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
---|---|---|---|
17.8 Ohm/1000ft | 25.0 pF/ft (82.0 pF/m) | 45.0 pF/ft (148 pF/m) | 3 Amps per Conductor at 25ºC |
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
UL Temperature | Operating |
---|---|
75°C | -20°C to 75°C |
Stationary Min. | Installation Min. |
---|---|
1.85 in (47.0 mm) | 1.85 in |
Max. Pull Tension: | 27 lbs (12 kg) |
Bulk Cable Weight: | 17 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor |
Flammability / Reaction to Fire: | UL 1685 FT4 Loading |
NEC / UL Compliance: | Article 800, CMG |
AWM Compliance: | AWM 21307 |
CEC / C(UL) Compliance: | CMG |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
History
Update and Revision: | Revision Number: 0.282 Revision Date: 02-15-2024 |
Part Numbers
Item # | Color | UPC |
---|---|---|
9462ZH 0101000 | Black | 612825382294 |
9462ZH 010500 | Black | 612825382300 |