Shielded Twisted Pair Cable (FTP), 10/25/50/100 pairs, Solid, Indoor (Category 3)

Specifications:
Meets EIA/TIA 568-B for category 3 requirements
Fire protection – CM
The cable meets IEC 60332-1 fire safety standard

Description:
Shielded Copper cable, 10/25/50/100 pairs, category 3, solid
Shield – aluminum foil
Cable is used for indoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC
An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 5 mm (0.19")

Electrical characteristics:
Max DC Resistance at 20°C (68°F) 9.38 Ohm/100 m (2.86 Ohm/100 ft)
Max Resistance Unbalance 3%
Max Capacitance unbalance – pair-to-ground at 1kHz 330 pF/100 m (101 pF/100 ft)
Characteristic Impedance at 1-16 MHz 85-115 Ohm
Max attenuation at 20°C (68°F) and at 64 kHz
Up to 10 MHz 
At 16 MHz

12 dB
10 dB
Max attenuation at 20°C (68°F) 
At 772 kHz 
At 1 MHz 
At 4 MHz 
At 8 MHz 
At 10 MHz 
At 16 MHz

2.2 dB/100 m (0.67 dB/100 ft) 
2.6 dB/100 m (0.79 dB/100 ft) 
5.6 dB/100 m (1.71 dB/100 ft) 
8.5 dB/100 m (2.59 dB/100 ft) 
9.7 dB/100 m (2.96 dB/100 ft) 
13.1 dB/100 m (3.99 dB/100 ft)
Min worst pair to pair NEXT loss at 772 kHz 
At 772 kHz 
At 1 MHz 
At 4 MHz 
At 8 MHz 
At 10 MHz 
At 16 MHz

43 dB
41 dB
32 dB
27 dB
26 dB
23 dB
Min Relative Velocity of Propagation àt 10 MHz 0.585


10 pairs


Shielded twisted pair cable FTP, category 3, 10 pairs, solid 

1 – Jacket
2 – Rip-cord
3 – Shield-foil
4 – Drain wire
5 – Protective skin
6 – Polymer tape
7 – Solid twisted pair

Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 8 mm (0.31")
Jacket thickness: 0.7 mm (0.027")
Maximum strand pitch: 150 mm (5.9")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Drain wire diameter: 0.5 mm (0.019")
Installation temperature: -5°C – +50°C (+22°F – +122°F)
Operating temperature: -20°C – +50°C (-4°F – +122°F)
Weight per 1000 ft (304.8 m): 21.3 kg (47 lbs)
Standard package: 1000 m (3280 ft)


25 pairs


Shielded twisted pair cable FTP, category 3, 25 pairs, solid 

1 – Jacket
2 – Rip-cord
3 – Shield-foil
4 – Drain wire
5 – Protective skin
6 – Polymer tape
7 – Solid twisted pair

Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 11.5 mm (0.45")
Jacket thickness: 1 mm (0.039")
Maximum strand pitch: 150 mm (5.9")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Drain wire diameter: 0.5 mm (0.019")
Installation temperature: -5°C – +50°C (+22°F – +122°F)
Operating temperature: -20°C – +50°C (-4°F – +122°F)
Weight per 1000 ft (304.8 m): 49.4 kg (108.9 lbs)
Standard package: 1000 m (3280 ft)


50 pairs


Shielded twisted pair cable FTP, category 3, 50 pairs, solid 

1 – Jacket
2 – Rip-cord
3 – Shield-foil
4 – Drain wire
5 – Protective skin
6 – Polymer tape
7 – Solid twisted pair

Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 15 mm (0.59")
Jacket thickness: 1 mm (0.039")
Maximum strand pitch: 150 mm (5.9")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Drain wire diameter: 0.5 mm (0.019")
Installation temperature: -5°C – +50°C (+22°F – +122°F)
Operating temperature: -20°C – +50°C (-4°F – +122°F)
Weight per 1000 ft (304.8 m): 93 kg (205 lbs)
Standard package: 500 m (1640 ft)


100 pairs


Shielded twisted pair cable FTP, category 3, 100 pairs, solid 

1 – Jacket
2 – Rip-cord
3 – Shield-foil
4 – Drain wire
5 – Protective skin
6 – Polymer tape
7 – Solid twisted pair

Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 22 mm (0.86")
Jacket thickness: 1.5 mm (0.059")
Maximum strand pitch: 150 mm (5.9")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Drain wire diameter: 0.5 mm (0.019")
Installation temperature: -5°C – +50°C (+22°F – +122°F)
Operating temperature: -20°C – +50°C (-4°F – +122°F)
Weight per 1000 ft (304.8 m): 173.7 kg (383 lbs)
Standard package: 500 m (1640 ft)

Ordering:
FTPXX-C3-SOLID-INDOOR Shielded twisted pair cable (FTP), 10/25/50/100 pairs, category 3, solid, indoor

XX – quantity of pairs: 10, 25, 50, 100 pairs

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 