Alpine 3802 Chassis |
|
OSPF |
- |
3-slot chassis |
|
- |
RFC 2328 OSPF v2 (including MD5 authentication) |
Port Densities |
|
- |
RFC 1587 OSPF NSSA Option |
- |
20 10/100/1000BASE-T ports |
|
- |
RFC 1765 OSPF Database Overflow |
- |
20 1000BASE-X ports |
|
- |
RFC 2370 OSPF Opaque LSA Option |
- |
64 10/100BASE-TX ports |
|
BGP4 |
- |
64 10/100BASE-TX PoE ports |
|
- |
RFC 1771 Border Gateway Protocol 4 |
- |
48 100BASE-FX MMF ports |
|
- |
RFC 1965 Autonomous System |
- |
48 100BASE-FX SMF ports |
|
- |
Confederations for BGP |
Performance |
|
- |
RFC 1997 BGP Communities Attribute |
- |
16 Gbps switch fabric bandwidth |
|
- |
RFC 1745 BGP/OSPF Interaction |
|
12 Mpps forwarding rate |
|
- |
RFC 2385 TCP MD5 Authentication for BGPv4 |
- |
128K MAC addresses |
|
- |
RFC 2439 BGP Route Flap Damping |
- |
4096 VLANs |
|
IP Multicast |
|
|
- |
RFC 2362 PIM-SM |
|
|
|
- |
PIM-DM Draft IETF PIM Dense Mode v2-dm-03 |
|
|
|
- |
DVMRP v3 draft IETF DVMRP v3-07 |
Physical Dimensions |
|
- |
RFC 1112 IGMP v1 |
- |
Rack height: 4RU |
|
- |
RFC 2236 IGMP v2 |
- |
7.0 in (H) x 17.3 in (W) x 12.0 in (D) |
|
- |
IGMP Snooping with Configurable Router |
- |
17.8 cm (H) x 43.9 cm (W) x 30.5 cm (D) |
|
- |
Registration Forwarding |
|
Weight (empty): 25 lbs (11 kg) |
|
- |
Static IGMP Membership |
- |
Weight (fully loaded): 31 lbs (14 kg) |
|
- |
IGMP Filters |
Power and Heat Dissipation |
|
- |
Mtrace, draft-ietf-idmr-traceroute-imp-07 |
- |
Power Supply Input: 315 Watts |
|
- |
Mrinfo |
- |
Heat Dissipation 1076 BTU/hour |
|
IS-IS |
- |
Current Rating: 4A @ 100 VAC; 2A @ 200 VAC; 8A @ -40VDC |
|
- |
RFC 1142 (ISO 10589), IS-IS protocol |
Alpine 3804 Chassis |
|
- |
RFC 1195 Use of OSI IS-IS for routing in TCP/IP |
- |
5-slot chassis |
|
|
and dual environments |
Port Densities |
|
- |
RFC 2104 HMAC: Keyed-Hashing for |
- |
64 10/100/1000BASE-T ports |
|
|
Message Authentication |
- |
64 1000BASE-X ports |
|
Management and Security |
- |
128 10/100BASE-TX ports |
|
Management - SNMP & MIBs |
- |
128 10/100BASE-TX PoE ports |
|
- |
RFC 1155 Structure of Mgmt Information (SMIv1) |
- |
96 100BASE-FX SMF ports |
|
- |
RFC 1157 SNMPv1 |
Performance |
|
- |
RFC 1212, RFC 1213, RFC 1215 MIB-II & TRAPs |
- |
32 Gbps switch fabric bandwidth |
|
- |
RFC 1901 – 1908 SNMP Version 2c, SMIv2 |
- |
24 Mpps forwarding rate |
|
|
and Revised MIB-II and authentication |
- |
128K MAC addresses |
|
- |
RFC 2576 Coexistence between SNMP Version 1, |
- |
4096 VLANs |
|
- |
Version 2 and Version 3 |
Physical Dimensions |
|
- |
RFC 1757 RMON 4 groups: Stats, History, Alarms |
- |
Rack height: 6RU |
|
|
and Events |
- |
10.5 in (H) x 17.3 in (W) x 15.5 in (D) |
|
- |
RFC 2021 RMON2 (probe configuration) |
- |
26.7 cm (H) x 43.9 cm (W) x 39.4 cm (D) |
|
- |
RFC 2613 SMON MIB |
- |
Weight (empty): 30 lbs (14 kg) |
|
- |
RFC 2668 802.3 MAU MIB |
- |
Weight (fully loaded): 68 lbs (31 kg) |
|
- |
RFC 1643 Ethernet MIB |
Power and Heat Dissipation |
|
- |
Draft-ietf-bridge-rstpmib-03.txt – Definitions of Managed |
