Features & Benefits
- Reliable network performance: Designed for mission-critical situations that require constant uptime, whether indoor or outside
- Best-in-class system noise immunity: Achieved through outstanding cable balance, is less susceptible to RFI/EMI in noisy environments
- Reduce installation time and costs: 10GXW is the smallest and lightest horizontal Category 6A cable available
- Unparalleled performance: Full 100m channel length under 100W PoE load without derating up to 60°C using 10GXS cables
- Designed to Last: Higher pulling tensions and tighter bend radii offered by Bonded-Pair Cables
Specifications
Product Overview
Suitable Applications |
OSP-Outdoor, Indoor/Outdoor, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, Noisy Environments, HDBaseT |
---|---|
Patent |
This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
Construction Details
Conductor
Size | Stranding | Material | No. of Pairs |
---|---|---|---|
23 AWG | Solid | BC – Bare Copper | 4 |
Insulation
Material | Color Code |
---|---|
PO – Polyolefin | White & Blue, White & Orange, White & Green, White & Brown |
Inner Jacket
Separator | Material | Nom. Diameter |
---|---|---|
Center Member (Patented X-Spline®) | PE – Polyethylene | 0.270 in (6.86 mm) |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 26 AWG (7×34) TC |
Waterblocking |
Gel Filled |
---|
Outer Jacket
Material | Material Trade Name | Nom. Diameter | Ripcord |
---|---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | Haloarrest® | 0.370 in (9.40 mm) | Yes |
Overall Cable Diameter (Nominal) |
0.370 in (9.40 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|---|
82 Ohm/km (25 Ohm/1000ft) | 45 pF/100m |
Delay
Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|---|---|---|
100 MHz | 537.6 ns/100m | 45 ns/100m | 64% |
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. PSNEXT [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] | Min. PSANEXT [dB] | Min. PSAACRF [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 2.1 dB/100m | 72.3 | 70.2 | 67.8 | 64.8 | 20.0 | 105 +/- 10 | 115 +/- 15 | 67.0 | 67.0 | 40.0 | 35.0 |
4 | 3.8 dB/100m | 63.3 | 59.5 | 55.8 | 52.8 | 23.0 | 105 +/- 10 | 100 +/- 7 | 67.0 | 66.2 | 40.0 | 23.0 |
8 | 5.3 dB/100m | 58.8 | 53.4 | 49.7 | 46.7 | 24.5 | 100 +/- 22 | 100 +/- 7 | 67.0 | 60.1 | 40.0 | 16.9 |
Part Numbers
|
DataTuff Fiber Optic Renewable Grade Cable
Copper Catalog
Blade Slot Selection Table