Features & Benefits
- Reliable network performance: Designed for mission-critical situations that require constant uptime, whether indoor or outside
- Best-in-class system noise immunity: Achieved through outstanding cable balance, is less susceptible to RFI/EMI in noisy environments
- Reduce installation time and costs: 10GXW is the smallest and lightest horizontal Category 6A cable available
- Unparalleled performance: Full 100m channel length under 100W PoE load without derating up to 60°C using 10GXS cables
- Designed to Last: Higher pulling tensions and tighter bend radii offered by Bonded-Pair Cables
Specifications
Product Overview
Suitable Applications |
High Flex, Automation, Robotics, exposure to oil and gasoline, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. |
---|
Construction Details
Conductor
Element | Size | Stranding | Material | No. of Pairs |
---|---|---|---|---|
Pair(s) | 26 AWG | 7×34 | TC – Tinned Copper | 4 |
Insulation
Element | Material | Nom. Insulation Diameter | Color Code |
---|---|---|---|
Pair(s) | PE – Polyethylene | 0.068 in (1.7 mm) | Blue & White/Blue, Orange & White/Orange, Green & White/Green, Brown & White/Brown |
Outer Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Braid | Tinned Copper (TC) | 75% |
Outer Jacket
Material | Nom. Diameter |
---|---|
TPE – Thermoplastic Elastomer | 0.29 in (7.4 mm) |
Overall Cable Diameter (Nominal) |
0.29 in (7.4 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR |
---|
44.4 Ohm/1000ft |
Delay
Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|---|---|
540 ns/100m | 45 ns/100m | 67% |
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] | Min. TCL [dB] | Min. ELTCTL [dB] | Max. Surface Transfer Impedance [mOhm/m] | Min. Coupling Attenuation [dB] |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3.1 dB/100m | 74.3 | 72.3 | 67.8 | 64.8 | 20.0 | 100 ± 15 | 100 +/- 10 | 40.0 | 35.0 | 50.0 | |
4 | 5.7 dB/100m | 65.3 | 63.3 | 55.8 | 52.8 | 23.0 | 100 ± 15 | 100 ± 15 | 40.0 | 23.0 | 75.9 | |
8 | 8.0 dB/100m | 60.8 | 58.8 | 49.7 | 46.7 | 24.5 | 100 ± 15 | 100 ± 15 | 40.0 | 16.9 | 93.5 | |
10 | 8.9 dB/100m | 59.3 | 57.3 | 47.8 | 44.8 | 25.0 | 100 ± 15 | 100 ± 15 | 40.0 | 15.0 | 100.0 | |
16 | 11.2 dB/100m | 56.2 | 54.2 | 43.7 | 40.7 | 25.0 | 100 ± 15 | 100 ± 15 |
DataTuff Fiber Optic Renewable Grade Cable
Copper Catalog