Product Overview
Suitable Applications: | Industrial Ethernet Cat 6 connection with Fire Resistant capability |
Construction Details
Element | Size | Stranding | Material | No. of Pairs | No. of Elements |
---|---|---|---|---|---|
Conductor(s) | 23 | Solid | BC – Bare Copper | 4 | 8 |
Material | Nom. Insulation Diameter | Color Code | Notes |
---|---|---|---|
PE – Polyethylene | 1.58 mm (0.0622 in) | Blue & White with Blue Strip, Orange & White with Orange Strip, Green & White with Green Strip, Brown & White with Brown Strip | Fire Protection Barrier: Mica glass Tape(MGT), Twist Direction = S, 25% AL-mylar tape(Overlapping) |
Shield Type | Drainwire Type | Notes |
---|---|---|
Tape | 26 AWG (Solid) TC | Fire Protection Barrier: Mica Glass Tape(MGT), Water blocking structure: Water block tape |
Material |
---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
Material | Nom. Diameter |
---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 11.40 mm (0.4488 in) |
Electrical Characteristics
Max. Conductor DCR | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
---|---|---|
73.2 Ohm/km (22.3 Ohm/1000ft) | 330 pF/100m | 100 Ohm |
Max. Delay | Max. Delay Skew |
---|---|
536 ns/100m | 45 ns/100m |
Frequency [MHz] | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] |
---|---|---|---|---|---|---|
1 | 2.03 | 74.3 | 72.3 | 67.8 | 64.8 | 20.0 |
4 | 3.78 | 65.3 | 63.3 | 55.8 | 52.8 | 23.0 |
8 | 5.32 | 60.8 | 58.8 | 49.7 | 46.7 | 24.5 |
10 | 5.95 | 59.3 | 57.3 | 47.8 | 44.8 | 25.0 |
16 | 7.55 | 56.2 | 54.2 | 43.7 | 40.7 | 25.0 |
20 | 8.47 | 54.8 | 52.8 | 41.8 | 38.8 | 25.0 |
25 | 9.51 | 53.3 | 52.8 | 39.8 | 36.8 | 24.32 |
31.25 | 10.67 | 51.9 | 49.9 | 37.9 | 34.9 | 23.64 |
62.5 | 15.38 | 47.4 | 45.4 | 31.9 | 28.9 | 21.54 |
100 | 19.8 | 44.3 | 42.3 | 27.8 | 24.8 | 20.11 |
200 | 28.98 | 39.8 | 37.8 | 21.8 | 18.8 | 18.0 |
250 | 32.85 | 38.3 | 36.3 | 19.8 | 16.8 | 17.32 |
UL Voltage Rating |
---|
60 V |
Mechanical Characteristics
Table Notes: | Temperature range : -40°C To +80°C |
Standards and Compliance
Environmental Suitability: | UV Resistance, Oil Resistance |
Flammability / Reaction to Fire: | IEC 60332-1-2, IEC 60332-3-22, IEC 60331-23, BS EN 50200 PH120 |
TIA/EIA Compliance: | EIA/TIA 568 |
ISO/IEC Compliance: | IEC 61034-2 – Smoke Density Min Transmittance = 60% |
European Halogen Free Standards: | IEC 60754-1 – Halogen Amount = 0.50%, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
Other Standard Compliance(s): | BS EN 50289-4-16 |
History
Update and Revision: | Revision Number: 0.33 Revision Date: 12-12-2023 |