Product Overview
Suitable Applications: | Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc |
Construction Details
Size | Stranding | Material |
---|---|---|
0.75 mm² | 37×0.16 mm | TC – Tinned Copper |
Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|---|---|---|---|
XLP, XLPO, XLPE | 0.27 mm (0.011 in) | 1.62 mm (0.0638 in) | White#1, White#2, White#3, White#4, White#5, White#6, White#7, White#8, White#9, White#10, White#11, White#12, White#13, White#14 | D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°Cfor 240h : No breakdown |
Table Notes: | D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°Cfor 240h : No breakdown |
Shield Type | Material | Coverage |
---|---|---|
Braid | Tinned Copper (TC) | 80% |
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
XLP, XLPO, XLPE | 0.41 mm (0.016 in) | 4.50 mm (0.177 in) |
Nom. Thickness | Nom. Diameter |
---|---|
0.85 mm (0.033 in) | 15.35 mm (0.6043 in) |
Overall Cable Diameter (Nominal): | 15.35 ± 0.25 mm |
Electrical Characteristics
Max. Conductor DCR |
---|
26.7 Ohm/km (8.14 Ohm/1000ft) |
Breakdown Voltage |
---|
2.5kVac/5min |
Mechanical Characteristics
Operating |
---|
-40°C to +120°C |
Stationary Min. | Installation Min. |
---|---|
154 mm (6.06 in) | 154 mm (6.06 in) |
Bulk Cable Weight: | 304 kg/km (204 lbs/1000ft) |
Standards and Compliance
Flammability / Reaction to Fire: | IEC 60332-1-2, IEC 60332-3-24 |
ISO/IEC Compliance: | IEC 60228 |
CENELEC Compliance: | EN 50306-4 |
European Halogen Free Standards: | IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
Other Standard Compliance(s): | TJ/CL 313 |
Product Notes
Notes: | EMEA PN: RTE7P075P; Table 5 Category MMM, ROHS Compliant |
History
Update and Revision: | Revision Number: 0.36 Revision Date: 11-27-2023 |