Product Overview
Suitable Applications: | For use in non safety critical circopperits; Indoor use only |
Physical Characteristics (Overall)
Stranding | Material | Nominal Diameter | No. of Pairs |
---|---|---|---|
Solid | TC – Tinned Copper | 0.63 mm | 1 |
Conductor Count: | 2 |
Total Number of Pairs: | 1 |
Material | Nominal Diameter | Diameter +/- Tolerance |
---|---|---|
PE – Polyethylene | 1.12 mm | 0.05 mm |
Number | Color |
---|---|
Pair 1 | White & Blue |
Type | Material | Drainwire Material | Drainwire Diameter | Drainwire Position |
---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | TC – Tinned Copper | 0.5 mm | In contact with tape |
Table Notes: | Aluminum outside |
Material | Nominal Diameter | Min. Wall Thickness | Ripcord |
---|---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 5.5 mm | 0.8 mm | Yes |
Table Notes: | Ripcord provided under sheath |
Construction and Dimensions
Min Elongation at Breakof Jacket: | 100 % |
Min Tensile Strength of Jacket: | 10 MPa |
Electrical Characteristics
Max. Conductor DCR |
---|
74.8 Ohm/km |
Max. Capacitance Unbalance |
---|
0.6 pF/m |
Min Insulation Resistance: | 50 MOhm*km |
Temperature Range
Storage Temperature Range: | -40°C to +70°C |
Operating Temperature Range: | -15°C To +55°C |
Mechanical Characteristics
Min. Bend Radius During Installation: | 27.5 mm |
Standards
CPR Euroclass: | Eca |
Applicable Environmental and Other Programs
Environmental Space: | Indoor – Euroclass Eca |
Suitability
Suitability – Sunlight Resistance: | Yes |
Flammability, LS0H, Toxicity Testing
IEC Flammability: | IEC 60332-1-2 |
Other Flammability: | E4156 Part 2 |
Related Part Numbers
Item # | Color | Put-Up Type | Length | EAN |
---|---|---|---|---|
YE00380.02305 | Black | Reel | 305 m | 8719605112101 |
YE00380.00500 | Violet | Reel | 500 m | 8719605112088 |
YE00380.01500 | Violet | Reel | 500 m | 8719605112095 |
History
Update and Revision: | Revision Number: 0.147 Revision Date: 02-15-2024 |