American Tech Supply Full Catalog
Showing 1321–1344 of 75476 results
-
Discontinued Products
5000-12000 BTU/H Indoor Air Conditioner DTS Series – (DTS3145A230LG) (DISCONTINUED)
Discontinued Products5000-12000 BTU/H Indoor Air Conditioner DTS Series – (DTS3145A230LG) (DISCONTINUED)
Description
- Designed for side mounting on any enclosure surface where high capacity system cooling is required.
- Closed loop cooling ensures clean enclosure air is recirculated
without ever mixing with contaminated ambient air. - Optimum air circulation with maximum clearance distance between warm inlet and cold outlet for reduced hot spot locations.
- Condensor with 3 mm fin spacing, highly effective protection
against strongly contaminated and aggressive ambient air
Standards
- Maintains enclosure’s NEMA 12 rating
- IP 54
- UL, cUL and CE
Features
- R134a refrigerant.
- Thermostat control accessible from inside enclosure.
- Hot gas bypass valve prevents evaporator freeze up while
minimizing heavy inrush currents on large BTU/H units. - Built in condensate evaporator.
- Continuous air circulation from high capacity fans.
- EMI/RFI suppression meets CE.
- Self-diagnostics on startup.
- Fault indication via LED light.
- Provision for door contact allowing power down when
enclosure door is opened. - Gasket, mounting kit and template for enclosure cutout and
drilling are included. - Condensate drain hose and clamp provided.
Accessories
SKU: DTS3145A230LG -
Discontinued Products
Type 4X Stainless Steel Wallmount Disconnect Enclosure 1447S N4 SS Series – (1447SN4SSK12) (DISCONTINUED)
Discontinued ProductsType 4X Stainless Steel Wallmount Disconnect Enclosure 1447S N4 SS Series – (1447SN4SSK12) (DISCONTINUED)
Application
- Designed to house the following safety disconnect equipment:
- ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers. Cable version for circuit breakers also available.
- Allen Bradley 1494V variable depth flange mounted disconnect switches and circuit breaker operators NEMA 4 rated. Will not accept Allen Bradley 1494F disconnect switches, 1494D circuit breaker operators or 1494V-R1, -R2, or -W2 operating handles).
- Cutler Hammer C361 variable depth flange mounted disconnect switches and C371 circuit breaker operators. Also Flex-Shaft™ handle mechanisms for circuit breakers. Use Cutler Hammer NEMA 4X rated operating handles to maintain NEMA 4X integrity.
- Siemens I-T-E Max-Flex™ flange mounted variable depth handles for disconnect switch and circuit breakers. Use handle for NEMA 4 rating.
- General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also SpectraFlex™ cable operators for circuit breakers.
- Square D Class 9422 disconnect switches with flange mounted variable depth operating mechanisms or cable mechanisms and Class 9422 flange mounted variable depth operating mechanism or cable mechanisms for circuit breakers. SN4SS enclosures will not accept Square D Class 9422 bracket-mounted disconnect devices, 9422TG1 or TG2 devices.
- Refer to the Type 4 Wallmount Selection Guide.
Standards
- UL 508A Type 3R, 4 and 4X
- CSA Type 3R, 4 and 4X
- Complies with
- NEMA Type 3R, 4, 4X, 12 and 13
- IEC 60529, IP66
- Appropriate components are required to maintain these standards.
Construction
- Formed 14 gauge type 304 stainless steel.
- Continuously welded seams.
- Larger sizes include door and body stiffeners.
- Formed lip on door and enclosure exclude flowing liquids and contaminants.
- Cutouts and holes are provided to suit the flange handle operating mechanism.
- Continuously hinged doors may be removed by pulling the stainless steel hinge pin.
- Door is secured with easily operated stainless steel clamps.
- Cover interlock bracket is welded to the door.
- Collar studs are provided for mounting inner panels.
- A removable 12 gauge inner panel is included.
- Seamless poured-in place gasket.
- A bonding stud is provided on the door and a grounding stud is provided in the enclosure.
- A literature pocket is provided for the inside of the door.
Finish
- Disconnects and operating mechanisms are not provided with the enclosure, and must be ordered separately from the manufacturer.
Accessories
Additional Inner Panels
Door Stop Kit
Floor Stand Kit
Drip Shield Kit
Door Clamping Hardware
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Inner Panel Part No. H W D H W 1447SN4SSB8 24.00 21.38 8.00 21.00 17.00 1447SN4SSC8 24.00 25.38 8.00 21.00 21.00 1447SN4SSE8 30.00 25.38 8.00 27.00 21.00 1447SN4SSF8 36.00 25.38 8.00 33.00 21.00 1447SN4SSG8 36.00 31.38 8.00 33.00 27.00 1447SN4SSH12 42.00 31.38 12.00 39.00 27.00 1447SN4SSJ12 42.00 37.38 12.00 39.00 33.00 1447SN4SSK12 48.00 37.38 12.00 45.00 33.00 1447SN4SSL12 60.00 37.38 12.00 57.00 33.00 SKU: 1447SN4SSK12 - Designed to house the following safety disconnect equipment:
-
Discontinued Products
Type 12 Mild Steel Two Door Floormount Enclosure 1422 FM Series – (1422E16) (DISCONTINUED)
Discontinued ProductsType 12 Mild Steel Two Door Floormount Enclosure 1422 FM Series – (1422E16) (DISCONTINUED)
Application
- Designed to house electrical, electronic, hydraulic or pneumatic controls and instruments.
- Provides a degree of protection from falling dirt, dust, oil and water.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Enclosures are formed steel – 14 gauge (54″ high), 12 gauge (60″ high), or combination 10/12 gauge (72″ high).
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Body stiffeners are provided in enclosures for extra rigidity.
- Heavy duty lifting eyebolts are provided with reinforced support angles.
- 12″ floor stands are welded to the enclosure. (w/ feet Part No.).
- Welded brackets provide for enclosure mounting (w/o feet Part No.).
- Gasketed overlapping doors eliminate the need for a center post.
- Continuously hinged doors may be removed by pulling the hinge pin.
- Doors are secured with a three point latch and operated with a key locking, padlockable handle.
- Latch rods are equipped with rollers for easier door closing.
- Oil resistant gaskets are permanently secured.
- A removable 10 gauge inner panel is included in enclosures 60″ and larger. Smaller sizes include a 12 gauge inner panel.
- Provision for light kit mounting.
- Panel supports are provided in enclosures 60″ and larger for easy panel installation.
- Collar studs are provided for mounting inner panels.
- A grounding stud is provided in the enclosure for each door and a bonding stud is provided on the door.
- A literature pocket is provided for the inside of the door.
Finish
- Cover and enclosure are phosphatized and finished in recoatable smooth ANSI 61 gray powder coating.
- Removable inner panel is finished in white powder coating.
Accessories
Additional Inner Panels
Door Stop Kit
Enclosure Stabilizers
Floor Stand Kit
Top Hat Cable Modules
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm