MA6AUFLD – MarineTuff Cat 6A Duplex, U/FTP, 2x4Pr 23 BC, FMPE Ins, LSZH, Indoor, LR certified


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Shipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc.

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
23 Solid BC – Bare Copper 8
Conductor Count: 16
Total Number of Pairs: 8
Insulation
Material Nominal Diameter
PO – Polyolefin (Foam) 1.35 mm
Color Chart
Number Color
Pair 1 White & Blue
Pair 2 White & Orange
Pair 3 White & Green
Pair 4 White & Brown
Inner Shield
Type Material
Tape Bi-Laminate (Alum+Poly)
Outer Shield
Drainwire Material Drainwire AWG
Tinned Copper 28 AWG
Outer Jacket
Material Nominal Diameter Diameter +/- Tolerance
LSZH – Low Smoke Zero Halogen (SHF1) 7.5 mm 0.3 mm

Construction and Dimensions

Min Elongation at Breakof Jacket: 125 %
Min Tensile Strength of Jacket: 9 MPa
Min Tensile Strength of Jacket Aged: 30 %
Min Elongation at Break of Jacket Aged: 30 %

Electrical Characteristics

Conductor DCR
Max. Conductor DCR Max DCR Unbalanced Between Pairs [%] Max. DCR Unbalanced Within Pair [%]
95 Ohm/km 4 % 2 %
Capacitance
Max. Capacitance Unbalance Max. Mutual Capacitance
160 pF/100m 56 pF/m
Insulation Resistance: 5000 MOhm.m
Impedance
Nominal Characteristic Impedance
100 Ohm
Delay
Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
45 ns/100m 77%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. PSANEXT Min. PSAACRF Min. TCL [dB] Min. ELTCTL [dB]
1 MHz 2.1 dB/100m 75.3 dB 72.3 dB 73.2 dB 70.2 dB 68 dB 65 dB 20 dB 67 dB 67 dB 40 dB 35 dB
4 MHz 3.8 dB/100m 66.3 dB 63.3 dB 62.5 dB 59.5 dB 56 dB 53 dB 23 dB 67 dB 66.2 dB 34 dB 23 dB
10 MHz 5.9 dB/100m 60.3 dB 57.3 dB 54.4 dB 51.4 dB 48 dB 45 dB 25 dB 67 dB 58.2 dB 30 dB 15 dB
16 MHz 7.5 dB/100m 57.2 dB 54.2 dB 49.7 dB 46.7 dB 43.9 dB 40.9 dB 25 dB 67 dB 54.1 dB 28 dB 10.9 dB
31.3 MHz 10.5 dB/100m 52.9 dB 49.9 dB 42.4 dB 39.4 dB 38.1 dB 35.1 dB 23.6 dB 67 dB 48.3 dB 25.1 dB 5.1 dB
62.5 MHz 15.0 dB/100m 48.4 dB 45.4 dB 33.4 dB 30.4 dB 32.1 dB 29.1 dB 21.5 dB 65.6 dB 42.3 dB 22 dB
100 MHz 19.1 dB/100m 45.3 dB 42.3 dB 26.2 dB 23.2 dB 28 dB 25 dB 20.1 dB 62.5 dB 38.2 dB 20 dB
125 MHz 21.5 dB/100m 43.8 dB 40.8 dB 22.3 dB 19.3 dB 26.1 dB 23.1 dB 19.4 dB 61 dB 36.3 dB 19 dB
200 MHz 27.6 dB/100m 40.8 dB 37.8 dB 13.2 dB 10.2 dB 22 dB 19 dB 18 dB 58 dB 32.2 dB 17 dB
250 MHz 31.1 dB/100m 39.3 dB 36.3 dB 8.2 dB 5.2 dB 20 dB 17 dB 17.3 dB 56.5 dB 30.2 dB 16 dB
350 MHz 34.3 dB/100m 37.1 dB 34.1 dB 17.1 dB 14.1 dB 17.3 dB 54.3 dB 27.3 dB
500 MHz 45.3 dB/100m 34.8 dB 31.8 dB 14 dB 11 dB 17.3 dB 52 dB 24.2 dB
Table Notes: Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009)
Coupling Attenuation Class: Type Ib
Transfer Impedance Class: Grade 2
Voltage
Voltage Rating [V]
72 V DC

Temperature Range

Installation Temperature Range: -5°C To +80°C
Operating Temperature Range: -40°C To +80°C

Mechanical Characteristics

Bending Test: Low temperature bending test -40 °C : No cracks
Pressure Test for Jacket: Test at high temperature IEC 60811-508 80±2 °C 4h : ? 50 %
Heat Stroke Test: Heat Shock test at (150±3°C ,1h) : No cracks
Bulk Cable Weight: 115 kg/km
Min. Bend Radius During Installation: 10*D

Standards

ISO/IEC Compliance: ISO/IEC 11801-2, IEC 60092-360
CENELEC Compliance: EN 50173-1
Data Category: Category 6A
ANSI Compliance: ANSI/TIA 568.2-D (2018)
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4

Applicable Environmental and Other Programs

Environmental Space: Indoor

Suitability

Suitability – Indoor: Yes

Flammability, LS0H, Toxicity Testing

IEC Flammability: IEC 60332-1-2, IEC 60332-3-22
Fluorine Content Test IEC60684-2: HF ? 0.1%
IEC 60754-1 – Halogen Amount: HCL+HBr ? 0.5%
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 10 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
IEC 61034-2 – Smoke Density Min. Transmittance: 60%

Related Part Numbers

Footnote: *Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length.

Product Notes

Notes: LR (Lloyd’s Register) certification

History

Update and Revision: Revision Number: 0.50 Revision Date: 12-12-2023

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)