- |
Power Supply Input: 577 Watts |
|
- |
Objects for Bridges with Rapid Spanning Tree Protocol |
- |
Heat Dissipation 2000 BTU/hour |
|
- |
RFC 1354 IPv4 Forwarding Table MIB |
- |
Current Rating: 6.5A @ 100 VAC; 3.5A @ |
|
- |
RFC 2037 Entity MIB RFC 2233 Interface MIB |
|
200 VAC; 15A @ -40VDC |
|
- |
RFC 2096 IP Forwarding |
Alpine 3808 Chassis |
|
- |
RFC 1724 RIPv2 MIB |
- |
9-slot chassis |
|
- |
RFC 1850 OSPFv2 MIB |
Port Densities |
|
- |
RFC 1657 BGPv4 MIB |
- |
128 10/100/1000BASE-T ports |
|
- |
RFC 2787 VRRP MIB |
- |
128 1000BASE-X ports |
|
- |
RFC 2925 Ping / Traceroute /NSLOOKUP MIB |
- |
256 10/100BASE-TX ports |
|
- |
ExtremeWare vendor MIB (includes ACL, MAC |
- |
256 10/100BASE-TX PoE ports |
|
- |
FDB, IP FDB, MAC Address Security, QoS |
- |
192 100BASE-FX MMF ports |
|
|
policy and VLAN config) |
- |
192 100BASE-FX SMF ports |
|
- |
IEEE 802.1x – 2001 MIB |
Performance |
|
- |
Extreme extensions to 802.1x-MIB |
- |
64 Gbps switch fabric bandwidth |
|
Management - Other |
- |
48 Mpps forwarding rate |
|
- |
RFC 1866 HTML |
- |
128K MAC addresses |
|
- |
RFC 2068 HTTP |
- |
4096 VLANs |
|
- |
RFC 854 Telnet |
Physical Dimensions |
|
- |
HTML/ HTTP management |
- |
Rack height: 12RU |
|
- |
Secure Shell (SSHv2) and Telnet management, |
- |
21.0 in (H) x 17.3 in (W) x 11.4 in (D) |
|
- |
Telnet and SSHv2 clients |
- |
53.3 cm (H) x 43.9 cm (W) x 28.9 cm (D) |
|
- |
Secure Copy (SCPv2) |
- |
Weight (empty): 50 lbs (23 kg) |
|
-
- |
NetFlow version 1 export
Configuration Logging |
- |
Weight (fully loaded): 100 lbs (45 kg) |
|
- |
Multiple Images, Multiple Configs |
Power and Heat Dissipation |
|
- |
BSD System Logging Protocol (SYSLOG), |
|
Power Supply Input: 1046 Watts |
|
|
with Multiple Syslog Servers |
- |
Heat Dissipation 3600 BTU/hour |
|
- |
999 Local Messages (criticals stored across reboots) |
- |
Current Rating: 13A @ 100 VAC; 6.5A @ |
|
- |
RFC 2030 SNTP, Simple Network Time Protocol v4 |
|
200 VAC; 30A @ -40VDC |
|
Security |
Protocols and Standards |
|
- |
Routing protocol authentication (see above) |
General Routing/Switching |
|
- |
Secure Shell (SSHv2) & Secure Copy (SCPv2) |
- |
RFC 1812 IPv4 Router Requirements |
|
|
with encryption/authentication |
- |
RFC 1519 CIDR |
|
- |
SNMPv3 user based security, with encryption/ |
- |
RFC 1256 IPv4 Router Discovery (IRDP) |
|
|
/authentication (see page 3) |
- |
RFC 783 TFT |
|
- |
RFC 1492 TACACS+ |
- |
RFC 951, 1542 BootP |
|
- |
RFC 2138 RADIUS Authentication |
- |
RFC 2131 BOOTP/DHCP relay agent and |
|
- |
RFC 2139 RADIUS Accounting |
- |
DHCP server |
|
- |
RADIUS Per-command Authentication |
- |
RFC 1591 DNS (client operation) |
|
- |
Access Profiles on All Routing Proto |
- |
RFC 1122 Host Requirements |
|
- |
Access Profiles on All Management Methods |
- |
RFC 768 UDP |
|
- |
Network Login (web-based DHCP/RADIUS mechanism) |
- |
RFC 791 IP |
|
- |
IEEE802.1x – 2001 Port-Based Network Access |
- |
RFC 792 ICMP |
|
- |
Control for Network Login |
- |
RFC 793 TCP |
|
- |
