Product Overview
Suitable Applications: | Mini RG59 quad shield coaxial cable used where immuntiy to conducted disturbances is required, but space is limited; Coaxial cable used in cable broadband communication networks designed according European Standard EN 50117-1; Operating frequencies between 5 and 3000 MHz |
Physical Characteristics (Overall)
AWG | Stranding | Material | Nominal Diameter | Diameter +/- Tolerance | No. of Coax |
---|---|---|---|---|---|
23 | Solid | BC – Bare Copper | 0.58 mm | 0.02 mm | 5 |
Conductor Count: | 5 |
Type | Material | Nominal Diameter | Diameter +/- Tolerance |
---|---|---|---|
Dielectric | PE – Polyethylene (Foam) | 2.59 mm | 0.15 mm |
Color |
---|
Violet |
Orange |
Brown |
Black |
Gray |
Type | Layer | Material | Coverage [%] | Min. Overlap | Coverage +/- Tolerance |
---|---|---|---|---|---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | 2 mm | ||
Braid | 2 | Tinned Copper (TC) | 95% | 5% | |
Tape | 3 | Tri-Laminate (Alum+Poly+Alum) | 1 mm | ||
Braid | 4 | Tinned Copper (TC) | 90% | 5% |
Material | Nominal Diameter | Diameter +/- Tolerance |
---|---|---|
PVC – Polyvinyl Chloride | 4.7 mm | 0.23 mm |
Material | Nominal Diameter |
---|---|
PVC – Polyvinyl Chloride | 14.5 mm |
Construction and Dimensions
Description | Filler |
---|---|
5 coax bundled around a filler covered with nonwoven foil | Polypropylene (1x) |
Min Elongation at Breakof Jacket: | 150 % |
Min Tensile Strength of Jacket: | 12.5 MPa |
Electrical Characteristics
Max. Conductor DCR | Max. Conductor Loop | Max. Shield DCR |
---|---|---|
66 Ohm/km | 75 Ohm/1000ft | 6.5 Ohm/km |
Nom. Capacitance | Capacitance Tolerance |
---|---|
53 pF/m | 2 pF/m |
Min Insulation Resistance: | 10000 MOhm*km |
Nominal Characteristic Impedance | Nominal Characteristic Tolerance | Regularity of Impedance |
---|---|---|
75 Ohm | 3 Ohm | Min. 40 dB |
Frequency [MHz] | Nom. Insertion Loss |
---|---|
1 MHz | 1.7 dB/100m |
3.6 MHz | 2.6 dB/100m |
10 MHz | 3.9 dB/100m |
71.5 MHz | 10 dB/100m |
135 MHz | 12.5 dB/100m |
270 MHz | 17.7 dB/100m |
540 MHz | 25.3 dB/100m |
720 MHz | 31.1 dB/100m |
750 MHz | 31.5 dB/100m |
1000 MHz | 34.4 dB/100m |
1500 MHz | 42.7 dB/100m |
2000 MHz | 52 dB/100m |
2250 MHz | 52.5 dB/100m |
3000 MHz | 60.7 dB/100m |
Table Notes: | Max. attenuation 10% higher |
Nominal Delay | Nominal Velocity of Propagation (VP) [%] | Velocity of Propagation Tolerance |
---|---|---|
400 ns/ft | 83% | 2% |
Frequency [MHz] | Min. RL (Return Loss) [dB] |
---|---|
5 – 30 MHz | 23 dB |
30 – 850 MHz | 23 dB |
850 – 3000 MHz | 21 dB |
Table Notes: | In each frequency band, 3 peak values up to 4 dB lower are allowed |
Frequency [MHz] | Min. Screening Attenuation After Flexing |
---|---|
30 – 1000 MHz | 110 dB |
1000 – 2000 MHz | 95 dB |
2000 – 3000 MHz | 85 dB |
Screening Class: | A++ |
Frequency [MHz] | Transfer Impedance |
---|---|
5-30 MHz | Max. 0.9 mOhm/m |
Temperature Range
Installation Temperature Range: | -5°C To +50°C |
Storage Temperature Range: | -40°C To +70°C |
Operating Temperature Range: | -40°C To +70°C |
Mechanical Characteristics
Max. Pull Tension: | 160 N |
Min Bend Radius (W/o Pulling Strength): | 150 mm |
Min Bend Radius (Each Coax): | 47 mm |
Standards
CENELEC Compliance: | EN 50117-1, EN 50117-9-2, EN 50290-2-20 |
RG Type: | Mini 59 |
Applicable Environmental and Other Programs
Environmental Space: | Indoor/Outdoor |
Flammability, LS0H, Toxicity Testing
CSA Flammability: | FT4 |
IEC Flammability: | IEC 60332-3-24 |
Related Part Numbers
Item # | Color | Put-Up Type | Length | EAN |
---|---|---|---|---|
YE03414.00500 | Black | Reel | 500 m | 8719605118424 |
History
Update and Revision: | Revision Number: 0.143 Revision Date: 03-30-2023 |