Features & Benefits
- Improve Crosstalk Performance: Central spline separates pairs and maintains stable pair position
- Optimized Cable Balance: Improved balance of transmission performance for simultaneous parallel transmission protocols
- Performance Reliability: Guarantees across all parameters, including insertion loss and crosstalk, for excellent uptime, headroom and network speeds
- Withstand Installation Rigors: Bonded-Pair Cables handle higher pulling tensions and tighter bend radii
- Easy, Mess-free Outdoor Installations: Dry Core Outside Plant and Indoor/Outdoor Plenum cables contain no inconvenient water-blocking gels, tapes, or powders
Specifications
Product Overview
Suitable Applications |
OSP-Outdoor, Indoor/Outdoor, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Noisy Environments, Not Suitable for Marine Application |
---|---|
Patent |
This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
Construction Details
Conductor
Size | Stranding | Material | No. of Pairs |
---|---|---|---|
23 AWG | Solid | BC – Bare Copper | 4 |
Insulation
Material | Color Code |
---|---|
PO – Polyolefin | White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown |
Waterblocking |
Gel Filled |
---|
Outer Jacket
Separator | Material | Material Trade Name | Nom. Diameter |
---|---|---|---|
Center Member (Patented X-Spline®) | LSZH – Low Smoke Zero Halogen (Flame Retardant) | Haloarrest® | 0.275 in (6.99 mm) |
Overall Cable Diameter (Nominal) |
0.275 in (6.99 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|---|
93.8 Ohm/km (28.6 Ohm/1000ft) | 160 pF/100m |
Delay
Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|---|---|---|
100 MHz | 537.6 ns/100m | 45 ns/100m | 65% |
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 2.0 dB/100m | 74.3 | 72.3 | 70.3 | 67.8 | 64.8 | 20.0 | 100 ± 15 | 100 ± 15 | 40.0 | 35.0 |
4 | 3.8 dB/100m | 65.3 | 63.3 | 59.5 | 55.7 | 52.7 | 23.0 | 100 ± 15 | 100 ± 15 | 40.0 | 23.0 |
8 | 5.3 dB/100m | 60.8 | 58.8 | 53.4 | 49.7 | 46.7 | 24.5 | 100 ± 15 | 100 ± 15 | 40.0 | 16.9 |
10 | 6.0 dB/100m | 59.3 | 57.3 | 51.4 | 47.8 | 44.8 | 25.0 | 100 ± 15 | 100 ± 15 | 40.0 | 15.0 |
16 | 7.6 dB/100m | 56.3 | 54.3 | 46.7 | 43.7 | 40.7 | 25.0 | 100 ± 15 | 100 ± 15 | 38.0 | 10.9 |
20 | 8.5 dB/100m | 54.8 |
Part Numbers
|