American Tech Supply Full Catalog
Showing 769–792 of 75476 results
-
UPS, UPS, Power Solutions, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Online: Lead Acid – 1500V Power Capcity / 240V /2 Post Mounting / 1 SNMP Card / 1 Bypass Module / 3 External Battery – Great Lakes Data Racks and Cabinets
UPS, UPS, Power Solutions, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Online: Lead Acid – 1500V Power Capcity / 240V /2 Post Mounting / 1 SNMP Card / 1 Bypass Module / 3 External Battery – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-ONLA-150A-240-3BP-1M-1BY-2P -
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Line Interactive Lead Acid – 2200VA Power Capcity / 120V /4 Post Mounting / 1 SNMP Card / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Line Interactive Lead Acid – 2200VA Power Capcity / 120V /4 Post Mounting / 1 SNMP Card / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-LILA-220A-120-2BP-1M-0BY-4P -
UPS, Power Solutions, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Line Interactive Lead Acid – 3000VA – C19+C13 Power Capcity / 240V /2 Post Mounting / 1 Bypass Module / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
UPS, Power Solutions, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Line Interactive Lead Acid – 3000VA – C19+C13 Power Capcity / 240V /2 Post Mounting / 1 Bypass Module / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-LILA-300A-240-2BP-0M-1BY-2P -
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Line Interactive Lead Acid – 3000VA – C19+C13 Power Capcity / 240V /2 Post Mounting / 1 SNMP Card / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Line Interactive Lead Acid – 3000VA – C19+C13 Power Capcity / 240V /2 Post Mounting / 1 SNMP Card / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-LILA-300A-240-2BP-1M-0BY-2P -
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Line Interactive Lead Acid – 2200VA Power Capcity / 120V /2 Post Mounting / 1 Bypass Module / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Line Interactive Lead Acid – 2200VA Power Capcity / 120V /2 Post Mounting / 1 Bypass Module / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-LILA-220A-120-2BP-0M-1BY-2P -
Discontinued Products
Type 4X Stainless Steel Freestanding Enclosure 1418 N4 FS QT SS Series – (1418N4SSW18QT) (DISCONTINUED)
Discontinued ProductsType 4X Stainless Steel Freestanding Enclosure 1418 N4 FS QT SS Series – (1418N4SSW18QT) (DISCONTINUED)
Application
- Designed to house electrical, electronic, hydraulic or pneumatic controls with provision for panel mounting or rack mounting of equipment.
- Provides protection where equipment may be hosed down or otherwise be very wet, or in specific applications where corrosion is a serious problem.
- A variety of inner panels, rack mounting rails and swing out frames are available to provide flexibility in mounting arrangements.
Standards
- UL 508A Type 3R, 4, 4X and 12
- CSA Type 3R, 4, 4X and 12
- Complies with
- NEMA Type 3R, 4, 4X, 12 and 13
- IEC 60529, IP66
Construction
- Formed 12 gauge 304 or 316 stainless steel.
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Heavy duty stainless steel lifting eyebolts are provided with reinforcing support angles.
- Doors are supported with heavy gauge continuous hinges.
- Doors are secured with quarter turn latches.
- Seamless poured-in place gasket.
- Mounting channels are welded on the inside of the enclosure for mounting of optional inner panels or rack equipment rails.
- A grounding stud is provided in the enclosure and a bonding stud is provided on the door.
Finish
- Cover and enclosure are natural stainless steel with a smooth brushed finish.
- Optional inner panels are finished in white powder paint.
Accessories
Inner Panels
Panel Rails
Swing Out Frames
Door Stop Kit
Drip Shield Kit
Quarter Turn Inserts and Keys
Climate Control
Window Kits
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
304 S.S. 316 S.S. Enclosure Optional Full Size Part No. Part No. H W D Inner Pannel 1418N4SSW18QT 1418N4S16W18QT 72.06 25.06 18.06 72WFW 1418N4SSX24QT 1418N4S16X24QT 72.06 31.06 24.06 72XFW 1418N4SSY24QT 1418N4S16Y24QT 72.06 37.06 24.06 72YFW SKU: 1418N4SSW18QT -
Discontinued Products
Type 4X Stainless Steel Two Door Wallmount Enclosure HN4 WM SS Series – (HN4WM426012SS) (DISCONTINUED)
Discontinued ProductsType 4X Stainless Steel Two Door Wallmount Enclosure HN4 WM SS Series – (HN4WM426012SS) (DISCONTINUED)
Application
- Designed to house electrical, electronic, hydraulic or pneumatic controls and instruments.
