Product Overview
Product Category: | Central Loose Tube |
Suitable Applications: | For Indoor/Outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. |
Fiber Specifications
Fiber Type: | OS2, G.652.D |
Fiber Core Diameter: | 125 µm |
Fiber Diameter: | 250 µm |
Fiber Count: | 24 |
Fiber Color Coding: | TIA-598-D |
Cable Construction
Number of Active Subunits: | 1 |
Fibers Per Subunit: | 24 |
Subunit Waterblocking: | Gel Filled |
Subunit Diameter: | 4.0 mm |
Subunit Color: | Natural |
Armor Specifications
Armor Type and Material: | CST – Corrugated Steel Tape |
Outer Jacket Specifications
Strength Member: | Aramid Yarns |
Jacket Material: | LSZH – Low Smoke Zero Halogen (Flame Retardant) |
Nom. Diameter: | 8.6 mm (0.34 in) |
Color: | Black |
Wavelength | 1310 nm | 1550 nm |
---|---|---|
Max. Attenuation | 0.36 dB/km | 0.22 dB/km |
Mode Field Diameter | 9.2 µm | 10.4 µm |
Mechanical Characteristics
Min. Bend Radius During Installation: | 20 x Cable OD |
Min. Bend Radius During Operation: | 10 x Cable OD |
Max. Tensile Strength During Installation: | 1000 N (220 lbf) |
Max. Tensile Strength During Operation: | 400 N (90 lbf) |
Crush Resistance: | 1000 N/100 mm for short term |
Description | Tested Standard |
---|---|
Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E11 |
Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 |
Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 |
Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 |
Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 |
Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 |
Bulk Cable Weight: | 88 kg/km (59 lbs/1000ft) |
Temperature Range
Operating Temperature Range: | -40°C to +70°C |
Storage Temperature Range: | -40°C to +70°C |
Standards and Compliance
Environmental Suitability: | Indoor/Outdoor, Indoor, Outdoor, Non-Halogenated |
Flammability / Reaction to Fire: | IEC 60332-1 Flammability |
ISO/IEC Compliance: | IEC 60793-1-1 |
European Halogen Free Standards: | IEC 60754-1 – Halogen Amount = ? 5 mg/g, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 , IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
European Directive Compliance: | EU Directive 2011/65/EU (RoHS 2) |
History
Update and Revision: | Revision Number: 0.10 Revision Date: 03-14-2024 |