MA7SFL – MarineTuff Cat 7, S/FTP, 4 Pr 23 BC, FMPE Ins, LSZH, Indoor, LR certified


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Shipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc.

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
23 Solid BC – Bare Copper 4
Conductor Count: 8
Total Number of Pairs: 4
Insulation
Material Nominal Diameter
PO – Polyolefin (Foam) 1.35 mm
Color Chart
Number Color
Pair 1 White & Blue
Pair 2 White & Orange
Pair 3 White & Green
Pair 4 White & Brown
Inner Shield
Element Type Material Coverage [%]
Individual Shielded Pair Tape Bi-Laminate (Alum+Poly) 100%
Outer Shield
Type Material Coverage [%] Drainwire Material Drainwire AWG
Braid Tinned Copper (TC) 30% Tinned Copper 28 AWG
Outer Jacket
Material Nominal Diameter Diameter +/- Tolerance
LSZH – Low Smoke Zero Halogen (SHF1) 7.8 mm 0.3 mm

Construction and Dimensions

Min Elongation at Breakof Jacket: 125 %
Min Tensile Strength of Jacket: 9 MPa
Min Tensile Strength of Jacket Aged: 30 %
Min Elongation at Break of Jacket Aged: 30 %

Electrical Characteristics

Conductor DCR
Max. Conductor DCR Max DCR Unbalanced Between Pairs [%] Max. DCR Unbalanced Within Pair [%]
95 Ohm/km 4 % 2 %
Capacitance
Max. Capacitance Unbalance Max. Mutual Capacitance
160 pF/100m 56 pF/m
Insulation Resistance: 5000 MOhm.m
Impedance
Nominal Characteristic Impedance
100 Ohm
Delay
Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
25 ns/100m 78%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 MHz 2.1 dB/100m 78 dB 75 dB 75.9 dB 72.9 dB 78 dB 75 dB 20 dB 40 dB 35 dB
4 MHz 3.7 dB/100m 78 dB 75 dB 74.3 dB 71.3 dB 78 dB 75 dB 23 dB 34 dB 23 dB
10 MHz 5.8 dB/100m 78 dB 75 dB 72.2 dB 69.2 dB 74 dB 71 dB 25 dB 30 dB 15 dB
16 MHz 7.3 dB/100m 78 dB 75 dB 70.7 dB 67.7 dB 69.9 dB 66.9 dB 25 dB 28 dB 10.9 dB
31.3 MHz 10.3 dB/100m 78 dB 75 dB 67.7 dB 64.7 dB 64.1 dB 61.1 dB 23.6 dB 25.1 dB 5.1 dB
62.5 MHz 14.6 dB/100m 75.5 dB 72.5 dB 60.9 dB 57.9 dB 58.1 dB 55.1 dB 21.5 dB 22 dB
100 MHz 18.5 dB/100m 72.4 dB 69.4 dB 53.9 dB 50.9 dB 54 dB 51 dB 20.1 dB 20 dB
125 MHz 20.8 dB/100m 70.9 dB 67.9 dB 50.2 dB 47.2 dB 52.1 dB 49.1 dB 19.4 dB 19 dB
200 MHz 26.5 dB/100m 67.9 dB 64.9 dB 41.4 dB 38.4 dB 48 dB 45 dB 18 dB 17 dB
250 MHz 29.7 dB/100m 66.4 dB 63.4 dB 36.7 dB 33.7 dB 46 dB 43 dB 17.3 dB 16 dB
300 MHz 32.7 dB/100m 65.2 dB 62.2 dB 32.6 dB 29.6 dB 44.5 dB 41.5 dB 17.3 dB
500 MHz 42.8 dB/100m 61.9 dB 58.9 dB 19.2 dB 16.2 dB 40 dB 37 dB 17.3 dB
600 MHz 47.1 dB/100m 60.7 dB 57.7 dB 13.6 dB 10.6 dB 38.4 dB 35.4 dB 17.3 dB
Table Notes: Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009)
Coupling Attenuation Class: Type Ib
Transfer Impedance Class: Grade 2
Voltage
Voltage Rating [V]
72 V DC

Temperature Range

Installation Temperature Range: -5°C To +80°C
Operating Temperature Range: -40°C To +80°C

Mechanical Characteristics

Bending Test: Low temperature bending test -40 °C : No cracks
Pressure Test for Jacket: Test at high temperature IEC 60811-508 80±2 °C 4h : ? 50 %
Heat Stroke Test: Heat Shock test at (150±3°C ,1h) : No cracks
Bulk Cable Weight: 65.5 kg/km
Min. Bend Radius During Installation: 10*D

Standards

ISO/IEC Compliance: ISO/IEC 11801-2, IEC 60092-360
CENELEC Compliance: EN 50173-1
Data Category: Category 7
ANSI Compliance: ANSI/TIA 568.2-D (2018)
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4

Applicable Environmental and Other Programs

Environmental Space: Indoor

Suitability

Suitability – Indoor: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1581 VW-1
IEC Flammability: IEC 60332-1-2, IEC 60332-3-22
Fluorine Content Test IEC60684-2: HF ? 0.1%
IEC 60754-1 – Halogen Amount: HCL+HBr ? 0.5%
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 10 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
IEC 61034-2 – Smoke Density Min. Transmittance: 60%

Related Part Numbers

Footnote: *Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length.

Product Notes

Notes: LR (Lloyd’s Register) certification

History

Update and Revision: Revision Number: 0.54 Revision Date: 12-12-2023