- Provides protection where equipment may be hosed down or otherwise be very wet, or in specific applications where corrosion is a serious problem.
Construction
- Formed 12 gauge 304 or 316 stainless steel.
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Doors are supported with heavy gauge continuous hinges.
- 3-pt padlocking door handle.
- Seamless poured-in place gasket.
- A grounding stud is provided in the enclosure and a bonding stud is provided on the door.
- Center post is removable for easy installation of the inner panel.
Standards
- UL 508A Type 3R, 4X, and 12
- CSA Type 3R, 4X, and 12
- Complies with
- NEMA Type 3R, 4X, 12 and 13
- IEC 60529, IP66
Finish
- Cover and enclosure are natural stainless steel with a smooth brushed finish.
- Removable inner panel is finished in white powder coating.
Accessories
Door Stop Kit
Type 12/4, 4X Handle Kits
Drip Shield Kit
Window Kits
Mechanical Interlock
Barrier Kits for Type 4 Wallmount
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
304 S.S. 316 S.S. Enclosure Panel Part Number Part Number H W D H W HN4WM24428SS HN4WM24428S16 24.00 42.00 8.00 21.00 39.00 HN4WM24488SS HN4WM24488S16 24.00 48.00 8.00 21.00 45.00 HN4WM304210SS HN4WM304210S16 30.00 42.00 10.00 27.00 39.00 HN4WM304810SS HN4WM304810S16 30.00 48.00 10.00 27.00 45.00 HN4WM306010SS HN4WM306010S16 30.00 60.00 10.00 27.00 57.00 HN4WM364212SS HN4WM364212S16 36.00 42.00 12.00 33.00 39.00 HN4WM364812SS HN4WM364812S16 36.00 48.00 12.00 33.00 45.00 HN4WM366012SS HN4WM366012S16 36.00 60.00 12.00 33.00 57.00 HN4WM424212SS HN4WM424212S16 42.00 42.00 12.00 39.00 39.00 HN4WM424812SS HN4WM424812S16 42.00 48.00 12.00 39.00 45.00 HN4WM426012SS HN4WM426012S16 42.00 60.00 12.00 38.00 56.00 HN4WM484812SS HN4WM484812S16 48.00 48.00 12.00 44.00 44.00 SKU: HN4WM426012SS -
UPS, UPS, Power Solutions, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Line Interactive Lead Acid – 2200VA Power Capcity / 120V /2 Post Mounting / 1 SNMP Card / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
UPS, UPS, Power Solutions, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Line Interactive Lead Acid – 2200VA Power Capcity / 120V /2 Post Mounting / 1 SNMP Card / 2 External Barry Pack – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-LILA-220A-120-2BP-1M-0BY-2P -
Discontinued Products
Type 4 Mild Steel Two Door Floormount Enclosure HN4 FM Series – (HN4FM727224) (DISCONTINUED)
Discontinued ProductsType 4 Mild Steel Two Door Floormount Enclosure HN4 FM Series – (HN4FM727224) (DISCONTINUED)
Application
- Designed to house electrical, electronic, hydraulic or pneumatic controls and instruments.
- Provides protection where equipment may be hosed down or otherwise be very wet, or in outdoor applications for full weather protection.
Construction
- Enclosures are formed steel – 12 gauge (60″ high) or combination 10/12 gauge (72″ high).
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Lifting eyes provide for easy enclosure handling.
- Doors are supported with heavy gauge continuous hinges.
- 3-pt padlocking door handle.
- Seamless poured-in place gasket.
