Product Overview
Suitable Applications: | This Category 5e Cable is a cable standard for Gigabit Ethernet, capable to continue transmitting data even when being directly attacked by fire. |
Construction Details
Size | Stranding | Stranding Class | Material | No. of Pairs | No. of Elements |
---|---|---|---|---|---|
22 AWG | Solid | Class 1 | BC – Bare Copper | 4 | 8 |
Material | Nom. Insulation Diameter | Color Code | Notes |
---|---|---|---|
PE – Polyethylene | 1.23 mm (0.0484 in) | Blue & White with Blue Strips, Orange & White with Orange Strips, Green & White with Green Strips, Brown & White with Brown Strips | Fire Protection Barrier: Mica glass Tape(MGT) |
Notes |
---|
All 4 Pairs laid up together over a cross filler & binded by Foam-PP Tape binder |
Material | Nom. Diameter |
---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 11.2 mm (0.441 in) |
Shield Type | Material | Drainwire Type | Notes |
---|---|---|---|
Tape | Polyester + Bi-Laminate (Alum+Poly) | 26 AWG (Solid) TC | A Fire Protection Barrier: Mica Glass Tape wrapped over shielding |
Armor Type & Material |
---|
SWA – Steel Wire Armor |
Material |
---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
Overall Cable Diameter (Nominal): | 14.80 mm (0.5827 in) |
Electrical Characteristics
Max. Conductor DCR | Nom. Characteristic Impedance |
---|---|
54.3 Ohm/km @ 20 Deg. C | 100 Ohm |
Max. Delay Skew |
---|
45 ns/100m |
536 ns/100m |
Voltage Rating |
---|
60 V |
Mechanical Characteristics
Operating |
---|
-40°C to + 60°C |
Standards and Compliance
Environmental Suitability: | UV Resistance, Oil Resistance |
Flammability / Reaction to Fire: | IEC 60332-1-2, IEC 60332-3-22, IEC 60331-23 |
Data Category: | Category 5e |
ISO/IEC Compliance: | IEC 61034-2 – Smoke Density Min Transmittance = 60% |
European Halogen Free Standards: | IEC 60754-1 – Halogen Amount = 0.5 %, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
Product Notes
Notes: | TIA 568 D .2 Cat.5E and ISO/IEC 11801 class D and IEEE 802.3 100Base TX,1000Base T, Circuit integrity performance during a fire of the relevant requirements of IEC 60331 23. Cable will meet CAT 5e channel requirements up to 80m length or up to 70m permanent length. |
History
Update and Revision: | Revision Number: 0.16 Revision Date: 01-25-2024 |