American Tech Supply Full Catalog
Showing 961–984 of 75476 results
-
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Online: Lead Acid – 3000V Power Capcity / 240V /4 Post Mounting / 1 Bypass Module / 1 External Battery – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Online: Lead Acid – 3000V Power Capcity / 240V /4 Post Mounting / 1 Bypass Module / 1 External Battery – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-ONLA-300A-240-1BP-0M-1BY-4P -
Discontinued Products
Type 12 Mild Steel Two Door Floormount Disconnect Enclosure 2UD F Series – (2UD726212FFTC) (DISCONTINUED)
Discontinued ProductsType 12 Mild Steel Two Door Floormount Disconnect Enclosure 2UD F Series – (2UD726212FFTC) (DISCONTINUED)
Application
- Designed to accept the following disconnect switches and circuit breakers:
- ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers.
- Allen Bradley 1494F flange mounted disconnect switches and 1494D flange mounted operators for circuit breakers. Allen Bradley 1494V variable depth flange mounted disconnect switches and circuit breaker mechanisms.
- C-H Westinghouse Type C361 disconnect swtches and operator mechanisms, and type C371 circuit breakers and circuit breaker operating mechanisms. Flex ShaftTM handle operators for circuit breakers.
- General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra-Flex™ cable operators for circuit breakers.
- Siemens I-T-E Max-Flex™ flange mounted variable depth operating handles for disconnect switches and circuit breakers.
- Square D disconnect switches and circuit breakers used with Class 9422 flange mounted variable depth operating mechanisms or cable mechanisms. These enclosures will not receive Class 9422 bracket mounted disconnect devices, Class 9422TG1, or TG2 devices.
- Refer to the Universal Disconnect Selection Guide.
Operator Adaptor Kits
- All universal series enclosures require one adaptor kit (ordered separately) to adapt the type of disconnect and mechanism to be used.
- Each brand and type requires a different adaptor kit.
- Each kit contains an adaptor plate and master door interlocking mechanism.
- Fully detailed, illustrated instructions are included.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12
- IEC 60529, IP54
- Appropriate components are required to maintain these standards.
Construction
- Formed from 10 gauge steel with smooth, continuously welded seams.
- Body stiffeners are included in the larger enclosures for extra rigidity.
- Flange trough collar (FTC) around door opening excludes liquids and contaminants.
- 15″ floor stands are welded to the enclosure.
- Removable doors are secured with heavy duty lift-off hinges.
- Formed 10 gauge steel inner panels are provided on collar studs.
- Panel supports are provided.
- Center post is removable, providing easy panel installation.
- Heavy duty three point latching mechanism with heavy duty roller ends is provided for ease of door closing.
- Oil resistant gaskets are permanently secured.
- The right hand door is the master door.
- Master door handle complete with screw defeater and padlock hasp.
- Slave door handle complete with padlock hasp.
- A mechanical interlock activated by the master door prevents the auxiliary door from being opened first.
- The universal flange cutout provides mounting for disconnect operators by use of the appropriate operator adaptor kit.
- A provision for mounting fluorescent lighting is provided.
- A bonding stud is provided in the door and a grounding stud is provided in the enclosure for each door.
- A literature pocket is provided.
Note
- Disconnect switches, circuit breakers and operators are not provided with the enclosure, and must be ordered separately from the manufacturer.
Finish
- Cover and enclosure are phosphatized and finished in recoatable smooth ANSI 61 gray powder coating.
- Inner panel is finished in white powder coating.
Accessories
- Flange Disconnect Operator Adaptor Kits
- Additional Inner Panels
- Door Stop Kit
- Window Kits
- Climate Control
- Lighting
- General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Inner Panel Part No. H W D H W 2UD605012FFTC 60.13 50.00 12.13 56.00 44.00 2UD605018FFTC 60.13 50.00 18.13 56.00 44.00 2UD606212FFTC 60.13 62.00 12.13 56.00 56.00 2UD606218FFTC 60.13 62.00 18.13 56.00 56.00 2UD726212FFTC 72.13 62.00 12.13 68.00 56.00 2UD726218FFTC 72.13 62.00 18.13 68.00 56.00 2UD727412FFTC 72.13 74.00 12.13 68.00 68.00 2UD727418FFTC 72.13 74.00 18.13 68.00 68.00 2UD727424FFTC 72.13 74.00 24.13 68.00 68.00 SKU: 2UD726212FFTC - Designed to accept the following disconnect switches and circuit breakers:
-
Discontinued Products
Type 12 Mild Steel Two Door Wallmount Disconnect Enclosure 2UD Series – (2UD726212FTC) (DISCONTINUED)
Discontinued ProductsType 12 Mild Steel Two Door Wallmount Disconnect Enclosure 2UD Series – (2UD726212FTC) (DISCONTINUED)
Application
- Designed to accept the following disconnect switches and circuit breakers:
- ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers.
- Allen Bradley 1494F flange mounted disconnect switches and 1494D flange mounted operators for circuit breakers. Allen Bradley 1494V variable depth flange mounted disconnect switches and circuit breaker mechanisms.
- C-H Westinghouse Type C361 disconnect swtches and operator mechanisms, and type C371 circuit breakers and circuit breaker operating mechanisms. Flex ShaftTM handle operators for circuit breakers.