- Provision for light kit mounting.
- A grounding stud is provided in the enclosure and a bonding stud is provided on the door.
- Center post is removable for easy installation of the inner panel.
- 12″ floor stands are welded to the enclosure.
- Body stiffeners are provided in the larger enclosures for extra rigidity.
- Formed lip on door and top of enclosure opening exclude flowing liquids and contaminants.
- A removable 10 gauge inner panel is included.
- Panel supports are provided for easy panel installation.
- Collar studs are provided for mounting inner panels.
- A literature pocket is provided for the inside of the door.
Standards
- UL 508A Type 3R, 4 and 12
- CSA Type 3R, 4 and 12
- Complies with:
- NEMA Type 3R, 4, 12 and 3
- IEC 60529, IP66
Finish
- Cover and enclosure are finished in recoatable smooth ANSI 61 gray powder coating.
- Removable white inner panel is finished in white powder coating.
Accessories
Additional Inner Panels
Door Stop Kit
Barrier Kits for Type 4 Floormount
Mechanical Interlock
Drip Shield Kit
Top Hat Cable Modules
Enclosure Stabilizers
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Inner Panel Part No. H W D H W HN4FM604810 60.13 48.06 10.69 56.00 44.00 HN4FM604818 60.13 48.06 18.69 56.00 44.00 HN4FM606012 60.13 60.06 12.69 56.00 56.00 HN4FM606018 60.13 60.06 18.69 56.00 56.00 HN4FM726012 72.13 60.06 12.69 68.00 56.00 HN4FM726018 72.13 60.06 18.69 68.00 56.00 HN4FM727212 72.13 72.06 12.69 68.00 68.00 HN4FM727218 72.13 72.06 18.69 68.00 68.00 HN4FM727224 72.13 72.06 24.69 68.00 68.00 SKU: HN4FM727224 -
Discontinued Products
Type 12 Mild Steel Two Door Floormount Disconnect Enclosure 2UD CP F Series – (2UDCP727318FFTC) (DISCONTINUED)
Discontinued ProductsType 12 Mild Steel Two Door Floormount Disconnect Enclosure 2UD CP F Series – (2UDCP727318FFTC) (DISCONTINUED)
Application
- Designed to accept the following disconnect switches and circuit breakers:
- ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers.
- Allen Bradley 1494F flange mounted disconnect switches and 1494D flange mounted operators for circuit breakers. Allen Bradley 1494V variable depth flange mounted disconnect switches and circuit breaker mechanisms.
- C-H Westinghouse Type C361 disconnect swtches and operator mechanisms, and type C371 circuit breakers and circuit breaker operating mechanisms. Flex ShaftTM handle operators for circuit breakers.
- General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra-Flex™ cable operators for circuit breakers.
- Siemens I-T-E Max-Flex™ flange mounted variable depth operating handles for disconnect switches and circuit breakers.
- Square D disconnect switches and circuit breakers used with Class 9422 flange mounted variable depth operating mechanisms or cable mechanisms. These enclosures will not receive Class 9422 bracket mounted disconnect devices, Class 9422TG1, or TG2 devices.
- Refer to the Universal Disconnect Selection Guide.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12
- IEC 60529, IP54
- Appropriate components are required to maintain these standards.
Construction
- Formed from 10 gauge steel with smooth, continuously welded seams.
- Body stiffeners are included in the larger enclosures for extra rigidity.
- 15″ floor stands are welded to the enclosure.
- Flange trough Collar (FTC) around door opening excludes liquids and contaminants.
- Heavy duty lifting eyes are anchored into reinforced top corners.
- Removable doors are secured with heavy duty lift-off hinges.
- Formed 10 gauge steel inner panels are provided on collar studs.
- Panel supports are provided.
- Center post is removable, providing easy panel installation.
- Heavy duty three point latching mechanism with heavy duty roller ends is provided for ease of door closing.
- Oil resistant gaskets are permanently secured.
- The left door is the master door.
- Master door handle complete with screw defeater and padlock hasp.
- Slave door handle complete with padlock hasp.
