Features & Benefits
- Reliable network performance: Designed for mission-critical situations that require constant uptime, whether indoor or outside
- Best-in-class system noise immunity: Achieved through outstanding cable balance, is less susceptible to RFI/EMI in noisy environments
- Reduce installation time and costs: 10GXW is the smallest and lightest horizontal Category 6A cable available
- Unparalleled performance: Full 100m channel length under 100W PoE load without derating up to 60°C using 10GXS cables
- Designed to Last: Higher pulling tensions and tighter bend radii offered by Bonded-Pair Cables
Specifications
Product Overview
Suitable Applications |
harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force,, lower temperature |
---|---|
Patent |
This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
Construction Details
Conductor
Element | Size | Stranding | Material | No. of Elements |
---|---|---|---|---|
Pair(s) | 24 AWG | Solid | BC – Bare Copper | 4 |
Insulation
Material | Color Code |
---|---|
PO – Polyolefin | White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown |
Bonded-Pair |
Yes |
---|
Inner Jacket
Material | Nom. Diameter | Ripcord |
---|---|---|
PVC – Polyvinyl Chloride | 0.2 in (5.1 mm) | Yes |
Armor
Armor Type & Material | Armor Thickness | Diameter Over Armor |
---|---|---|
AIA – Aluminum Interlock Armor | 0.025 in (0.64 mm) | 0.463 in (11.8 mm) |
Outer Jacket
Separator | Material | Nom. Diameter |
---|---|---|
Polyester Tape | PVC – Polyvinyl Chloride | 0.553 in (14.0 mm) |
Overall Cable Diameter (Nominal) |
0.553 in (14.0 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|---|
9 Ohm/1000ft | 160 pF/100m |
Delay
Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|---|---|
510 ns/100m | 25 ns/100m | 70% |
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2 dB/100m | 65.3 | 65.3 | 63.3 | 63.3 | 63.8 | 60.8 | 20 | 100 ± 12 | 105 ± 10 Ohm |
4 | 4 dB/100m | 56.3 | 56.3 | 52.3 | 52.3 | 51.7 | 48.7 | 23 | 100 ± 12 | 100 ± 10 |
8 | 5.7 dB/100m | 51.8 | 51.8 | 46.1 | 46.1 | 45.7 | 42.7 | 24.5 | 100 ± 12 | 100 ± 10 |
10 | 6.4 dB/100m | 50.3 | 50.3 | 43.9 | 43.9 | 43.8 | 40.8 | 25 | 100 ± 12 | 100 ± 10 |
16
Resources |
DataTuff Fiber Optic Renewable Grade Cable
Copper Catalog
Blade Slot Selection Table