, , ,

Category 3 Backbone Cable, 100 Pair, U/UTP, CMP (Category 3 Cable) – Belden (DPLN100)


Category 3 Premise Backbone Cable (16MHz), DIW 100 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP, PVC-LS Jacket
Belden’s DataTwist 3 products come in a variety of pair counts ranging from 2 to 400 in riser and plenum. ATMM (corrugated aluminum tape) versions are also available for added crush resistance.

Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Features & Benefits

  • Rugged Design: Cables meet and exceed ANSI/TIA-568-C.2 and CSA T529-95 specifications
  • Engineered to Perform: High-value UTP cable engineered to perform to Category 3 requirements per ANSI/TIA-568-C.2

Specifications

Product Overview

Suitable Applications

Premise Backbone Cable, Ethernet 10BASE-T, Analog Phone, FAX

Construction Details

Conductor

Size Stranding Material No. of Pairs
24 AWG Solid BC – Bare Copper 100

Insulation

Material Color Code
PVC – Polyvinyl Chloride Western Electric (Non-Striped) Bound in 25 Pair Sub-Units, Binder 1: Blue/White, Binder 2: Orange/White, Binder 3: Green/White, Binder 4: Brown/White

Outer Jacket

Material Material Trade Name Nom. Diameter Ripcord
PVC – Polyvinyl Chloride Flamarrest® 0.775 in (19.7 mm) Yes

Electrical Characteristics

Electricals

Max. Conductor DCR Max. Capacitance Unbalance
93.8 Ohm/km (28.6 Ohm/1000ft) 330 pF/100m

Delay

Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
16 MHz 543 ns/100m 45 ns/100m 61%

High Frequency

Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. RL (Return Loss) [dB] Max./Min. Fitted Impedance [Ohm]
0.772 2.2 dB/100m 47.0 43.0 50.1 46.1
1 2.6 dB/100m 45.0 41.0 47.8 43.8 12.0 100 ± 15
4 5.6 dB/100m 36.0 32.0 36.0 32.0 12.0 100 ± 15
8 8.5 dB/100m 31.0 28.0 28.3 24.3 12.0 100 ± 15
10 9.7 dB/100m 30.0 26.0 26.2 22.3 12.0 100 ± 15
16 13.1 dB/100m 27.0 23.0 20.1 16.1 10.0 100 ± 15

Voltage

UL Voltage Rating
300 V (CMP)

Mechanical Characteristics

Temperature

UL Temperature Operating Installation Storage
60°C -30°C To +60°C 0°C To +50°C -30°C To +60°C

Bend Radius

Stationary Min. Installation Min.
7.75 in (197 mm) 15.5 in (394 mm)

Max. Pull Tension

Part Numbers

Item # Color Putup Type Length UPC
DPLN100 732CUT Olive Cut to Length 612825061014
DPLN100 732CUT Olive Cut to Length 1 ft 612825061014

Systems to Support Key Applications
Blade Slot Selection Table

SKU: BELDEN-DPLN100 Categories: , , ,

Brand

Belden

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)