- A mechanical interlock activated by the master door prevents the auxiliary door from being opened first.
- The universal flange cutout provides mounting for disconnect operators by use of the appropriate operator adaptor kit.
- A provision for mounting fluorescent lighting is provided.
- A bonding stud is provided in the door and a grounding stud is provided in the enclosure for each door.
- A literature pocket is provided.
Note
- Disconnect switches, circuit breakers and operators are not provided with the enclosure, and must be ordered separately from the manufacturer.
Finish
- Cover and enclosure are phosphatized and finished in recoatable smooth ANSI 61 gray powder coating.
- Inner panel is finished in white powder coating.
Accessories
Flange Disconnect Operator Adaptor Kits
Additional Inner Panels
Door Stop Kit
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Inner Panel Part No. H W D H W 2UDCP604912FFTC 60.13 48.88 12.13 56.00 44.00 2UDCP606112FFTC 60.13 60.88 12.13 56.00 56.00 2UDCP726112FFTC 72.13 60.88 12.13 68.00 56.00 2UDCP727312FFTC 72.13 72.88 12.13 68.00 68.00 2UDCP727318FFTC 72.13 72.88 18.13 68.00 68.00 SKU: 2UDCP727318FFTC - Designed to accept the following disconnect switches and circuit breakers:
-
Discontinued Products
Type 12 Mild Steel Two Door Floormount Disconnect Enclosure 2UD F Series – (2UD727418FFTC) (DISCONTINUED)
Discontinued ProductsType 12 Mild Steel Two Door Floormount Disconnect Enclosure 2UD F Series – (2UD727418FFTC) (DISCONTINUED)
Application
- Designed to accept the following disconnect switches and circuit breakers:
- ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers.
- Allen Bradley 1494F flange mounted disconnect switches and 1494D flange mounted operators for circuit breakers. Allen Bradley 1494V variable depth flange mounted disconnect switches and circuit breaker mechanisms.
- C-H Westinghouse Type C361 disconnect swtches and operator mechanisms, and type C371 circuit breakers and circuit breaker operating mechanisms. Flex ShaftTM handle operators for circuit breakers.
- General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra-Flex™ cable operators for circuit breakers.
- Siemens I-T-E Max-Flex™ flange mounted variable depth operating handles for disconnect switches and circuit breakers.
- Square D disconnect switches and circuit breakers used with Class 9422 flange mounted variable depth operating mechanisms or cable mechanisms. These enclosures will not receive Class 9422 bracket mounted disconnect devices, Class 9422TG1, or TG2 devices.
- Refer to the Universal Disconnect Selection Guide.
Operator Adaptor Kits
- All universal series enclosures require one adaptor kit (ordered separately) to adapt the type of disconnect and mechanism to be used.
- Each brand and type requires a different adaptor kit.
- Each kit contains an adaptor plate and master door interlocking mechanism.
- Fully detailed, illustrated instructions are included.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12
- IEC 60529, IP54
- Appropriate components are required to maintain these standards.
Construction
- Formed from 10 gauge steel with smooth, continuously welded seams.
- Body stiffeners are included in the larger enclosures for extra rigidity.
- Flange trough collar (FTC) around door opening excludes liquids and contaminants.
- 15″ floor stands are welded to the enclosure.
- Removable doors are secured with heavy duty lift-off hinges.
- Formed 10 gauge steel inner panels are provided on collar studs.
- Panel supports are provided.
- Center post is removable, providing easy panel installation.
- Heavy duty three point latching mechanism with heavy duty roller ends is provided for ease of door closing.
- Oil resistant gaskets are permanently secured.
- The right hand door is the master door.
- Master door handle complete with screw defeater and padlock hasp.
- Slave door handle complete with padlock hasp.
- A mechanical interlock activated by the master door prevents the auxiliary door from being opened first.
- The universal flange cutout provides mounting for disconnect operators by use of the appropriate operator adaptor kit.
- A provision for mounting fluorescent lighting is provided.
- A bonding stud is provided in the door and a grounding stud is provided in the enclosure for each door.
