Fiber indoor/outdoor cable, TeraSPEED®, Single Jacket/Single Armor, 120 min Fire Survival, LSZH, Gel-Filled, Stranded Loose Tube, Singlemode G.652.D and G.657.A1, Meters jacket marking, Black jacket color. Provides Rodent Resistance 760245385 | C-096-LA-8W-M12BK/25G/GY/FS – CommScope


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Specifications

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable
Product Series C-LA

General Specifications

Armor Type Corrugated steel
Cable Type Stranded loose tube
Construction Type Armored
Subunit Type Gel-filled
Jacket Color Black
Jacket Marking Meters
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB  F.O. CABLE 760245385 INT/EXT FIRE SURVIVAL 96 X 9/125 OS2 (Serial NUMBER) (METRE MARK)
Subunit, quantity 8
Fibers per Subunit, quantity 12
Total Fiber Count 96

Dimensions

Buffer Tube/Subunit Diameter 2.5 mm | 0.098 in
Diameter Over Jacket 16 mm | 0.630 in

Representative Image

Click on image to enlarge.


Mechanical Specifications

Minimum Bend Radius, loaded 330 mm | 12.992 in
Minimum Bend Radius, unloaded 200 mm | 7.874 in
Tensile Load, long term, maximum 2000 N | 449.618 lbf
Tensile Load, short term, maximum 4000 N | 899.236 lbf
Compression 40 N/mm | 228.406 lb/in
Compression Test Method IEC 60794-1 E3
Impact 5 N-m | 44.254 in lb
Impact Test Method IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method IEC 60794-1 E1
Twist 5 cycles
Twist Test Method IEC 60794-1 E7

Optical Specifications

Fiber Type G.652.D and G.657.A1, TeraSPEED® | OS2

Environmental Specifications

Operating Temperature
-30 °C to +70 °C (-22 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Cable Qualification Standards EN 187105 | IEC 60794-1-2
EN50575 CPR Cable EuroClass Fire Performance Cca
EN50575 CPR Cable EuroClass Smoke Rating s2
EN50575 CPR Cable EuroClass Droplets Rating d0
EN50575 CPR Cable EuroClass Acidity Rating a1
Environmental Space
Building Information Modeling (BIM) Objects

Revit BIM Models

Declaration of Performance

Declaration of Performance P03401AMA

Product Compliance Documentation

Global Trade Data

Statement of Compliance RoHS/REACH

Product Specification

760245385 Product specifications

760245385 Product specifications (Comprehensive)

Warranty

CommScope Limited Product Warranty

Building Information Modeling (BIM) Objects

Revit BIM Models

Declaration of Performance

Declaration of Performance P03401AMA

Product Compliance Documentation

Global Trade Data

Statement of Compliance RoHS/REACH

Product Specification

760245385 Product specifications

760245385 Product specifications (Comprehensive)

Warranty

CommScope Limited Product Warranty

SKU: 760245385-C-096-LA-8W-M12BK/25G/GY/FS Categories: , , ,