American Tech Supply Full Catalog
Showing 1729–1752 of 75476 results
-
Discontinued Products
Type 4X Stainless Steel Wallmount Disconnect Enclosure Eclipse Series – (EN4DSC483812SS) (DISCONTINUED)
Discontinued ProductsType 4X Stainless Steel Wallmount Disconnect Enclosure Eclipse Series – (EN4DSC483812SS) (DISCONTINUED)
Application
- Designed to house the following safety disconnect equipment:
- ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers. Cable version for circuit breakers also available.
- Allen Bradley 1494V variable depth flange mounted disconnect switches and circuit breaker operators NEMA 4 rated. Will not accept Allen Bradley 1494F disconnect switches, 1494D circuit breaker operators or 1494V-R1, -R2, or -W2 operating handles).
- Cutler Hammer C361 variable depth flange mounted disconnect switches and C371 circuit breaker operators. Also Flex-Shaft™ handle mechanisms for circuit breakers. Use Cutler Hammer NEMA 4X rated operating handles to maintain NEMA 4X integrity.
- Siemens I-T-E Max-Flex™ flange mounted variable depth handles for disconnect switch and circuit breakers. Use handle for NEMA 4 rating.
- General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also SpectraFlex™ cable operators for circuit breakers.
- Square D Class 9422 disconnect switches with flange mounted variable depth operating mechanisms or cable mechanisms and Class 9422 flange mounted variable depth operating mechanism or cable mechanisms for circuit breakers. SN4SS enclosures will not accept Square D Class 9422 bracket-mounted disconnect devices, 9422TG1 or TG2 devices.
- Refer to the Type 4 Wallmount Selection Guide.
Standards
- UL 508A Type 3R, 4 and 4X
- CSA Type 3R, 4 and 4X
- Complies with
- NEMA Type 3R, 4, 4X, 12 and 13
- IEC 60529, IP66
- Appropriate components are required to maintain these standards.
Construction
- Formed 14 gauge doors with 16 or 14 (36×32″ and larger) gauge type 304 stainless steel.
- Continuously welded seams.
- Larger sizes include door stiffeners.
- Formed lip on door and enclosure exclude flowing liquids and contaminants.
- Cutouts and holes are provided to suit the flange handle operating mechanism.
- Doors may be easily removed for modifications and are interchangeable.
- Door is secured with easily operated 2 or 3 point, padlockable handle.
- Cover interlock bracket is included on the door.
- Collar studs are provided for mounting inner panels.
- Removable inner panel is sold separately.
- Seamless poured-in place gasket.
- A bonding stud is provided on the door and a grounding stud is provided in the enclosure.
- Includes hardware kit with panel mounting nuts and sealing washers for wall mounting holes.
Finish
- Disconnects and operating mechanisms are not provided with the enclosure, and must be ordered separately from the manufacturer.
Accessories
Additional Inner Panels
Door Stop Kit
Mounting Foot Kit
Climate Control
Window Kits
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm
Enclosure Optional Inner Panel Part No. H W D Part No. H W EN4DSC20228SS 20.00 22.00 8.00 EP2020 18.17 18.17 EN4DSC24228SS 24.00 22.00 8.00 EP2420 22.17 18.17 EN4DSC24268SS 24.00 26.00 8.00 EP2424 22.17 22.17 EN4DSC30268SS 30.00 26.00 8.00 EP3024 28.17 22.17 EN4DSC36268SS 36.00 26.00 8.00 EP3624 34.17 22.17 EN4DSC36328SS 36.00 32.00 8.00 EP3630 34.17 28.17 EN4DSC423212SS 42.00 32.00 12.00 EP4230 40.17 28.17 EN4DSC423812SS 42.00 38.00 12.00 EP4236 40.17 34.17 EN4DSC483812SS 48.00 38.00 12.00 EP4836 46.17 34.17 EN4DSC603812SS 60.00 38.00 12.00 EP6036 58.17 34.17 SKU: EN4DSC483812SS - Designed to house the following safety disconnect equipment:
-
Discontinued Products
Type 12 Mild Steel Two Door Floormount Enclosure 1422 FM Series – (1422B20) (DISCONTINUED)
Discontinued ProductsType 12 Mild Steel Two Door Floormount Enclosure 1422 FM Series – (1422B20) (DISCONTINUED)
Application
- Designed to house electrical, electronic, hydraulic or pneumatic controls and instruments.
- Provides a degree of protection from falling dirt, dust, oil and water.
Standards
- UL 508A Type 12
- CSA Type 12
- Complies with
- NEMA Type 12
- IEC 60529, IP54
Construction
- Enclosures are formed steel – 14 gauge (54″ high), 12 gauge (60″ high), or combination 10/12 gauge (72″ high).
- Smooth, continuously welded seams without knockouts, cutouts or holes.
- Body stiffeners are provided in enclosures for extra rigidity.
- Heavy duty lifting eyebolts are provided with reinforced support angles.
- 12″ floor stands are welded to the enclosure. (w/ feet Part No.).
- Welded brackets provide for enclosure mounting (w/o feet Part No.).
- Gasketed overlapping doors eliminate the need for a center post.
- Continuously hinged doors may be removed by pulling the hinge pin.
- Doors are secured with a three point latch and operated with a key locking, padlockable handle.
- Latch rods are equipped with rollers for easier door closing.
- Oil resistant gaskets are permanently secured.
- A removable 10 gauge inner panel is included in enclosures 60″ and larger. Smaller sizes include a 12 gauge inner panel.
- Provision for light kit mounting.
- Panel supports are provided in enclosures 60″ and larger for easy panel installation.
- Collar studs are provided for mounting inner panels.
- A grounding stud is provided in the enclosure for each door and a bonding stud is provided on the door.
- A literature pocket is provided for the inside of the door.
Finish
- Cover and enclosure are phosphatized and finished in recoatable smooth ANSI 61 gray powder coating.
- Removable inner panel is finished in white powder coating.
Accessories
Additional Inner Panels
Door Stop Kit
Enclosure Stabilizers
Floor Stand Kit
Top Hat Cable Modules
Window Kits
Climate Control
Lighting
General Accessories
Part Details
Click Part No, below, for details (e.g., Product drawings, assembly instructions, ship weight)
Units shown: inch. Switch units to: mm