- A literature pocket is provided.
Note
- Disconnect switches, circuit breakers and operators are not provided with the enclosure, and must be ordered separately from the manufacturer.
Finish
- Cover and enclosure are phosphatized and finished in recoatable smooth ANSI 61 gray powder coating.
- Inner panel is finished in white powder coating.
Accessories
Flange Disconnect Operator Adaptor Kits
Additional Inner Panels
Door Stop Kit
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Inner Panel Part No. H W D H W 2UD605012FFTC 60.13 50.00 12.13 56.00 44.00 2UD605018FFTC 60.13 50.00 18.13 56.00 44.00 2UD606212FFTC 60.13 62.00 12.13 56.00 56.00 2UD606218FFTC 60.13 62.00 18.13 56.00 56.00 2UD726212FFTC 72.13 62.00 12.13 68.00 56.00 2UD726218FFTC 72.13 62.00 18.13 68.00 56.00 2UD727412FFTC 72.13 74.00 12.13 68.00 68.00 2UD727418FFTC 72.13 74.00 18.13 68.00 68.00 2UD727424FFTC 72.13 74.00 24.13 68.00 68.00 SKU: 2UD727418FFTC - Designed to accept the following disconnect switches and circuit breakers:
-
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Online: Lead Acid – 2000V Power Capcity / 120V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module / 2 External Battery – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Online: Lead Acid – 2000V Power Capcity / 120V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module / 2 External Battery – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-ONLA-200A-120-2BP-1M-1BY-4P -
Discontinued Products
Type 4 Two Door Freestanding Enclosure HN4 FSTD Series – (HN4FS726036DA) (DISCONTINUED)
Discontinued ProductsType 4 Two Door Freestanding Enclosure HN4 FSTD Series – (HN4FS726036DA) (DISCONTINUED)
Application
- Designed to house electrical, electronic, hydraulic or pneumatic controls and instruments.
- Provides protection where equipment may be hosed down or otherwise be very wet, or in specific applications.
Construction
- Formed 12 gauge steel.
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Heavy duty stainless steel lifting eyebolts are provided with reinforcing support angles.
- Doors are supported with heavy gauge continuous hinges.
- Dual Access versions have doors front and back.
- 3-pt padlocking door handle.
- Seamless poured-in place gasket.
- A grounding stud is provided in the enclosure and a bonding stud is provided on the door.
- Center post is removable for easy installation of the inner panel.
Standards
- UL 508A Type 3R, 4 and 12
- CSA Type 3R, 4 and 12
- Complies with:
- NEMA Type 3R, 4, 12 and 13
- IEC 60529, IP66
Finish
- Cover and enclosure are finished in recoatable smooth ANSI 61 gray powder coating.
- Optional inner panels are available in white powder coating, or unpainted galvanized steel.
Accessories
Inner Panels
Center Panel Supports
Panel Rails
Swing Out Frames
Door Stop Kit
Top Hat Cable Modules
Drip Shield Kit
Type 12/4, 4X Handle Kits
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Single Access
Units shown: inch. Switch units to: mm
Enclosure Part No. H W D Optional
Full Panel¹HN4FS604818 60.00 48.00 18.00 60AWFW HN4FS724818 72.00 48.00 18.00 72ZWFW HN4FS726018 72.00 60.00 18.00 72ZXFW HN4FS727218 72.00 72.00 18.00 72ZYFW HN4FS904820 90.00 48.00 20.00 90BWFW HN4FS907220 90.00 72.00 20.00 90BYFW HN4FS724824 72.00 48.00 24.00 72ZWFW HN4FS726024 72.00 60.00 24.00 72ZXFW HN4FS727224 72.00 72.00 24.00 72ZYFW HN4FS907224 90.00 72.00 24.00 90BYFW HN4FS726036 72.00 60.00 36.00 72ZXFW HN4FS907236 90.00 72.00 36.00 90BYFW Dual Access
Units shown: inch. Switch units to: mm
Enclosure Part No. H W D Optional
