American Tech Supply Full Catalog
Showing 74473–74496 of 75476 results
-
Discontinued Products
Type 12 Pull Through Wireway 1487 Series – (1487CK) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- Ideal for connecting machines to control panels or power sources.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14 gauge steel with 10 gauge steel flanges.
- Continuous flange around wireway ends, requires cables to be pulled through. (For lay-in style, see 1485 Series.)
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during installation.
- Butt hinged covers are secured with easily operated screw clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
Finish
- Sections and fittings are finished in ANSI 61 gray.
Accessories
SKU: 1487CK -
Discontinued Products
Type 12 Pull Through Wireway 1487 Series – (1487CRE) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- Ideal for connecting machines to control panels or power sources.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14 gauge steel with 10 gauge steel flanges.
- Continuous flange around wireway ends, requires cables to be pulled through. (For lay-in style, see 1485 Series.)
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during installation.
- Butt hinged covers are secured with easily operated screw clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
Finish
- Sections and fittings are finished in ANSI 61 gray.
Accessories
SKU: 1487CRE -
Discontinued Products
Type 12 Pull Through Wireway 1487 Series – (1487CRC) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- Ideal for connecting machines to control panels or power sources.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14 gauge steel with 10 gauge steel flanges.
- Continuous flange around wireway ends, requires cables to be pulled through. (For lay-in style, see 1485 Series.)
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during installation.
- Butt hinged covers are secured with easily operated screw clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
Finish
- Sections and fittings are finished in ANSI 61 gray.
Accessories
SKU: 1487CRC -
Discontinued Products
Type 12 Pull Through Wireway 1487 Series – (1487BS) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- Ideal for connecting machines to control panels or power sources.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14 gauge steel with 10 gauge steel flanges.
- Continuous flange around wireway ends, requires cables to be pulled through. (For lay-in style, see 1485 Series.)
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during installation.
- Butt hinged covers are secured with easily operated screw clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
Finish
- Sections and fittings are finished in ANSI 61 gray.
Accessories
SKU: 1487BS -
Discontinued Products
Type 12 Pull Through Wireway 1487 Series – (1487BH) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- Ideal for connecting machines to control panels or power sources.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14 gauge steel with 10 gauge steel flanges.
- Continuous flange around wireway ends, requires cables to be pulled through. (For lay-in style, see 1485 Series.)
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during installation.
- Butt hinged covers are secured with easily operated screw clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
Finish
- Sections and fittings are finished in ANSI 61 gray.
Accessories
SKU: 1487BH -
Discontinued Products
Type 12 Pull Through Wireway 1487 Series – (1487BK) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- Ideal for connecting machines to control panels or power sources.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14 gauge steel with 10 gauge steel flanges.
- Continuous flange around wireway ends, requires cables to be pulled through. (For lay-in style, see 1485 Series.)
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during installation.
- Butt hinged covers are secured with easily operated screw clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
Finish
- Sections and fittings are finished in ANSI 61 gray.
Accessories
SKU: 1487BK -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485FS9) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485FS9 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485ES9) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485ES9 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485DS9) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485DS9 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485CS9) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485CS9 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485FSM) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485FSM -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485ESM) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485ESM -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485DSM) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485DSM -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485CSM) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485CSM -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485DH) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485DH -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485CH) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485CH -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485DL2) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485DL2 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485CL2) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485CL2 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485DL1) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485DL1 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485CL1) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485CL1 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485DK) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485DK -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485CK) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485CK -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1487CB60) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1487CB60 -
Discontinued Products
Type 12 Lay-In Wireway 1485 Series – (1485BS9) (DISCONTINUED)
Application
- Designed to enclose and protect electrical wiring from dirt, dust, oil and water.
- All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”.
Standards
- UL 870 Type 1 (unless marked¹)
- CSA Type 1 (unless marked¹)
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges.
- Flanges are open at the top to allow cables to lay in when doors open.
- 12” x 6” size has a 12 gauge steel body with a 14-gauge cover.
- Smooth continuously welded seams.
- Interior surfaces are smooth to prevent wire damage during
installation. - Butt hinged cover is secured with easily operated quick release clamps.
- Oil resistant gaskets are permanently secured.
- Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together.
- One gasket kit, complete with hardware is provided with each straight section or fitting.
- Sealing plate is supplied.
- Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number.
Finish
- Sections and components are finished in ANSI 61 gray powder coating.
Notes
- When joining a wireway section or fitting to an enclosure be sure to order a box connector.
- When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary.
- When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction.
- Necessary kits are supplied with each section and fitting – see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section.
Accessories
Typical Straight Section
Flat Sealing Plate
Angle Sealing Plate
Barrier Kit
Swivel Nipple
Flexible Fitting
Adjustable Fitting
Cross Fitting
Cut-Off Fitting (Lay-In)
Cut-Off Fitting (Non Lay-In)
Nipple
45 degree Elbow Top Opening
45 degree Elbow Inside Opening
45 degree Elbow Outside Opening
90 degree Elbow Top Opening
90 degree Elbow Inside Opening
90 degree Elbow Outside Opening
Tee Fitting Top Opening
Tee Fitting Outside and Top Opening
Reducers
Box Connector
12″ Transposition Sections Clockwise & Counter-Clockwise
Drop Hanger
Bracket Hanger
Cover Plate
Junction Box
SKU: 1485BS9