Product Overview
Suitable Applications: | Standard analog video |
Construction Details
RG Type: | 59 |
No. of Elements | Size | Stranding | Nom. Diameter | Material |
---|---|---|---|---|
1 | 23 AWG | Solid | 0.58 mm | BC – Bare Copper |
Element | Material | Nom. Insulation Diameter |
---|---|---|
Insulated Conductor | PE – Polyethylene (Foam) | 3.7 mm (0.15 in) |
Layer | Outer Shield Type | Material | Coverage |
---|---|---|---|
1 | Braid | Tinned Copper (TC) | 92% |
2 | Braid | Tinned Copper (TC) | 92% |
Material | Nom. Diameter |
---|---|
PVC – Polyvinyl Chloride | 6 mm |
Table Notes: | According to European Standard EN 50290-2-20 |
Electrical Characteristics
Regularity of Impedance: | Min. 40 dB |
Frequency | Min. Return Loss |
---|---|
5 – 30 MHz | 20 dB |
30 – 470 MHz | 20 dB |
470 – 862 MHz | 18 dB |
Table Notes: | In each frequency band, 3 peak values up to 4 dB lower are allowed |
Frequency | Nom. Attenuation |
---|---|
5 MHz | 2.4 dB/100m |
50 MHz | 8 dB/100m |
100 MHz | 11.6 dB/100m |
230 MHz | 18.3 dB/100m |
300 MHz | 21.2 dB/100m |
400 MHz | 25 dB/100m |
470 MHz | 27.5 dB/100m |
860 MHz | 39.2 dB/100m |
Table Notes: | Max. attenuation 10% higher |
Max. Conductor DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|---|---|---|
40 Ohm/km (12 Ohm/1000ft) | 67 pF/m (20 pF/ft) | 75 Ohm | 66% |
Mechanical Characteristics
Operating | Installation | Storage |
---|---|---|
-15°C To +70°C | -5°C To +50°C | -15°C To +70°C |
Stationary Min. |
---|
30 mm (1.2 in) |
Bulk Cable Weight: | 58 kg/km |
Standards and Compliance
Environmental Suitability: | Indoor/Outdoor – Euroclass Eca |
Flammability / Reaction to Fire: | IEC 60332-1-2 |
CPR Compliance: | CPR Euroclass: Eca |
ISO/IEC Compliance: | IEC 61196 |
CENELEC Compliance: | EN 50117-1 |
European Directive Compliance: | EU CE Mark |
UK Regulation Compliance: | UKCA Mark |
History
Update and Revision: | Revision Number: 0.195 Revision Date: 12-19-2022 |