Full Panel¹HN4FS724824DA 72.00 48.00 24.00 72ZWFW HN4FS726024DA 72.00 60.00 24.00 72ZXFW HN4FS727224DA 72.00 72.00 24.00 72ZYFW HN4FS907224DA 90.00 72.00 24.00 90BYFW HN4FS726036DA 72.00 60.00 36.00 72ZXFW SKU: HN4FS726036DA -
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Online: Lead Acid – 2000V Power Capcity / 240V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module / 2 External Battery – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Online: Lead Acid – 2000V Power Capcity / 240V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module / 2 External Battery – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-ONLA-200A-240-2BP-1M-1BY-4P -
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Online: Lead Acid – 3000V Power Capcity / 120V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module / 1 External Battery – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Online: Lead Acid – 3000V Power Capcity / 120V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module / 1 External Battery – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-ONLA-300A-120-1BP-1M-1BY-4P -
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Online: Lithium Ion – 3000VA Power Capcity / 240V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Online: Lithium Ion – 3000VA Power Capcity / 240V /4 Post Mounting / 1 SNMP Card / 1 Bypass Module – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-ONLI-300A-240-1BP-1M-0BY-4P -
Discontinued Products
Type 4 Two Door Freestanding Enclosure HN4 FSTD Series – (HN4FS907224) (DISCONTINUED)
Discontinued ProductsType 4 Two Door Freestanding Enclosure HN4 FSTD Series – (HN4FS907224) (DISCONTINUED)
Application
- Designed to house electrical, electronic, hydraulic or pneumatic controls and instruments.
- Provides protection where equipment may be hosed down or otherwise be very wet, or in specific applications.
Construction
- Formed 12 gauge steel.
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Heavy duty stainless steel lifting eyebolts are provided with reinforcing support angles.
- Doors are supported with heavy gauge continuous hinges.
- Dual Access versions have doors front and back.
- 3-pt padlocking door handle.
- Seamless poured-in place gasket.
- A grounding stud is provided in the enclosure and a bonding stud is provided on the door.
- Center post is removable for easy installation of the inner panel.
Standards
- UL 508A Type 3R, 4 and 12
- CSA Type 3R, 4 and 12
- Complies with:
- NEMA Type 3R, 4, 12 and 13
- IEC 60529, IP66
Finish
- Cover and enclosure are finished in recoatable smooth ANSI 61 gray powder coating.
- Optional inner panels are available in white powder coating, or unpainted galvanized steel.
Accessories
Inner Panels
Center Panel Supports
Panel Rails
Swing Out Frames
Door Stop Kit
Top Hat Cable Modules
Drip Shield Kit
Type 12/4, 4X Handle Kits
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Single Access
Units shown: inch. Switch units to: mm
Enclosure Part No. H W D Optional
Full Panel¹HN4FS604818 60.00 48.00 18.00 60AWFW HN4FS724818 72.00 48.00 18.00 72ZWFW HN4FS726018 72.00 60.00 18.00 72ZXFW HN4FS727218 72.00 72.00 18.00 72ZYFW HN4FS904820 90.00 48.00 20.00 90BWFW HN4FS907220 90.00 72.00 20.00 90BYFW HN4FS724824 72.00 48.00 24.00 72ZWFW HN4FS726024 72.00 60.00 24.00 72ZXFW HN4FS727224 72.00 72.00 24.00 72ZYFW HN4FS907224 90.00 72.00 24.00 90BYFW HN4FS726036 72.00 60.00 36.00 72ZXFW HN4FS907236 90.00 72.00 36.00 90BYFW Dual Access
Units shown: inch. Switch units to: mm
Enclosure Part No. H W D Optional
Full Panel¹HN4FS724824DA 72.00 48.00 24.00 72ZWFW HN4FS726024DA 72.00 60.00 24.00 72ZXFW HN4FS727224DA 72.00 72.00 24.00 72ZYFW HN4FS907224DA 90.00 72.00 24.00 90BYFW HN4FS726036DA 72.00 60.00 36.00 72ZXFW SKU: HN4FS907224