Product description
Type: | MTS2748-6X-MP-E |
Name: | MTS2748-6X-MP-E |
Description: | 1U rack mount, 48 × FE/GE POE/POE+, 4 × 1/10G SFP+ slots, redundant PSU, enhanced software |
Part Number: | 942999831 |
Port type and quantity: | 48 × FE/GE POE/POE+, 4 × 1/10G SFP+ slots, 1 × RJ45 Console port, 1 × USB 2.0, no Reset Button, extendible with one extended slot for media module with 2 × 1/10G SFP+ interfaces |
Heat Radiation Type: | Fixed fan |
More Interfaces
Power Supply: | 2 × modular redundant PSUs, hot swappable |
Power requirements
PoE Budget: | According to the PSU module used: 380W (if apply 1 × PSU500); 760W (if apply 2 × PSU500); 760W (if apply 1 × PSU880); 1520W (if apply 2 × PSU880); PSU120 has no PoE output power |
Operating Voltage: | 100-240VAC 50-60Hz, redundancy PSU supported |
Applicable PSU modules: | MTM2700-PSU120, MTM2700-PSU500, MTM2700-PSU880 |
Power consumption: | Device non-PoE power consumption:46W, Max. PoE power consumption:1440W |
Ambient conditions
Permissible Humidity (Storage/Transport): | 5% to 95% |
Operating temperature: | -10-+55 °C |
Storage/transport temperature: | -40-+70 °C |
Relative humidity (non-condensing): | 10-90 % |
Mechanical construction
Width: | 442 mm |
Height: | 44.2 mm |
Depth: | 420 mm |
Weight: | 7.8 kg |
Mounting: | Rack mount |
Data link layer protocol and technology | LAN | MAC address learning amount limit; static Mac configuration; black hole MAC |
Dynamic and static ARP; proxy ARP; free ARP | ||
Ethernet; Ethernet II; VLAN; 802.3x; 802.1p; 802.1Q; 802.3ad | ||
Q-in-Q and flexible Q-in-Q; VLAN mapping | ||
STP/RSTP/MST; GVRP; Super VLAN; PVLAN; Voice VLAN; Monitor link; BPDU TUNNEL; PPPOE+ | ||
Multi to one port mirroring; multi to multiport mirroring; RSPAN | ||
PoE | Function | 802.3af; 802.3at; priority; preemptive function; automatic fault monitoring |
Security | Security features | IPv4/v6 ACL; AAA; 802.1X; RADIUS; TACACS+; SSH; port security; user classification; port isolation; UNI/NNI isolation; DHCP snooping; DAI; ARP check; IP source guard; CPU protection |
Attack protection | URPF; LAND attack; SYN Flood attack; Smurf attack; Ping Flood attack; TearDrop attack; Ping of Death attack | |
Network protocol | Routing protocol | Static router; RIP v1/v2; OSPF; BGP; ISIS; RIPng; OSPFv3; BGP4; ISISv6; ECMP; Network load balancing |
Multicast protocol | IGMP PROXY; IGMP filter; MLD v1/v2; IGMP Snooping; MLD v1/v2 Snooping; PIM-DM; PIM-SM; PIM-SDM; PIM-SSM | |
IP application | DHCP Server; DHCP Client; DHCP Relay; DHCP Snooping; DHCPv6 Server; DHCPv6 Client; DHCPv6 Relay; DNS; Ping; FTP Server; FTP Client; IP Accounting; UDP Helper; NTP | |
IPv6 | IPv6 basic function: IPv6 ND, IPv6 PMTU, IPv6 ACL, DS-Lite, IPv4/v6 Dual Stack | |
IPv6 Tunneling | IPv6 manual tunnel; GRE tunnel; Ipv4/Ipv6 compatible automatic tunnel, 6to4 tunnel, ISATAP tunnel | |
QoS | Traffic classification | Based on port/MAC address/IP address/IP priority/DSCP priority/TCP or UDP port number/ protocol type etc. |
Traffic policing | CAR | |
Congestion management | SP; WRR; SP+WRR | |
Congestion avoidance | RED; WRED | |
Virtualization | Virtualization technology | Stacking, up to 8 devices |
Management | Network management | Console port; HTTP; Telnet; SSH management; SNMP v1/v2/v3; RMON 1/2/3/9; SYSLOG; DDMI |
Line management | VCT; UDLD | |
Traffic analysis | sFlow traffic analysis | |
OAM | SLA | Including network delay/network jitter/packet loss rate test |
Reliability | Link reliability | BFD for OSPF/VRRP etc.; Keepalive Gateway; VRRP/VRRPv6; ERPS(G.8032) ring network protocol |
Data center feature | VXLAN; EVPN; XML API/NETCONF; M-LAG |
Mechanical stability
IEC 60068-2-6 vibration: | 1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min |
IEC 60068-2-27 shock: | 15 g, 11 ms duration, 18 shocks |
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD): | 4 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 electromagnetic field: | 10V/m (80-1000MHz), 3V/m (1000-6000MHz) |
EN 61000-4-4 fast transients (burst): | 2 kV power line, 1 kV data line |
EN 61000-4-5 surge voltage: | power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
EN 61000-4-6 Conducted Immunity: | 10 V (150 kHz-80 MHz) |
EN 61000-4-8 power freq magnetic field: | 30A/m |
EN 61000-4-11 voltagedips,shortinterrupt: | 0%(20ms), 40%(300ms), 70%(500ms), 0%(5s) |
EMC emitted immunity
EN 55032: | EN 55032 Class A |
EN 61000-3-2: | EN 61000-3-2 Class A |
EN 61000-3-3: | EN 61000-3-3 |
FCC CFR47 Part 15: | FCC 47CFR Part 15, Class A |
Approvals
FCC: | CE/FCC Compliant |
UL/cUL: | Compliant |
China Network Access Certificate: | Compliant |
CCC: | Compliant |
Common Criteria: | EAL 2+ |
RoHS Compliant: | RoHS ((EU) 2015/863) and RoHS (GB/T26572-2011) compliant |
Scope of delivery and accessories
Accessories to Order Separately: | Network Management Industrial HiVision, SFP, extended line card |
Scope of delivery: | Device, console cable, installation package, “*Power cord does not included in the package |
History
Update and Revision: | Revision Number: 0.82 Revision Date: 01-17-2024 |