Multiple supplicants for Network Login (web-based and |
- |
RFC 826 ARP |
|
|
802.1x modes) |
- |
RFC 2338 VRRP |
|
- |
MAC Address Security / Lockdown |
- |
Extreme Standby Router Protocol (ESRP) |
|
|
Network Address Translation (NAT) |
- |
IPX RIP/SAP Router specification |
|
- |
Layer 2/3/4/7 Access Control Lists (ACLs) |
- |
IEEE 802.1D-1998 Spanning Tree Protocol (STP) |
|
Safety |
- |
Multiple Instances of Spanning Tree (PVST+ |
|
- |
UL 1950 3rd Edition , Listed (Safety of ITE) |
|
compatible, 802.1Q interoperable) |
|
- |
EN60950:1992/A1-4:1997+ZB/ZC Deviations |
- |
IEEE 802.1w - 2001 Rapid Reconfiguration for STP, RSTP |
|
|
(Safety of ITE) |
- |
IEEE 802.1Q - 1998 Virtual Bridged Local Area Networks |
|
- |
IEC 950CB (Safety of ITE) |
|
Ethernet Automatic Protection Switching (EAPS) |
|
- |
Low Voltage Directive (LVD) |
- |
Software controlled redundant ports |
|
- |
CSA 22.2#950-95 (Safety of ITE) |
Quality of Service and Policies |
|
- |
AS/NZX 3260 (product safety standard) |
- |
IEEE 802.1D -1998 (802.1p) Packet Priority |
|
- |
EN60825-1 (Safety of Lasers Products) |
- |
RFC 2474 DiffServ Precedence, including 8 queues/port |
|
- |
FCC CFR 21 (Laser Products) |
- |
RFC 2598 DiffServ Expedited Forwarding (EF) |
|
EMI/EMC |
- |
RFC 2597 DiffServ Assured Forwarding (AF) |
|
- |
NEBS Level III, Issue 1 |
- |
RFC 2475 DiffServ Core and Edge Router Functions |
|
- |
FCC CFR 47 part 15 Class A (USA EMC standard) |
- |
Bi-directional Rate Shaping |
|
- |
ICES-003A/C108.8-M1983 Class A (Canada |
- |
Layer 1-4, Layer 7 (user name) Policy-Based Mapping |
|
|
EMC standard) |
- |
Policy-Based Mapping/Overwriting of DiffServ code |
|
- |
VCCI Class A (Japan EMC standard) |
|
points, .1p priority |
|
- |
AS/NZS 3548 (Australia EMC standard) |
- |
DLCS (Dynamic Link Context System, WINS snooping) |
|
- |
EN 55022 Class A (European EMC standard) |
|
for integration with EPICenter Policy Manger |
|
- |
CISPR 22 Class A (European EMC standard) |
VLANs |
|
- |
EN 50082-1:1997 includes ENV 50204 |
- |
IEEE 802.1Q VLAN Tagging |
|
|
(European EMC standards) |
- |
IEEE 802.3ad Static configuration and dynamic (LACP) |
|
- |
EN 55024:1998 includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 |
- |
IEEE 802.1v VLAN classification by Protocol and Port |
|
|
(European EMC standards) |
- |
Port-based VLANs |
|
- |
EN 61000-3-2,3 (European EMC standards) |
- |
MAC-based VLANs |
|
- |
CNS 13438 Class A (BSMI-Taiwan) |
- |
Protocol-sensitive VLANs |
|
- |
Low Voltage Directive (LVD) |
- |
Multiple STP domains per VLAN |
|
Requirements |
- |
RFC-3069 VLAN Aggregation |
|
- |
Operating Temperature: 0° to 40°C (32° to 104°F) |
- |
Virtual MANs |
|
- |
Storage Temperature: -40° to 70°C (-40° to 158°F) |
- |
VLAN Translation |
|
- |
Operating Humidity:10%to 95%relative humidity, |
RIP |
|
|
non-condensing |
- |
RFC 1058 RIP v1 |
|
- |
EN60068 to Extreme IEC68 schedule |
- |
RFC 2453 RIP v2 |
|
Reliability |
|
|
|
- |
Minimum 50000 hrs MTBF to Mil HDBK 217F |
|
|
|
|
Notice 1, Parts Stress Method |