- General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra-Flex™ cable operators for circuit breakers.
- Siemens I-T-E Max-Flex™ flange mounted variable depth operating handles for disconnect switches and circuit breakers.
- Square D disconnect switches and circuit breakers used with Class 9422 flange mounted variable depth operating mechanisms or cable mechanisms. These enclosures will not receive Class 9422 bracket mounted disconnect devices, Class 9422TG1, or TG2 devices.
- Refer to the Universal Disconnect Selection Guide.
Operator Adaptor Kits
- All universal series enclosures require one adaptor kit (ordered separately) to adapt the type of disconnect and mechanism to be used.
- Each brand and type requires a different adaptor kit.
- Each kit contains an adaptor plate and master door interlocking mechanism.
- Fully detailed, illustrated instructions are included.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12 and 13
- IEC 60529, IP54
- Appropriate components are required to maintain these standards.
Construction
- Formed from 10 gauge steel with smooth, continuously welded seams.
- Body stiffeners are included in the larger enclosures for extra rigidity.
- Heavy duty lifting eyes are anchored into reinforced top corners.
- Flange trough collar (FTC) around door opening excludes liquids and contaminants.
- Removable doors are secured with heavy duty lift-off hinges.
- Formed 10 gauge steel inner panels are provided on collar studs.
- Panel supports are provided.
- Center post is removable, providing easy panel installation.
- Heavy duty three point latching mechanism with heavy duty roller ends is provided for ease of door closing.
- Oil resistant gaskets are permanently secured.
- The right hand door is the master door.
- Master door handle complete with screw defeater and padlock hasp.
- Slave door handle complete with padlock hasp.
- A mechanical interlock activated by the master door prevents the auxiliary door from being opened first.
- The universal flange cutout provides mounting for disconnect operators by use of the appropriate operator adaptor kit.
- A provision for mounting fluorescent lighting is provided.
- A bonding stud is provided in the door and a grounding stud is provided in the enclosure for each door.
- A literature pocket is provided for the inside of the door.
Note
- Disconnect switches, circuit breakers and operators are not provided with the enclosure, and must be ordered separately from the manufacturer.
Finish
- Door and enclosure are phosphatized and finished in ANSI 61 gray recoatable powder coating on the inside and outside.
- Inner panel is finished in white powder coating.
Accessories
- Flange Disconnect Operator Adaptor Kits
- Additional Inner Panels
- Door Stop Kit
- Floor Stand Kit
- Window Kits
- Climate Control
- Lighting
- General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Inner Panel Part No. H W D H W 2UD605012FTC 60.13 50.00 12.13 56.00 44.00 2UD606212FTC 60.13 62.00 12.13 56.00 56.00 2UD726212FTC 72.13 62.00 12.13 68.00 56.00 2UD727412FTC 72.13 74.00 12.13 68.00 68.00 SKU: 2UD726212FTC - Designed to accept the following disconnect switches and circuit breakers:
-
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great Lakes
UPS Solutions Online: Lead Acid – 3000V Power Capcity / 240V /4 Post Mounting / 1 SNMP Card / 1 External Battery – Great Lakes Data Racks and Cabinets
Power Solutions, UPS, UPS, Data Cabinets and Racks, Power Solutions, Great LakesUPS Solutions Online: Lead Acid – 3000V Power Capcity / 240V /4 Post Mounting / 1 SNMP Card / 1 External Battery – Great Lakes Data Racks and Cabinets
Suggested pricing, call for discounts
SKU: GLUPS-ONLA-300A-240-1BP-1M-0BY-4P -
Discontinued Products
Type 4X Stainless Steel Wallmount Enclosure 1418 N4 SS Series – (1418N4S16T16) (DISCONTINUED)
Discontinued ProductsType 4X Stainless Steel Wallmount Enclosure 1418 N4 SS Series – (1418N4S16T16) (DISCONTINUED)
Application
- Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures.
- Provides protection where equipment may be hosed down or otherwise be very wet, or in specific applications where corrosion is a serious problem.
Standards
- UL 508A Type 3R, 4, 4X, and 12
- CSA Type 3R, 4, 4X, and 12
- Complies with
- NEMA Type 3R, 4, 4X, 12 and 13
- IEC 60529, IP66
Construction
- Formed 14 gauge 304 or 316 stainless steel.
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Door stiffeners are provided in the larger enclosures for extra rigidity.
- Welded brackets provide for enclosure mounting.
- Formed lip on door and enclosure excludes flowing liquids and contaminants.
- Stainless steel continuous hinge on door may be removed by pulling the stainless steel hinge pin.
- Door is secured with easily operated stainless steel clamps.
- Provision for padlocking.
- Seamless poured-in place gasket.
- A removable 12 gauge inner panel is included.
- Collar studs are provided for mounting inner panels.
- A bonding stud is provided on the door and a grounding stud is provided in the enclosure.
- A literature pocket is provided for the inside of the door.
Finish
- Cover and enclosure are natural stainless steel with a smooth brushed finish.
- Removable inner panel is finished in white powder coating.
Accessories
- Additional Inner Panels
- Perforated Inner Panels
- Swing Panel Kit
- Door Stop Kit
- Door Clamping Hardware
- Wallmount Quick Release Clamp
- Drip Shield Kit
- Floor Stand Kit
- Window Kits
- Climate Control
- Lighting
- General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm